Journal of Bronchology & Interventional Pulmonology支气管病学与介入肺脏病学杂志
Journal of Bronchology & Interventional Pulmonology(英文缩写 J BRONCHOL INTERN PU),ISSN 1944-6586,eISSN 1948-8270,中文译名:支气管病学与介入肺脏病学杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 未收录 | N/A |
| 2022 | 3.300 | N/A |
| 2023 | 3.300 | Q2 |
| 2024 | 3.200 | Q2 |
| 2025 | 2.300 | Q3 |
Journal of Bronchology & Interventional Pulmonology 最新收录文献
-
1. Navigation Bronchoscopy Specific Cone-Beam CT Software Enabling Pre- And Intraprocedural Guidance: A Prospective Clinical Feasibility Study.
PMID:日期:2026-09-18Cone-beam computed tomography (CBCT)- guided bronchoscopy is an established technique for diagnosing peripheral pulmonary lesions, offering 3-dimensional imaging for both navigation and confirmation. However, its usability as a stand-alone modality is limited by a substantial learning curve and a lack of integrated planning tools. This study evaluates the feasibility and performance of navigation bronchoscopy-specific CBCT software that enables preprocedural CT-planning fusion with intraprocedural CBCT imaging and provides intraprocedural support algorithms. This prospective, single-center clinical feasibility study exploratively assessed the usability of the AirWaze investigational software. Usability was measured using a standardized system usability score, with scores of 70 or higher considered indicative of good usability (range, 0-100). The performance of the individual software components ('planning,' 'image fusion,' and 'guidance') was evaluated. An ultralow-dose CBCT protocol was compared with conventional CBCT scans for accuracy and radiation exposure. The study enrolled 34 patients with 37 lesions. The investigational software achieved a system usability score of 45. The planning component was available in all cases and was unanimously rated by the endoscopists as accurate and intuitive. In contrast, the image fusion and guidance components were rated as insufficient. The ultralow-dose CBCT protocol provided clinically accurate imaging in 84% of cases and reduced the radiation dose by 94%. Integrating planning and procedural guidance within stand-alone CBCT-guided navigation bronchoscopy procedures has great potential. Although several components of the investigational software were considered valuable, further development is required to ensure comprehensive procedural guidance.
-
2. American Association of Bronchology and Interventional Pulmonology Essential Knowledge in Interventional Pulmonology Series: Advanced Diagnostic Bronchoscopy in Lung Cancer: Closing the Diagnostic Gap and Beyond.
PMID:日期:2026-09-18The American Association of Bronchology and Interventional Pulmonology (AABIP) Essential Knowledge in Interventional Pulmonology Series aims to provide clinicians with concise, up-to-date reviews of key topics in the field, presented on a 3-year rotating cycle. The 2025 series focused on advanced diagnostic bronchoscopy. In this article, we provide an update on the bronchoscopic approach to malignant disease, examining whether navigational bronchoscopy has closed the diagnostic gap with transthoracic needle biopsy for peripheral pulmonary lesions, how advanced bronchoscopic technologies enable integrated diagnosis and mediastinal staging workflows, and whether these clinical benefits translate into meaningful economic value. These reviews are designed to complement the Essential Knowledge in Interventional Pulmonology Lecture Series delivered at the 2025 AABIP Annual Conference, which is available for viewing on the AABIP website: https://aabip.memberclicks.net/essential-knowledge-in-interventional-pulmonology-series.
-
3. The First Pan-African Survey of Interventional Pulmonology: Current Practice, Training Gaps, and Barriers.
PMID:日期:2026-09-03Interventional pulmonology (IP) is essential for managing thoracic diseases, yet its global distribution remains unequal. This study aimed to map IP across Africa by evaluating practice availability, training pathways, and barriers to development. A cross-sectional electronic survey was conducted among interventional pulmonologists practicing in Africa between October and December 2025. Data were collected on institutional IP capacity, technique availability, training background, and perceived obstacles across the 5 African subregions. Fifty-one interventional pulmonologists from 16 countries participated, covering all 5 African subregions. Dedicated IP units were reported by 49.0% of respondents, with availability ranging from 75.0% in Northern Africa to 0.0% in Central Africa. Common techniques included medical thoracoscopy and rigid bronchoscopy (each 80.0%), while radial endobronchial ultrasound remained rare (24.0%). A significant training gap was identified: 49.0% of respondents had no structured IP training, and among those trained, 84.6% received training outside Africa. The primary barrier was equipment lack (34.0%), followed by high costs and training deficits. Despite these challenges, 98% of respondents rated local demand as medium to very high, and 92% of existing units performed procedures weekly, though 39.4% of patients faced wait times exceeding 1 week. Africa faces a significant IP capacity gap driven by regional disparities and structural barriers. Sustainable development will require indigenous training hubs and prioritization of cost-effective technologies to meet growing clinical demand.
-
4. Risk Stratification of Incidental Pulmonary Nodules: A Fully Automated Approach to CT Imaging Analysis.
PMID:日期:2026-09-03Incidental detection is the most common pathway through which pulmonary nodules are identified. With the advancement of navigational and robotic-assisted bronchoscopy, existing risk stratification models often lack sufficient discrimination power, particularly for intermediate-risk nodules. Bronchosolve is a fully automated, imaging-only risk stratification tool that was previously validated in lung cancer screening cohorts. We applied Bronchosolve to a cohort of adults with incidentally detected pulmonary nodules identified from registries at 2 large health care systems between 2006 and 2019. Nodules were classified as malignant or benign based on biopsy or extended clinical follow-up. Discrimination was assessed and compared with the VA Model. Sensitivity and specificity were reported at the Youden and high-sensitivity operating points. Additional analysis was performed in cases with nodule diameter 8 to 15 mm. Among 187 patients, malignancy prevalence was 70%. Bronchosolve achieved an AUC of 0.895 versus 0.870 for the VA model. Among nodules 8 to 15 mm, discrimination differences were larger (AUC 0.808 vs. 0.701). In nodules of 8 to 15 mm in diameter with an intermediate risk for malignancy by the VA model, Bronchosolve reclassified 51 patients to high risk and 23 to low risk; 33/37 (89%) malignancies were up-classified and 19/37 (51%) benign nodules were down-classified. In a nonscreening setting, Bronchosolve demonstrated robust discrimination for lung nodule malignancy risk using imaging alone compared with a widely used clinical risk model, with more pronounced separation in intermediate-sized nodules. In this subgroup, Bronchosolve also yielded clinically meaningful risk reclassification, with potential implications for downstream management.
-
5. Development of a Tool to Assess Competency in Bronchoscopic Lung Volume Reduction Via Endobronchial Valve Placement.
PMID:日期:2026-08-17Bronchoscopic lung volume reduction (BLVR) is an established treatment option for severe emphysema, improving lung function and quality of life. Despite its growing use, there are no standardized, validated tools to assess operator competency in performing BLVR, limiting training and credentialing. To examine the validity of the VSTAT tools, which were designed to assess competency in cognitive and technical skills necessary for BLVR. The Zephyr and Spiration VSTAT tools were used to assess 29 operators with varying levels of experience. Participants were categorized as Beginners, Intermediates, and Experts. Performance was evaluated through simulated scenarios. Scores were analyzed for reliability, validity, and correlation with clinical experience. The tools demonstrated strong internal consistency (Cronbach α=0.88 for Zephyr and 0.77 for Spiration). Significant differences in scores were observed across proficiency levels, with experts outperforming beginners. VSTAT scores correlated strongly with procedural experience (Spearman ρ=0.95 for Zephyr, ρ=0.70 for Spiration). The VSTAT tools provide a reliable and valid method for assessing BLVR competency. Their integration into training programs and certification processes could standardize the assessment of operator competency in BLVR.
-
6. Endobronchial Ultrasound-Guided Fine Needle Biopsy in the Diagnosis of Mediastinal Lymphadenopathy: A Randomized Trial.
PMID:日期:2026-08-17The comparative sampling efficacy of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) needles in mediastinal lymphadenopathy remains unclear. Would the fine needle biopsy (FNB), with its Franseen design, provide better results than the fine needle aspiration (FNA) during EBUS-TBNA? We performed a single-center, investigator-initiated, single-blinded, randomized, parallel-group, superiority trial between August 2022 and July 2023. Consecutive patients were randomly assigned (1:1) to undergo EBUS-TBNA with either 19-gauge (G) FNA or 22-G FNB. The primary endpoint was the diagnostic yield, while the secondary endpoints were specimen adequacy and complication rates. The study included 150 patients with a mean age of 44.5±15.1 years (50.7% female patients). The diagnostic yield of FNB was not significantly different from FNA (94.7% vs. 89.3%; difference, 5.4%; 95% CI: -4.0% to 15.0%; P=0.23). Despite this, FNB had a higher rate of adequate tissue (98.6% vs. 86.7%; difference, 11.9%; 95% CI: 4.0%-22.0%; P<0.001) and larger core tissue (11.52 vs. 9.29 mm; mean difference, 2.23 mm; 95% CI: 1.4-3.1mm; P<0.001) than FNA. FNB showed a significantly higher diagnostic yield for histologic samples (90.7% vs. 76.0%; difference, 14.7%; 95% CI: 3.0-27.0; P=0.016) in post hoc analysis; however, this should be considered a hypothesis-generating finding. All procedures were well tolerated except for minor bleeding. Despite similar diagnostic yields, FNB was more effective than FNA in providing larger, adequate core tissue samples. This improvement in specimen quality may suggest a potential clinical benefit for comprehensive diagnosis and advanced pathologic work-up.
-
7. Hemodynamic Effects of Topical Oxymetazoline During Pediatric Flexible Bronchoscopy.
PMID:日期:2026-08-17Bleeding is a well-recognized complication in flexible bronchoscopy, especially with advanced procedures. Oxymetazoline is a topical vasoconstrictor often used to reduce or treat bleeding in the nares and airways. A retrospective cohort study was conducted on pediatric patients undergoing flexible bronchoscopy from 2015 to 2025. Language processing was used to analyze bronchoscopy-related procedures, and mixed-effects logistic regression models were used to compare blood pressure, heart rate, and rescue medication use in cohorts that were exposed to nasal, endobronchial, and no oxymetazoline. A total of 2874 patients (41% female, mean age: 5.8 y) underwent 3978 bronchoscopies, 66 (2%) of which were exposed to endobronchial oxymetazoline and 1039 (26%) to nasal oxymetazoline. Endobronchial oxymetazoline was associated with higher systolic blood pressure (β=5.73; 95% CI: 2.48-8.98; P=0.00067), diastolic blood pressure (β=3.68; 95% CI: 1.41-5.96; P=0.0016), and lower heart rate (β=-6.91; 95% CI: -10.84 to -3.00; P=0.00054). These effects were more pronounced when bleeding was reported. Endobronchial oxymetazoline was associated with increased bradycardia (OR: 1.92; 95% CI: 1.09-3.40; P=0.024), but not with increased rescue medication use (OR: 0.69; 95% CI: 0.38-1.24; P=0.21). Endobronchial and nasal oxymetazoline use during pediatric flexible bronchoscopy is associated with a mild increase in blood pressure and a decrease in heart rate, although it is well-tolerated and appears to be safe without an increased need for clinical intervention.
-
8. Diagnostic Value of Multiplane Tool in Virtual Lesion Confirmation in Augmented Fluoroscopy-Guided Navigational Bronchoscopy for Peripheral Pulmonary Lesions.
PMID:日期:2026-08-03The demand for minimally invasive diagnostic techniques for peripheral pulmonary lesions (PPL) is rising. Augmented fluoroscopy (AF) provides real-time guidance by overlaying CT-derived virtual targets onto fluoroscopic images, yet its diagnostic value remains poorly defined. We retrospectively analyzed 226 PPLs targeting procedures performed with navigational bronchoscopy supplemented by AF and R-EBUS between December 2019 and March 2024. TIVL was assessed across 5 standard planes (posteroanterior, 30 degrees toward, 30 degrees away, 30 degrees clockwise, and 30 degrees counterclockwise). Diagnostic yield was defined according to the ATS/ACCP strict criteria. Multivariable logistic regression identified predictors of diagnostic success. Of the 226 analyzed PPLs, 101 (44.7%) showed no R-EBUS signal. In lesions without an R-EBUS signal, diagnostic yield increased from 0% with ≤1 plane to 42% with ≥4 planes. In multivariable analysis, TIVL in 3 planes was associated with a >5-fold higher likelihood of diagnostic success (OR: 5.57; P<0.05), and in ≥4 planes with an almost 14-fold increase (OR: 13.6; P=0.01). Lesions within 16 mm of the point of entry demonstrated stepwise yield improvements up to 89% with ≥4 confirmed planes, while more distant lesions showed no significant benefit. In the ≥3-TIVL-plane subgroup, BMI showed a negative trend toward lower diagnostic yield (OR: 0.92; P=0.059). The number of fluoroscopic planes with confirmed TIVL is a significant determinant of diagnostic yield in AF-guided navigational bronchoscopy, particularly in lesions lacking R-EBUS signals. Multiplane TIVL assessment may enhance diagnostic performance in centers without cone-beam CT or digital tomosynthesis availability.
-
9. Ten Years of Intrabronchial Valve Use for Treatment of Persistent Air Leaks.
9. 支气管内瓣膜治疗持续性漏气十年PMID:日期:2026-08-03Persistent air leaks (PALs), nonhealing fistulas between the bronchoalveolar and pleural space existing for at least 5 to 7 days, are challenging to manage. With the humanitarian use device exemption from the United States Food and Drug Administration beginning in 2008, intrabronchial valves (IBVs) for use in PALs research exist as a burgeoning knowledge base. We completed a single-center retrospective cohort review of IBV placement for PAL from 2015 to 2025. Descriptive statistics were used to analyze demographic and outcomes data. Fine-Gray analysis was used to determine the impact of the duration of PAL before IBV placement on the probability of ever resolving air leaks. A total of 66 cases were reviewed. Patient comorbidities included COPD (43.9%), acute respiratory distress syndrome (28.8%), ILD (16.7%), lung cancer (16.7%), and prior lung transplant (3.0%). Overall, PAL resolution was 63.6% with an average time to air leak resolution after IBV placement of 10.8 days (95% CI: 4.8-16.8; n=42). One-year all-cause mortality was 36.4% (24/66). Each additional 10 days with a chest tube in place before IBV placement corresponded to a 10% lower probability of PAL resolution over time (sHR: 0.901; 95% CI: 0.815-0.996; P=0.042). The cumulative incidence of PAL resolution at 30 days was 39.4% (95% CI: 6.2-72.6) in patients with ILD versus 66.3% (95% CI: 52.6-79.9) in patients without ILD. The use of IBVs for the treatment of PALs remains an effective treatment option. The effectiveness of air leak resolution may be influenced by the timing of IBV placement.
-
10. Diagnostic Yield and Molecular Testing Adequacy of Transbronchial Cryoprobe Biopsy Versus Needle Aspiration in Robotic Bronchoscopy.
PMID:日期:2026-08-03In the AQuIRE trial, most cases (83.6%) did not involve transbronchial needle aspiration (TBNA), often underutilized due to challenges in accessing peripheral pulmonary lesions (PPLs). Advances in robotic bronchoscopy with shape-sensing technology (ssRAB) have mitigated these challenges, but the optimal number of needle and cryoprobe passes for reliable diagnosis remains undefined. This retrospective study compares the diagnostic yield (DY) of TBNA and transbronchial cryoprobe biopsy (TBCB) and their adequacy for molecular testing in PPLs. We performed a retrospective analysis of 166 patients who underwent ssRAB with both TBNA and TBCB from May to August 2024. Fisher exact tests and McNemar χ2 tests were used to compare prevalence differences in DY and molecular testing adequacy between discordant cases. Odds ratios (OR) and 95% CIs of associations between the number of passes and diagnostic yield and rates of obtaining adequate samples for molecular testing were obtained using generalized linear mixed models (GLMMs) with a logit link. TBCB demonstrated a higher diagnostic rate than TBNA (89% vs. 80%, OR=2.04, 95% CI=1.06-4.03; P=0.032), as well as better rates of obtaining samples adequate for molecular testing (60% vs. 20%, OR=5.94, 95% CI=2.31-16.38, P<0.001). TBCB provided diagnostic yields in 55% (χ2=9.33, P=0.002) of cases where TBNA failed to provide a diagnosis and was able to obtain adequate samples for molecular testing in 42% (χ2=15.06, P<0.001) of cases where TBNA was unable to. TBCB suggests a higher diagnostic yield and higher cellular adequacy for molecular testing compared with TBNA, underscoring its potential value as a reliable and versatile diagnostic tool in PPLs.