ADVANCES IN STRUCTURAL ENGINEERING结构工程进展
ADVANCES IN STRUCTURAL ENGINEERING(英文缩写 ADV STRUCT ENG),ISSN 1369-4332,eISSN 2048-4011,中文译名:结构工程进展 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 2.438 | Q3 |
| 2022 | 2.600 | Q2 |
| 2023 | 2.100 | Q2 |
| 2024 | 2.600 | Q2 |
| 2025 | 2.500 | Q2 |
ADVANCES IN STRUCTURAL ENGINEERING 最新收录文献
-
1. Nonlinear tensile behavior of ±55˚ concrete-filled GFRP tubes: Experimental and theoretical studies.
1. ±55˚混凝土填充GFRP管的非线性拉伸行为:实验与理论研究PMID:日期:2025-10-30[中文摘要] 带角度铺层构型的混凝土填充纤维增强聚合物(FRP)管(CFFTs),如±55°玻璃纤维增强聚合物(GFRP)管,表现出传统正交铺层管无法捕捉的强非线性行为。一个关键挑战在于捕捉其拉伸状态下的失效应变,因为大变形使得传统仪器难以进行精确测量。本研究通过引入一种新型试验构型来应对这一挑战,该构型能够在纯轴向拉伸下捕捉填充混凝土的±55° GFRP管(±55° CFFTs)的拉伸响应。研究进行了一项仪器配置完善的±55° CFFT梁试验,首次记录了0.077 mm/mm的极限拉伸应变。为补充实验,开发了非线性有限元(FE)模型以模拟±55° CFFTs的拉伸行为。模型成功再现了非线性响应,与实验结果的偏差仅为3%-4%。在此基础上,专门针对±55° GFRP管制定了面向设计的本构拉伸方程,随后建立了纳入该方程的分析模型以预测±55° CFFT梁的弯矩承载力,并通过对多项实验梁试验的验证证明了较强的预测精度(极限荷载和挠度的吻合度为85%-100%),较现有模型有实质性改进。
[英文摘要] Concrete-filled fiber-reinforced polymer (FRP) tubes (CFFTs) with angle-ply configurations, such as ±55˚ glass-FRP (GFRP) tubes, show highly nonlinear behavior that is not captured by conventional cross-ply tubes. A key challenge has been capturing their failure strains under tension, since large deformations have prevented accurate measurements with conventional instrumentation. This study addresses this challenge by introducing a novel test configuration capable of capturing the tensile response of ±55˚ GFRP tube filled with concrete (±55˚ CFFTs) under pure axial tension. A well-instrumented ±55˚ CFFT beam test was conducted, which recorded ultimate tensile strain of 0.077 mm/mm for the first time. To complement the experiments, nonlinear finite element (FE) models were developed to simulate ±55˚ CFFTs tensile behavior. The models successfully reproduced the nonlinear response with only 3%-4% variance from experimental results. Building on these findings, a design-oriented constitutive tension equation was formulated specifically for ±55˚ GFRP tubes, and an analytical model incorporating this equation was then established to predict the moment capacity of ±55˚ CFFT beams, and validation against multiple experimental beam tests demonstrated strong predictive accuracy (85%-100% agreement in ultimate load and deflection), representing a substantial improvement over existing models.
-
2. Machine learning-based prediction of tensile strength of glass fiber-reinforced polymer rebar under environmental conditions.
2. 基于机器学习的玻璃纤维增强聚合物钢筋在环境条件下的抗拉强度预测PMID:日期:2025-07-29GFRP rebar is a desirable alternative to steel rebar especially in harsh environments with advantages of light weight, high strength, stable chemical properties, and corrosion resistance. However, there is a lack of understanding on the durability of GFRP rebar which significantly limits its engineering applications. Unfortunately, it is almost impossible to develop any simple theoretical model to predict the residual strength of GFRP rebar after environmental exposure. To effectively address this research gap, this paper investigates machine learning models to predict the residual tensile strength of GFRP rebar due to environmental degradation. Firstly, a database was built from the literature containing a total of 350 tensile testing results of GFRP rebar after experimental exposure. Six key influencing parameters were considered, including fiber content, bar diameter, resin type, exposure temperature, pH, and aging time. Secondly, machine learning models were trained and tested using the database, and the selected models included Decision Tree, Random Forest, Support Vector Machine (SVM), Multilayer Perceptron (MLP), and Long and Short-Term Memory (LSTM) models. The LSTM model demonstrated the best performance in strength prediction, achieving an R of 0.96 on the training set and 0.91 on the testing set. Thirdly, the influencing parameters were ranked using SHAP and Random Forest in terms of their impact on the residual tensile strength of GFRP rebar, and it was found that temperature has the most significant effect followed by fiber content, exposure time, pH and bar diameter, while resin type showed the least importance. Notably, SHAP analysis also showed that the coupling of different parameters also had impact on the residual strength, and the combined effect of fiber content with other parameters was the most prominent. This paper demonstrates the feasibility of machine learning models in the durability study of GFRP composite materials.