Journal of Indian Prosthodontic Society印度口腔修复学会杂志
Journal of Indian Prosthodontic Society(英文缩写 J INDIAN PROSTHODONT),ISSN 0972-4052,eISSN 1998-4057,中文译名:印度口腔修复学会杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 未收录 | N/A |
| 2022 | 1.200 | N/A |
| 2023 | 1.000 | Q3 |
| 2024 | 1.000 | Q4 |
| 2025 | 1.300 | Q3 |
Journal of Indian Prosthodontic Society 最新收录文献
-
1. Design of a novel dental bone mapping caliper for chairside ridge assessment: A technical note.
PMID:日期:2026-10-01Accurate assessment of alveolar ridge width is essential for implant treatment planning. Although cone-beam computed tomography provides detailed three-dimensional information, chairside ridge-mapping techniques remain valuable because of their simplicity, accessibility, and cost-effectiveness. The objective of this study was to describe the design, clinical application, and potential advantages of a novel dental bone mapping caliper for transgingival ridge assessment. The proposed instrument incorporates a blunt external reference arm, a controlled transgingival probing tip, a calibrated sliding measurement scale, and an ergonomically designed handle within a single device. The instrument enables direct chairside measurement of alveolar ridge width while improving stabilization and measurement standardization. The caliper is used during transgingival ridge mapping by positioning the blunt arm against the mucosal surface and advancing the probing tip until cortical bone contact is achieved. Measurements are recorded directly from the calibrated scale. Compared with conventional ridge-mapping methods, the proposed design offers improved operator control, direct measurement recording, enhanced stability, and simplified clinical workflow. However, clinical validation studies are required to determine its accuracy, reproducibility, and patient acceptance. The novel dental bone mapping caliper represents a practical chairside tool for ridge assessment and may improve the standardization of transgingival bone mapping procedures. Further clinical investigations are necessary to establish its effectiveness relative to existing methods.
-
2. Maxillofacial prosthetic management of oral incompetence following commando surgery and partial maxillectomy: A clinical report.
PMID:日期:2026-10-01Extensive oncologic resection in the maxillofacial region frequently results in functional deficits that compromise oral competence and patient quality of life. The present clinical report describes a patient who underwent commando surgery with partial maxillectomy and reconstruction using a pectoralis major myocutaneous flap following treatment for squamous cell carcinoma. The patient presented with an extensive facial defect, inadequate mouth closure, persistent salivary drooling, tissue exposure and discomfort during routine activities. A custom facial shield prosthesis was fabricated to provide passive external support and protect the reconstructed tissues. A lightweight clear acrylic prosthesis was designed to conform to the postoperative facial contours. Following insertion, the prosthesis provided passive coverage and support of the reconstructed tissues, with satisfactory clinical adaptation and patient-reported acceptance. Because comfort and salivary leakage were assessed only descriptively, these observations were not treated as objective functional outcomes. The primary clinically supported role of the prosthesis was protection of reconstructed tissues during postoperative healing when definitive correction was not feasible.
-
3. Evaluating the impact of print orientation and layer thickness on mechanical properties of three-dimensional-printed denture base resin.
PMID:日期:2026-10-01Layer thickness and print orientation are important printing considerations that influence the mechanical performance of additively manufactured denture base resins. However, evidence regarding their combined effects remains limited. The study investigated the influence of print orientation and layer thickness on the flexural strength, fracture toughness, surface roughness, and impact strength of an additively manufactured digital light processing (DLP) denture base resin. In vitro comparative study. Using a DLP-based three-dimensional printing system, 384 denture base resin specimens were manufactured with three build orientations (0°, 45°, and 90°) and four printing layer heights (25, 50, 75, and 100 µm). Flexural strength and elastic modulus were assessed using a three point bend test, fracture toughness using a pre-notched three point bending test, and Izod impact tester was used to estimate the impact strength. Surface roughness was evaluated with a stylus profilometer, and fractured surfaces were examined using scanning electron microscopy. Two-way analysis of variance and Bonferroni adjusted post hoc comparisons. Both layer thickness and print orientation significantly influenced all tested properties ( P < .001). The highest flexural strength (127.71 ± 1.83 MPa), fracture toughness (1.49 ± 0.02 MPa·m 0 · 5 ), and impact strength (10.58 ± 0.15 kJ/m 2 ) were observed at 25 µm and 45° orientation, whereas the lowest values were recorded at 100 µm and 90°. Surface roughness increased with increasing layer thickness, with the smoothest surface at 25 µm and 0° (Ra = 0.33 ± 0.01 µm) and the roughest at 100 µm and 90° (Ra = 0.95 ± 0.02 µm). Fabrication at 25 µm layer thickness and 45° print orientation provided the most favorable mechanical performance for the additively manufactured DLP denture base resin.
-
4. Marginal and internal adaptation of monolithic computer-aided design and computer-aided manufacturing zirconia crowns and heat-pressed ceramic veneered zirconia crowns: An in vitro study.
PMID:日期:2026-10-01This study aimed to compare the marginal and internal adaptation of monolithic computer-aided design and computer-aided manufacturing (CAD/CAM) zirconia crowns and heat-pressed ceramic-veneered zirconia crowns fabricated using a standardized digital workflow. An in vitro laboratory study was conducted using standardized epoxy resin dies and zirconia crowns fabricated by two different laboratory workflows. Twenty zirconia crowns were fabricated from a single STL dataset with a 50-µm cement space and divided into two groups ( n = 10): monolithic CAD/CAM zirconia (MZ) and bilayer heat-pressed ceramic-on-zirconia (PVZ). All crowns were fabricated on epoxy resin dies replicated from a CAD/CAM-milled stainless-steel master die. After cementation with glass ionomer cement under a controlled seating load of 50 N, the specimens were sectioned buccolingually. Marginal and internal gaps were measured using scanning electron microscopy at eight predetermined sites. Data were evaluated for normality using the Shapiro-Wilk test. Intergroup comparisons were performed using the Mann-Whitney U-test, with statistical significance set at P < 0.05. Bonferroni adjustment was applied for exploratory multiple comparisons. For the primary outcome, composite internal adaptation was lower in the monolithic CAD/CAM zirconia crown group than in the heat-pressed ceramic-veneered zirconia crown group (103.07 vs. 111.38 µm; P = 0.019), with a moderate effect size ( r = 0.53). Composite marginal adaptation did not differ significantly between the groups (88.90 vs. 95.73 µm; P = 0.226). Both fabrication workflows produced zirconia crowns with marginal and internal adaptations within clinically acceptable limits. Monolithic CAD/CAM zirconia crowns showed slightly smaller internal discrepancies than heat-pressed ceramic-veneered zirconia crowns; however, the magnitude of this difference is unlikely to affect clinical seating or cementation.
-
5. In vivo evaluation of the antibacterial efficacy of polyethyleneimine nanoparticle-modified glass ionomer cement versus conventional glass ionomer cement.
PMID:日期:2026-10-01Cemented crowns are susceptible to microleakage over time. Incorporation of quaternized polyethyleneimine (QPEI) nanoparticles into glass ionomer cement (GIC) may enhance its antibacterial properties, potentially increasing crown longevity. Insoluble QPEI nanoparticles exhibit strong antibacterial activity against bacteria in vitro, especially in provisional and orthodontic cements. However, their efficacy under oral conditions remains uncertain. Given the limited evidence under oral conditions, the present study evaluated the antibacterial performance of QPEI-modified GIC in vivo . This exploratory, prospective split-mouth in vivo study was conducted in 16 participants requiring two full veneer crowns in the same arch. Bacterial evaluation was performed after 1 month. Each subject received both interventions on contralateral teeth, thus minimizing inter-individual variability. Patients requiring two fixed prosthetic crowns in the same arch were included. QPEI nanoparticles were synthesized and characterized using nuclear magnetic resonance, Fourier transform infrared, and dynamic light scattering techniques. After tooth preparation, one crown was cemented with conventional GIC and the other with 1% QPEI-modified GIC. After 1 month, marginal cement samples were collected, and bacterial growth was quantified by colony-forming unit (CFU/mL) counts on brain heart infusion agar. Statistical analysis was performed using SPSS software. Data normality was assessed using the Kolmogorov-Smirnov test, and the Wilcoxon signed-rank test was used for intergroup comparison. Paired analysis revealed a statistically significant reduction in viable bacterial counts in the test group, with the Hodges-Lehmann estimator indicating a median reduction of approximately 7.5 × 10 4 CFU/mL (95% confidence interval: -3.2 × 10 4 to -1.4 × 10 4 CFU/mL). Incorporation of 1% QPEI-modified GIC significantly enhanced its antibacterial efficacy in vivo over 1 month, indicating its potential as an antibacterial luting material for fixed prosthodontic restorations.
-
6. Evaluation and comparison of the scanning accuracy of three intraoral scanners for single crown, three-unit, and cross-arch fixed partial denture by three-dimensional digital superimposition technique and measurement of vertical marginal fit of three-dimensional-printed resin retainers: An in vitro study.
6. 通过三维数字叠印技术评估和比较三种口内扫描仪对单冠、三单位及跨牙弓固定局部义齿的扫描精度,以及三维打印树脂固位体的垂直边缘适合性测量:一项体外研究PMID:日期:2026-10-01This study aims to evaluate and compare the scanning accuracy of three IOSs and measuring the vertical marginal fit of three-dimensional (3D) printed resin retainers for single crown, three-unit, and cross-arch fixed partial denture situations. Comparative In Vitro Study. A maxillary Nissin typodont with prepared abutments at #13, #23, #25, #27, and #16 served as the master model. A calibrated Shining 3D laboratory scanner provided the reference standard tessellation language (control). Each IOS generated six scans ( n = 6/scanner; 18 test scans). Trueness and precision were derived by best-fit superimposition in Geomagic Design X. Fifty-four single-unit, three-unit, and cross-arch retainers were 3D-printed. Vertical marginal discrepancy was measured at mid-buccal and mid-lingual sites using a digital stereomicroscope (×20). One-way ANOVA with Tukey's post-hoc test was used for comparisons among scanners and prosthesis spans. Pearson's correlation was used to assess the relationship between trueness and marginal fit, and Chi-square test was used to assess clinical acceptability. A P value ≤0.05 was considered statistically significant. 3Shape TRIOS 3 showed the highest trueness (28.5 ± 5.2 µm) and precision (18.2 ± 3.1 µm), followed by Medit i700 and Shining 3D Aoralscan 3 ( P < 0.001). Marginal discrepancy was lowest with 3Shape TRIOS 3 (52.4 ± 6.5 µm) and increased with span. A positive correlation was found between trueness and marginal fit ( r = 0.82; P < 0.001). Clinical acceptability was 100%, 94.4%, and 77.8% for 3Shape TRIOS 3, Medit i700, and Shining 3D Aoralscan 3, respectively ( P = 0.041). All three scanners delivered clinically acceptable results; 3Shape TRIOS 3 yielded the highest accuracy and best marginal adaptation. Accuracy and marginal fit deteriorated as prosthesis span increased.
-
7. Influence of intraoral and laboratory scanning systems on the marginal fit of direct metal laser-sintered copings: An in vitro study.
7. 口内和实验室扫描系统对直接金属激光烧结基底冠边缘适合性的影响:一项体外研究PMID:日期:2026-10-01This study aimed to evaluate and compare the vertical marginal discrepancy of DMLS copings fabricated from stone dies scanned using an intraoral scanner (IOS) and a laboratory scanner. An in vitro comparative study was conducted to evaluate the influence of intraoral and laboratory scanning systems on the vertical marginal discrepancy of DMLS copings. A customised stainless-steel model simulating a prepared tooth with a shoulder finish line was fabricated. Impressions of the model were made using elastomeric impression material. Forty dies ( n =40) were poured using type IV dental stone and divided into two groups ( n =20). Group 1 dies were scanned using a 3Shape TRIOS IOS and Group 2 dies were scanned using a 3Shape extraoral laboratory scanner. Copings were fabricated using CAD/CAM software. Marginal gap between the die and the coping was measured at 4 predetermined points (buccal, lingual, mesial, and distal) using a stereomicroscope at ×40 magnification. Data were analysed using SPSS (version 21, IBM Corp., Armonk, NY, USA). Student's unpaired t-test was used to compare the tested groups. The collected data were analysed at a significance level set at P < 0.05. The mean marginal gap between the die and coping was 11.44 μm for Group 1 and 29.62 μm for Group 2. The difference between the groups was statistically significant ( P < 0.001). Copings fabricated from dies scanned using IOS demonstrated significantly lower vertical marginal discrepancies compared to those scanned using the laboratory scanner. However, the marginal gaps observed in both groups were within clinically acceptable limits.
-
8. Interobserver reliability and temporal variability of artificial intelligence chatbots in Kennedy-classified removable partial denture design: A cross-sectional analysis.
PMID:日期:2026-10-01This study aimed to investigate the consistency of ratings, the quality of chatbot-generated removable partial denture (RPD) designs, and the repeatability of chatbot outputs over time through standardized Kennedy classification-based RPD design prompts. This study used a cross-sectional design to test the consistency of four AI chatbots among raters (ChatGPT; GPT-4; OpenAI, Copilot 1.25062.106.0; Microsoft, AI Chat-AI language model; DeepAI, Claude AI; Claude 3 Opus; Anthropic) on RPD design for 80 virtual Kennedy-classified cases (40 maxillary/40 mandibular). Eighty partially edentulous virtual cases (Class I, I Mod 2, II, II Mod 1, II Mod 2, III Mod 1, III Mod 2, and IV) were assigned to AI chatbots. Each case was randomly assessed three times daily, resulting in 960 responses evaluated. Four removable prosthodontists scored responses using a modified global quality score based on a five-point Likert scale. Statistical analyses used the intraclass correlation coefficient (ICC) and two-way Analysis of variance ANOVA ( P ≤ 0.05). Interobserver reliability was measured using the ICC, technical quality was compared with an expert consensus reference standard, and repeated-measures ANOVA demonstrated significant temporal variation in chatbot outputs. All chatbots showed excellent interobserver reliability (ICC >0.90), but the resulting RPD designs had lower scores compared with the expert gold reference standards. Repeated-measures analysis indicated significant intra-rater variability across all chatbots ( P < 0.001), suggesting lower repeatability. AI chatbots showed excellent interobserver reliability but limited technical quality and temporal stability in the RPD framework design. ChatGPT (GPT-4; OpenAI) performed best, but all models still need expert supervision and further optimisation before use.
-
9. Stress analysis of mandibular implant-supported overdenture retained with bar and ball attachments of different heights: A comparative finite element study.
PMID:日期:2026-10-01To evaluate and compare stress distribution patterns in mandibular implant-supported overdenture retained with bar and ball attachment systems at two attachment heights (1 mm and 3 mm) using three-dimensional finite element analysis (FEA). An in silico comparative three-dimensional finite element analysis study. Four three-dimensional finite element models of an edentulous mandible restored with two interforaminal bone-level implants (3.5 × 10 mm) were developed. The models incorporated bar attachments with heights of 1 mm (A1) and 3 mm (A2), and ball attachments with heights of 1 mm (B1) and 3 mm (B2). All materials were assumed to be homogeneous, isotropic, and linearly elastic. Complete osseointegration was simulated using bonded contact conditions. A mesh convergence test was performed, and mesh refinement continued until the change in peak von Mises stress between successive mesh refinements was <5%. A static vertical load of 100 N was applied at the central occlusal fossa of the first molar under unilateral and bilateral loading conditions. Stress distribution was evaluated qualitatively and quantitatively using von Mises stress analysis. No statistical analysis was performed. Stress distribution was compared descriptively using qualitative stress distribution patterns and quantitative von Mises stress values generated by the finite element models. Under unilateral loading, stresses were concentrated predominantly on the working side, with the implant neck serving as the principal site of stress concentration. Increasing attachment height increased stress magnitudes in both bar and ball attachment systems under unilateral and bilateral loading conditions. Overall, stress concentrations were greatest at the implant neck, followed by the implant body and apical region. Cortical bone consistently exhibited higher stress values than cancellous bone across all models. Within the limitations of this finite element study, attachment height and splinting configuration influenced peri-implant stress distribution. Increased attachment height was associated with greater stress magnitudes in both attachment systems.
-
10. Etiological trends, defect classification, and prosthetic rehabilitation of maxillofacial defects: A nine-year retrospective institutional analysis.
PMID:日期:2026-10-01The aim of this study was to analyze the distribution of maxillofacial defects with respect to etiology, defect classification, demographic characteristics, and prosthetic treatment modalities over a 9-year period at a tertiary care center. This retrospective study analyzed institutional data from a tertiary care hospital, encompassing patients rehabilitated with maxillofacial prostheses over a 9-year period (2017-2025). Clinical records of patients rehabilitated with maxillofacial prostheses between 2017 and 2025 were reviewed. Data extracted included demographic characteristics, etiology of defects, classification systems (Aramany, Cantor-Curtis, Veau, and Cordeiro), and type of prosthesis delivered. All variables were predefined and uniformly recorded to ensure consistency in data extraction. Data were analyzed using descriptive statistics including frequency and percentage distributions using Microsoft Office Excel (version 2019; Microsoft Corporation, Redmond, WA, USA). Categorical variables were expressed as frequencies and percentages, while continuous variable (age) was summarized using median and interquartile range. Associations between categorical variables were analyzed using Chi-square/Fisher's exact test, and continuous variables across groups were compared using Kruskal-Wallis test with Dunn's post hoc analysis. Statistical analysis was performed using Stata 18.0, with P < 0.05 considered statistically significant. A total of 246 patient records were analyzed, with Aramany-classified maxillary defects constituting the most common defect category (48.0%). Infections were the leading etiological factor (33.3%), followed by trauma (28.9%) and neoplasms (25.6%). Infection- and neoplasm-related defects showed a significant association with Aramany-type maxillary defects ( P = 0.001). Obturator prostheses were the most frequently delivered treatment modality (56.1%). A significant correlation was found between age and maxillofacial defects ( P = 0.04). Smoking (54%) and smokeless tobacco use (24%) were commonly associated risk factors. Acquired maxillofacial defects constituted the majority of cases requiring prosthetic rehabilitation. Infection-related defects, particularly mucormycosis, represented a substantial proportion of cases during the study period, reflecting changing disease patterns observed in the post-coronavirus disease 2019 era. Older age groups demonstrated significantly higher frequencies of malignancy and mucormycosis-related defects. Standardized classification systems facilitated systematic documentation and communication of defect characteristics, while prosthetic rehabilitation was individualized according to the extent of tissue loss, anatomical involvement, and functional requirements. Obturator prostheses remained the most frequently utilized rehabilitation modality for maxillary defects.