Journal of Prosthodontic Research口腔修复研究杂志
Journal of Prosthodontic Research(英文缩写 J PROSTHODONT RES),ISSN 1883-1958,eISSN 2212-4632,中文译名:口腔修复研究杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 4.338 | Q1 |
| 2022 | 3.600 | Q1 |
| 2023 | 3.200 | Q1 |
| 2024 | 3.400 | Q1 |
| 2025 | 3.800 | Q1 |
Journal of Prosthodontic Research 最新收录文献
-
1. Bonding performance and hydrolytic durability of zirconia treated with a hydrophobic long-chain silane in combination with MDP-containing luting agents.
1. 含MDP粘接剂与疏水性长链硅烷联合处理氧化锆的粘接性能及水解耐久性PMID:日期:2026-10-03To evaluate the effects of hydrophobic long-chain silane 8-methacryloxyoctyl trimethoxy silane (8-MOTS) on the bonding performance and hydrolytic durability of alumina-abraded zirconia with various luting agents. Zirconia specimens were airborne-particle-abraded with alumina and treated with 1.0% 8-MOTS, 0.5% 8-MOTS, 1.0% 3-(trimethoxysilyl) propyl methacrylate (3-TMSPMA), KATANA Cleaner, or no primers. Three luting agents (G-Cem One, methacryloyloxydecyl dihydrogen phosphate (MDP) only; PANAVIA SA Cement Universal, MDP, and silane; DUO-LINK Universal, without MDP and silane) were used for bonding. An additional DUO-LINK Universal group was treated with Z-Prime Plus. Shear bond strength (SBS) was measured after 24 h of water storage and 16 h of boiling (n = 8 each). Contact angles and debonded surfaces were also evaluated. After boiling, 1.0% 8-MOTS maintained a significantly higher SBS than 1.0% 3-TMSPMA and primer-free conditions in G-Cem One (P = 0.0005). The effect of the external 8-MOTS was limited in PANAVIA SA Cement Universal and DUO-LINK Universal. In DUO-LINK Universal, both Z-Prime Plus and KATANA Cleaner maintained higher residual SBS than the primer-free condition. The high-SBS group generally exhibited more residual luting agents on the zirconia, whereas the low-SBS group predominantly showed exposed zirconia surfaces. The benefit of 8-MOTS was most evident in G-Cem One, in which 1.0% 8-MOTS maintained a higher zirconia bond strength after hydrothermal aging than 3-TMSPMA or no primers. These findings indicate that the effect of 8-MOTS depends on luting agent composition and represents secondary stabilization within a compatible MDP-containing bonding framework.
-
2. Intraoral scanning for immediate denture fabrication in a patient with an unstable fixed prosthesis and severe tooth mobility: A case report.
2. 口内扫描用于固定修复体不稳定且牙齿严重松动的患者即刻义齿制作:一例病例报告PMID:日期:2026-10-03Conventional impression taking for immediate denture fabrication may pose substantial risks to patients with unstable fixed prostheses or severely mobile teeth. This case report describes the use of an intraoral scanner (IOS) to obtain digital impressions and interocclusal records in a 74-year-old woman with an unstable maxillary full-arch fixed prosthesis and non-salvageable abutment teeth, which carry a substantial risk of prosthesis dislodgement, unintended extraction, or loss of the pre-extraction interocclusal relationship. Digital impressions were obtained without removing the failing prosthesis, and interocclusal records were acquired at the existing intercuspal position to preserve the pre-extraction occlusal relationship. The teeth planned for extraction were digitally removed using computer-aided design software, and the working casts were fabricated by three-dimensional printing. An immediate complete maxillary denture is conventionally fabricated on a duplicated gypsum cast and delivered immediately after prosthesis removal and tooth extraction. Throughout the treatment, the digital approach preserved the pre-extraction occlusal relationship, avoided an edentulous interval, and supported oral function and patient comfort. The clinical contribution of this report lies in demonstrating the practical value of intraoral scanning in high-risk situations involving unstable prostheses and severe tooth mobility. Within the limitations of a single case, digital impression and interocclusal recording with an IOS may be useful options for immediate denture fabrication in patients with unstable prostheses and severe tooth mobility, particularly when preserving the pre-extraction occlusal relationship and avoiding prosthesis dislodgement or unintended extraction are clinically important.
-
3. Effects of chemical surface treatment on shear bond strength between additively manufactured denture base and autopolymerizing resins in non-aged conditions.
3. 化学表面处理对未老化条件下增材制造义齿基托与自凝树脂间剪切粘接强度的影响PMID:日期:2026-10-03This study aimed to clarify the effects of chemical surface treatment of denture base resin on the shear bond strength between denture base resin fabricated by additive manufacturing and autopolymerizing resin in non-aged conditions. Five surface-treatment conditions were applied to specimens fabricated from two additively manufactured resins (AM 1 and AM 2): no treatment (NT); application of a dichloromethane-containing resin primer for 5 s (M5s), 60 s (M60s), or 120 s (M120s); and application of an ethyl acetate-containing resin primer for 120 s (E120s). Three surface-treatment conditions (NT, M5s, and E120s) were applied to control specimens fabricated from autopolymerizing denture base resin. The autopolymerizing resin was bonded to each specimen after chemical surface treatment. The shear bond strength was measured, and the failure modes on the specimen surfaces were observed. The highest median shear bond strength was 16.8 MPa for the AM 1 specimens in M60s, 16.7 MPa for the AM 2 specimens in M5s, and 17.2 MPa for the autopolymerizing resin specimens in M5s. Substrate failure was observed in AM 1 specimens following M60s treatment. Cohesive failure was observed in AM 2 specimens following M5s treatment. Under non-aged conditions, chemical surface treatment of additive manufacturing resins with a dichloromethane-containing resin primer improved the shear bond strength to the autopolymerizing resin. Furthermore, the most effective application time of the dichloromethane-containing primer varied depending on the type of additive manufacturing denture base resin.
-
4. Model-free digital-correction workflow for multi-implant restorations: A clinical proof-of-concept study.
4. 多颗种植修复体的无模型数字化校正工作流程:一项临床概念验证研究PMID:日期:2026-09-14This clinical proof-of-concept study evaluates the feasibility and accuracy of a digital workflow for fabricating and correcting implant-supported restorations of multiple dental implants in an edentulous maxilla using intraoral scanning and reverse-scan bodies. An intraoral scan (IOS) was performed using vertical scan bodies in one patient with four implants in the edentulous maxilla. Ten verification bars (VB) were fabricated and clinically assessed. Nonpassive VBs were sectioned and reconnected intraorally (splinted verification bars, SVBs) and then scanned using reverse-scan bodies and a laboratory scanner. New verification bars (NVB) were fabricated based on these data. The linear and angular deviations between the implants were analyzed across the IOS, VBs, SVBs, and NVBs. Statistical analysis included Welch's ANOVA and post hoc testing (α = 0.05). None of the VBs achieved a clinically passive fit. IOS-VB comparisons showed mean linear deviations of 14-77 µm, with four measurements >100 µm. Mean deviations between VBs and SVBs ranged from 35 to 173 µm, with 20 measurements >100 µm. In contrast, SVB-NVB mean deviations ranged from 4 to 27 µm, with only one >100 µm. All NVBs demonstrated a clinically passive fit and no significant differences were observed between the SVBs and NVBs (P > 0.05). Under the specific conditions of this proof-of-concept study, a combined digital-correction workflow using reverse-scan bodies and integrated titanium base abutments achieved clinically acceptable outcomes. However, multiple variables were modified simultaneously; therefore, the contribution of each step to the final passive fit could not be isolated.
-
5. Artificial intelligence in dental clinical decision support: Concept, challenges, and progress.
5. 人工智能在牙科临床决策支持中的应用:概念、挑战与进展PMID:日期:2026-09-08In this review, we propose and elaborate on the conceptual framework of "decision support intelligence" (DSI) in dentistry. We aimed to define DSI as the intelligent execution of evidence-based clinical decision trees, outline a preliminary implementation pathway, identify key technical challenges hindering its development, and summarize the current research progress across major dental specialties to guide future artificial intelligence (AI) integration in clinical decision-making. We searched for studies using major databases including PubMed, Web of Science, and IEEE Xplore, to construct a coherent conceptual framework and illustrate the key arguments. The transition toward intelligent dentistry remains incomplete, with "operational intelligence" maturing while DSI lags. This review is the first to report the core concept of DSI as an intelligent execution of decision trees that simulate clinical reasoning. It outlines the preliminary implementation strategies and key developmental challenges. This review may accelerate the translation of AI from research to practical clinical tools, ultimately supporting dentists in making more standardized, efficient, and evidence-based decisions, reducing workload, and minimizing errors, particularly in resource-variable settings.
-
6. Flexural strength and flexural modulus of repaired 3D-printed denture base resin: Effects of reinforcement and thermal cycling.
6. 修复后3D打印义齿基托树脂的弯曲强度和弯曲模量:增强和热循环的影响PMID:日期:2026-09-08This study evaluated the effects of reinforcement materials and thermal cycling (TC) on the flexural strength and modulus of repaired three-dimensional (3D)-printed denture base resin. Specimens were fabricated from a 3D-printed denture base resin and assigned to five groups: positive control (PC; intact), negative control (NC; repaired with autopolymerizing resin only), metal repair (MR), fiber repair-thin (FR-thin), and fiber repair-thick (FR-thick). Each group was further subdivided into no TC (NTC) and TC (10,000 cycles) conditions. Flexural strength and modulus were measured using a three-point bending test. Data (n = 10 per group) were analyzed using nonparametric statistical methods (α = 0.05). Under both NTC and TC conditions, the NC group exhibited the lowest flexural strength and modulus (P < 0.05). The FR-thick group demonstrated the highest flexural strength and modulus, and after TC, its flexural strength was comparable to that of the PC group (P > 0.05). Failure mode analysis showed complete fractures in the PC and NC groups, whereas the MR and FR-thick groups consistently exhibited incomplete fractures regardless of TC. TC significantly reduced the flexural strength and modulus in all groups except the FR-thin group (P < 0.05). Thick glass fiber reinforcement yielded the greatest improvement in the flexural strength and modulus of the tested vat-photopolymerization-based 3D-printed denture base resin after repair. Following TC, the flexural strength of the FR-thick group was comparable to intact specimens, and its flexural modulus remained the highest among all groups.
-
7. Dental prosthetic treatment outcomes in patients with xerostomia and hyposalivation: A scoping review.
7. 口腔干燥和唾液分泌不足患者的牙科修复治疗结果:范围综述PMID:日期:2026-09-08This scoping review aimed to map the association between xerostomia and/or hyposalivation and dental prosthetic treatment outcomes and identify knowledge gaps. Two reviewers independently searched the PubMed and Scopus databases in accordance with the PRISMA extension for Scoping Reviews (PRISMA-ScR). Studies involving patients (≥18 years) with xerostomia and/or hyposalivation who underwent prosthetic treatment were included. Randomized controlled trials, cohort studies, cross-sectional studies, and case series with 10 or more cases were eligible. Results were synthesized narratively. Thirty-three studies were included. For implant-supported prostheses, implant survival rates in patients with xerostomia and/or hyposalivation were generally high. In patients with radiation-induced hyposalivation, greater xerostomia severity and higher radiation doses at the implant site were associated with implant failure in individual observational studies. For removable dentures, xerostomia and/or hyposalivation were consistently associated with lower patient and masticatory satisfaction, and impaired function. However, denture adhesives improved retention in patients with hyposalivation. For fixed restorations, limited evidence from a single retrospective cohort study has suggested an increased risk of restoration failure. Subjective xerostomia perception was more strongly associated with oral health-related quality of life than the objective salivary flow rate. Although dental implants generally achieve high survival rates in patients with xerostomia and/or hyposalivation, they may be impaired by certain conditions such as radiation dose at the implant site. These findings are predominantly based on short- to medium-term observations, and comprehensive biological or functional success remains insufficiently examined. Significant knowledge gaps persist, and well-designed clinical studies are required to establish evidence-based treatment strategies.
-
8. Load distribution for screw-retained fixed dental prostheses with different implant-abutment connection: A nonlinear finite element analysis.
8. 不同种植体-基台连接方式下螺丝固位固定牙科修复体的负载分布:一项非线性有限元分析PMID:日期:2026-08-27[中文摘要] 本非线性有限元分析研究旨在评估两种不同的种植体-修复体连接方式对种植体组件及骨组织应力分布以及种植体-基台-修复体界面位移的影响。建模过程中采用了两种不同的种植体-修复体连接方式(间接连接和直接连接),并设计了两个种植体支持的远中三单位悬臂修复体及其周围骨组织。间接种植体-修复体连接在种植体、基台、帽和咬合螺丝组件之间定义了非线性摩擦接触,直接种植体-修复体连接在种植体、基台和螺丝组件之间定义了非线性摩擦接触。在四种不同加载条件下,分别对修复体施加垂直力和斜向力。研究评估了Von Mises应力的大小和分布以及位移特征。斜向加载条件导致种植体-基台复合体的应力和位移值增加。尤其是在直接种植体-修复体连接中,螺丝和种植体的应力值明显更高。间接连接的螺丝中观察到最大位移,直接连接的基台中观察到最大位移。连接设计可能影响种植体-基台复合体及周围骨组织内的应力、应变和位移。不同类型的种植体-修复体连接可能导致这些生物力学参数的差异。需要进一步的临床研究来评估这些发现的临床意义。
[英文摘要] The purpose of this nonlinear finite element analysis study was to assess the impact of two different implant-restoration connection types on stress distribution at implant components and bone as well as displacement at the implant-abutment-restoration interface. Two different implant-restoration connection types (indirect and direct) were utilized in the modeling process, and two implant-supported distal 3-unit cantilevered restorations with surrounding bone were designed. Nonlinear friction contact was defined between the implant, abutment, cap, and occlusal screw components for indirect implant-restoration connection and between the implant, abutment, and screw components for direct implant-restoration connection. Vertical and oblique forces were applied separately to the restorations under four different loading conditions. The study assessed both the magnitude and distribution of the Von Mises stresses, as well as the characteristics of displacement. Oblique load conditions resulted in increased stress and displacement values at the implant-abutment complex. Especially in the direct implant-restoration connection, the stress values in the screws and implants were notably higher. The highest displacement was observed in the screws for the indirect connection and in the abutments for the direct connection. Connection design may influence stress, strain, and displacement within the implant-abutment complex and surrounding bone. Different types of implant-restoration connections may lead to variations in these biomechanical parameters. Further clinical studies are required to evaluate the clinical relevance of these findings.
-
9. Periodontal tissue responses following vertical root fracture repair with 4-META/MMA-TBB resin mixed with nano-hydroxyapatite.
9. 混合纳米羟基磷灰石的4-META/MMA-TBB树脂修复垂直根折后的牙周组织反应PMID:日期:2026-08-27[中文摘要] 垂直根折(VRF)修复由于牙周再生能力差,临床上仍具有挑战性,常导致持续性深牙周袋和愈合不良。本研究旨在通过大鼠模型评估使用4-甲基丙烯酰氧乙基偏苯三酸酐/甲基丙烯酸甲酯三正丁基硼烷(4-META/MMA-TBB)树脂水门汀(Super-Bond,SB)及掺入纳米羟基磷灰石的SB(naHAp/SB)修复VRF后的牙周组织反应。在Sprague-Dawley大鼠双侧上颌第一磨牙诱导VRF,每处骨折采用两种材料之一进行修复,随后行牙再植。再植后2、4、6周通过电子探针显微分析(EPMA)、组织学分析及针对osterix(OSX)、骨钙素(OCN)和骨膜蛋白(POSTN)标志物的免疫组化评估牙周组织反应。EPMA显示naHAp/SB组材料-组织界面附近有强烈的钙、磷沉积;相反,SB组仅观察到微弱的钙、磷信号。组织学分析显示naHAp/SB组在整个研究期间持续表现为轻微炎症反应;SB组早期表现为轻至中度炎症,随时间逐渐消退。与SB相比,naHAp/SB组在所有时间点OSX表达均显著升高(P < 0.01),6周时OCN表达显著升高(P < 0.01),4周时POSTN表达显著升高(P < 0.01)。掺入naHAp可显著增强体内成骨反应,并为VRF修复后的牙周愈合创造更有利的环境。
[英文摘要] Vertical root fracture (VRF) repair remains clinically challenging because of poor periodontal regenerative capacity, often leading to persistent deep periodontal pockets and impaired healing. This study aimed to evaluate periodontal tissue responses after VRF repair using 4-methacryloxyethyl trimellitate anhydride/methyl methacrylate tri-n-butylborane (4-META/MMA-TBB) resin cement (Super-Bond, SB) and nano-hydroxyapatite (naHAp)-incorporated SB (naHAp/SB) in a rat model. VRFs were induced in both maxillary first molars of Sprague-Dawley rats. Each fracture was repaired with one of the two materials, followed by tooth replantation. Periodontal tissue responses were assessed using electron probe microanalysis (EPMA), histological analysis, and immunohistochemistry targeting osterix (OSX), osteocalcin (OCN), and periostin (POSTN) markers at 2, 4, and 6 weeks post-replantation. EPMA showed strong calcium and phosphorus deposition near the material-tissue interface in the naHAp/SB group. Conversely, only weak calcium and phosphorus signals were observed in the SB group. Histological analysis showed that the naHAp/SB group consistently exhibited minimal inflammatory responses throughout the study period. The SB group exhibited early mild-to-moderate inflammation, which gradually subsided over time. Compared with SB, the naHAp/SB group showed significantly higher expression of OSX at all time points (P < 0.01), OCN at 6 weeks (P < 0.01), and POSTN at 4 weeks (P < 0.01). Incorporating naHAp significantly enhanced osteogenic responses and created a more favorable environment for periodontal healing after VRF repair in vivo.
-
10. Relationship between lifestyle diseases and oral function in older adults: The Toon Health Study.
10. 老年人生活方式疾病与口腔功能的关系:东温健康研究PMID:日期:2026-08-13Lifestyle diseases are established risk factors for oral function decline; however, the age-dependent dynamics of these associations, specifically between "young-old" and "old-old" phases, remain unclear. This study investigated the relationship between six major lifestyle diseases and seven oral function measures across age strata to identify the critical windows for medical and dental intervention. This cross-sectional analysis within the "Toon Health Study" recruited 395 community-dwelling individuals (mean age 68.8 ± 8.9 years), stratified into middle-aged, young-old, and old-old groups. Systemic status and oral function were evaluated using standard diagnostic criteria. Associations were analyzed using logistic regression models adjusted for age, sex, and family dentist status. The predicted probability plots visualized age-dependent associations. Logistic regression analysis revealed age-dependent associations between diabetes mellitus (DM) and oral hypofunction. Although DM showed a protective association in the old-old group (odds ratio [OR] = 0.28, P = 0.014), it significantly increased the risk of oral hypofunction in the young-old group (OR = 7.75, P = 0.003). Decreased masticatory function was significantly associated with DM and obesity (P < 0.05). Although these conditions increased the risk of decreased masticatory function in the young-old group, none of the participants with DM in the old-old group exhibited such an impairment. DM and OBE may exacerbate oral function decline in young-old individuals more strongly than aging itself, whereas continuous dental care may mitigate these effects in the old-old. This highlights the importance of integrating age-specific oral management with lifestyle disease prevention.