MRI衍生影像组学和端到端深度学习模型预测胶质瘤ATRX状态:诊断测试准确性研究的系统综述和荟萃分析
MRI-derived radiomics and end-to-end deep learning models for predicting glioma ATRX status: a systematic review and meta-analysis of diagnostic test accuracy studies.
MRI-derived radiomics and end-to-end deep learning models for predicting glioma ATRX status: a systematic review and meta-analysis of diagnostic test accuracy studies.
我们旨在系统评价并荟萃分析磁共振成像(MRI)衍生的影像组学/端到端深度学习(DL)模型在预测胶质瘤α地中海贫血/智力障碍综合征X连锁(ATRX)状态方面的预测价值。我们全面检索了四个主要数据库——Web of Science、PubMed、Scopus和Embase。所有评估影像组学和/或端到端DL模型预测胶质瘤ATRX状态性能的研究均被纳入。采用诊断准确性研究质量评价-2(QUADAS-2)标准和影像组学方法学评分(METRICS)进行质量评价。计算性能指标的合并估计值。采用I平方评估异质性,同时进行亚组分析和敏感性分析以寻找其潜在来源。采用Deeks'漏斗图评估发表偏倚。系统评价和荟萃分析分别纳入17项和11项研究。根据QUADAS-2,大多数研究具有低偏倚风险和低适用性担忧。此外,根据METRICS,大多数研究质量良好。荟萃分析显示合并灵敏度为0.80(95%CI:0.71-0.96),特异度为0.82(95%CI:0.67-0.93),阳性诊断似然比(DLR)为6.77(95%CI:4.67-9.82),阴性DLR为0.15(95%CI:0.06-0.38),诊断比值比为30.36(95%CI:15.87-58.05),曲线下面积(AUC)为0.92(95%CI:0.89-0.94)。亚组分析揭示了基于若干因素的显著组间差异。影像组学模型能够准确预测胶质瘤中的ATRX状态,增强非侵入性肿瘤表征并指导治疗策略。
We aimed to systematically review and meta-analyze the predictive value of magnetic resonance imaging (MRI)-derived radiomics/end-to-end deep learning (DL) models in predicting glioma alpha thalassemia/mental retardation syndrome X-linked (ATRX) status. We conducted a comprehensive search across four major databases-Web of Science, PubMed, Scopus, and Embase. All the studies that assessed the performance of radiomics and/or end-to-end DL models for predicting glioma ATRX status were included. Quality assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) criteria and the METhodological RadiomICs Score (METRICS). Pooled estimates for performance metrics were calculated. I-squared was used to assess heterogeneity, while subgroup and sensitivity analyses were performed to find its potential sources. Publication bias was assessed using Deeks' funnel plots. Seventeen and eleven studies were included in the systematic review and meta-analysis, respectively. Most of the studies had a low risk of bias and low concern for applicability according to the QUADAS-2. Also, most of them had good quality according to the METRICS. Meta-analysis showed a pooled sensitivity of 0.80 (95%CI: 0.71-0.96), a specificity of 0.82 (95%CI: 0.67-0.93), a positive diagnostic likelihood ratio (DLR) of 6.77 (95%CI: 4.67-9.82), a negative DLR of 0.15 (95%CI: 0.06-0.38), a diagnostic odds ratio of 30.36 (95%CI: 15.87-58.05), and an area under the curve (AUC) of 0.92 (95%CI: 0.89-0.94). Subgroup analysis revealed significant intergroup differences based on several factors. Radiomics models can accurately predict ATRX status in gliomas, enhancing non-invasive tumor characterization and guiding treatment strategies.
Amir Mahmoud Ahmadzadeh, Nima Broomand Lomer, Mohammad Amin Ashoobi, Girish Bathla, Houman Sotoudeh. MRI-derived radiomics and end-to-end deep learning models for predicting glioma ATRX status: a systematic review and meta-analysis of diagnostic test accuracy studies.. Clinical imaging. 2024; doi:10.1016/j.clinimag.2024.110386.
Amir Mahmoud Ahmadzadeh, Nima Broomand Lomer, Mohammad Amin Ashoobi, Girish Bathla, Houman Sotoudeh (2024). MRI-derived radiomics and end-to-end deep learning models for predicting glioma ATRX status: a systematic review and meta-analysis of diagnostic test accuracy studies.. Clinical imaging. https://doi.org/10.1016/j.clinimag.2024.110386
Amir Mahmoud Ahmadzadeh, Nima Broomand Lomer, Mohammad Amin Ashoobi, Girish Bathla, Houman Sotoudeh. MRI-derived radiomics and end-to-end deep learning models for predicting glioma ATRX status: a systematic review and meta-analysis of diagnostic test accuracy studies.[J]. Clinical imaging, 2024 doi:10.1016/j.clinimag.2024.110386.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出