IEEE Transactions on Biomedical Circuits and SystemsIEEE生物医学电路与系统汇刊
IEEE Transactions on Biomedical Circuits and Systems(英文缩写 IEEE T BIOMED CIRC S),ISSN 1932-4545,eISSN 1940-9990,中文译名:IEEE生物医学电路与系统汇刊 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 5.234 | Q1 |
| 2022 | 5.100 | Q1 |
| 2023 | 3.800 | Q2 |
| 2024 | 4.900 | Q1 |
| 2025 | 5.100 | Q1 |
IEEE Transactions on Biomedical Circuits and Systems 最新收录文献
-
1. A High-Pixel-Density, Wide-DR Subretinal Prosthesis SoC with Power-Aware Light Adaptation and Charge-Recycling Local Dynamic Supply.
1. 一种具有功率感知光适应和电荷回收局部动态供电的高像素密度、宽动态范围视网膜下假体系统级芯片PMID:日期:2026-09-25This paper presents a 400-pixel light-adaptive retinal prosthesis (LARP) system-on-chip (SoC) that aims to support visual perception restoration. The proposed LARP SoC incorporates the power-aware light adaptation (PALA) engine and exposure-controlled light sensor (ECLS) to extend the effective light-sensing dynamic range to 55.48dB within a constrained pixel size. By combining charge-recycling auto-level-sorting multi-supply (CAM) generation with local dynamic supply (LDS) selection, the proposed system optimizes stimulation energy, with simulations showing up to a 45% reduction in stimulation energy consumption compared with conventional fixed-supply stimulation systems. The proposed pixel-clustering architecture integrates compact 80-μm × 80-μm pixels and employs a local return-electrode scheme, with the aim of potentially enhancing visual resolution by confining stimulation currents locally. Ex vivo experiments using wild-type and rd10 mouse retinas demonstrate the functionality of the LARP SoC, showing that it successfully evokes neural responses comparable to those produced by a commercial stimulator.
-
2. FiLMamba: A FiLM-Conditioned Mamba Architecture with an Energy-Efficient FPGA Accelerator for Generalizable Cuffless Blood Pressure Estimation.
2. FiLMamba:一种基于FiLM条件调节的Mamba架构及其节能FPGA加速器,用于可泛化的无袖带血压估计PMID:日期:2026-09-22Cuffless blood pressure (BP) estimation from photoplethysmography (PPG) is limited by a morphology-BP ambiguity that similar waveforms map to different pressures across subjects, causing population-trained models to collapse into mean regression. We propose FiLMamba, a selective state-space model conditioned via Feature-wise Linear Modulation (FiLM) on a 4-D hemodynamic state vector, and Cross-Domain Hemodynamic Alignment (CDHA), which orthogonally decomposes residual cross-corpus shift into unlabeled batch-normalization recalibration and additive bias correction per calibration unit. On MIMIC-BP across 1,524 patients, FiLMamba achieves SBP/DBP standard deviation of error (SDE) of 6.45/4.96mmHg with >2.5× improvement over unconditioned baselines, satisfying Association for the Advancement of Medical Instrumentation (AAMI) compliance. Under training-free transfer, it further reaches 4.29/3.24mmHg on UCI-BP, the first AAMI-compliant training-free cross-dataset result in cuffless BP estimation. A dedicated FPGA accelerator specializes this stack on Zynq UltraScale+ through Heterogeneous Engine Reuse Orchestration (HERO) and Persistent Recurrent In-SRAM Mamba (PRISM), operating at 0.514W dynamic power and 150MHz with 8.23 μJ per sample, 15.3-41.1× below evaluated CPU/GPU platforms, and an energy-delay product of 0.046 J·s that is 1.87-14.8× below every general-purpose baseline.
-
3. {"_":"Digital-Based Potentiostat and Mesoporous Microelectrode Co-Design for Non-Enzymatic Glucose Detection at 0.3V- V and 1.65nW-Power.","sub":["DD"]}
3. 65nW功率下的非酶葡萄糖检测。","sub":["DD"]}PMID:日期:2026-08-31This paper presents a proof-of-concept ultra-low voltage and ultra-low-power chronoamperometric sensing platform for non-enzymatic glucose detection, based on the co-design of a reconfigurable digital-based (DB) potentiostat and a mesoporous platinum (Pt) microelectrode. The DB potentiostat enables current readout and direct digitization from a 0.3V supply at nanowatt-level power, while the microelectrode geometry and mesoporous Pt nanostructuring provide non-enzymatic glucose sensitivity at physiologically relevant concentrations within an electrochemical operating window compatible with the voltage and power constraints of the readout. A frequency-domain signal and noise model of the DB potentiostat is derived for the first time and validated through simulations and measurements, providing a quantitative basis for the electrochemical/readout co-design. Fabricated in 130nm CMOS, the DB potentiostat achieves 5.6 pA input-referred noise, corresponding to a 16.8 pA circuit level minimum detectable current, while consuming 1.65nW at V=0.3V. Electrochemical currents from 600 pA to 650 nA are experimentally measured with R=0.991 linearity under ferrocyanide test conditions. Non-enzymatic glucose measurements with mesoporous Pt microelectrodes at physiologically relevant concentrations, under aerobic conditions and with ascorbic acid as an interferent, demonstrate, to the best of the authors' knowledge, the lowest reported power consumption for CMOS non-enzymatic glucose readout, supporting the potential of the proposed platform for emerging point-of-care diagnostics applications.
-
4. Minimally Invasive Square-based Temporal Interference Stimulation IC for Neuromodulation with Enhanced E-field Delivery.
PMID:日期:2026-08-28Temporal interference stimulation (TIS) has emerged as a promising neuromodulation technique for achieving deep brain stimulation (DBS) with reduced invasiveness. However, conventional transcutaneous TIS suffers from the current shunting effect from the scalp, which limits the electric-field (E-field) delivery to the target region. In addition, conventional sine-based TIS systems rely on noise-sensitive and linearity constrained analog waveform synthesizers. To address these limitations, this work presents a minimally invasive square-based TIS integrated circuit (IC) that simultaneously achieves enhanced E-field delivery and fully digital stimulation waveform generation. The system generates temporal interference (TI) envelopes by digitally controlling an ON/OFF H-bridge driver, significantly simplifying circuit implementation with a gate-driving overhead of only 250 nW per channel. It also delivers higher root-mean square (RMS) energy than sine-based TIS under identical peak-current conditions. The stimulation IC is integrated within a 0.96 mm active area. Experimental tissue phantom measurements show that the proposed system achieves a 2.01 dB higher PSD at Δf and a time-domain envelope amplitude approximately 1.27 times that of sine-based TIS, demonstrating enhanced Δf envelope delivery. The proposed system supports long-term operation (1 s-1 h) and real-time parameter control through an inductive-link interface. It also achieves one of the lowest reported system complexities. These results demonstrate the feasibility of a programmable wireless TIS system for the proposed minimally invasive on-skull configuration.
-
5. An Interference-Aware Adaptive Frequency Channel Selection Transceiver for Low Power Human Body Communication.
5. 一种用于低功耗人体通信的干扰感知自适应频率信道选择收发器PMID:日期:2026-08-14[中文摘要] 用于可穿戴体域传感器网络的传统无线方案受到人体遮挡效应和高功耗的困扰。利用人体导电特性的人体通信(HBC)提供了一种有前景的替代方案,但在10 MHz以下的电准静态(EQS)频段中面临动态信道特性和环境干扰耦合带来的挑战。为减轻干扰影响,现有收发器采用窄带工作方式并采用保守的载波与数据速率比。本文提出了一种工作在10 MHz以下的干扰感知自适应跳频(AFH)HBC收发器,其中AFH以实现干扰驱动的自适应信道选择的方式实现。所提出的AFH开关键控(OOK)收发器集成了一个微小的片上微控制器单元(MCU),能够实现自主跳频控制、实时信道评估和直接传感器接口。该收发器采用65 nm CMOS工艺制造,占用面积0.117 mm²,可实现22-360 kbps的数据速率,在误码率(BER)为10⁻³时具有-33 dB的信号干扰比(SIR)容限,并且在最大体距180 cm时相比单频工作实现了40倍的BER改善。该收发器实现了62.2-79.5 pJ/bit的能效,可为分布式可穿戴应用延长电池寿命,同时受益于10 MHz以下EQS频段固有的安全性。
[英文摘要] Conventional wireless approaches for wearable body sensor networks suffer from body shadowing effects and high power consumption. Human body communication (HBC) utilizing the body's conductive properties offers a promising alternative but faces challenges from dynamic channel characteristics and environmental interference coupling in the sub-10 MHz electro-quasi-static (EQS) regime. To mitigate interference effects, existing transceivers employ narrowband operation with conservative carrier-to-data-rate ratios. This paper presents an interference-aware adaptive frequency hopping (AFH) HBC transceiver operating below 10 MHz, where AFH is realized as interference-driven adaptive channel selection. The proposed AFH on-off keying (OOK) transceiver integrates a tiny on-chip microcontroller unit (MCU) enabling autonomous frequency hopping control, real-time channel assessment, and direct sensor interfacing. Fabricated in 65-nm CMOS occupying 0.117 mm, the transceiver achieves 22-360 kbps data rates, -33 dB signal-to-interference ratio (SIR) tolerance at bit error rate (BER) of 10, and 40× BER improvement over single-frequency operation at maximum body distance of 180 cm. The transceiver achieves 62.2-79.5 pJ/bit energy efficiency, enabling extended battery life for distributed wearable applications, while benefiting from the inherent security of the sub-10 MHz EQS regime.
-
6. A High-Precision Electrical Stimulator ASIC with Adaptive Charge Balancing for Long-Term Implantable Neuromodulation.
PMID:日期:2026-08-06High-performance neuromodulators make essential contributions to the treatment of major neurological disorders and quality of life improvement. To enhance therapeutic efficacy and address safety challenges associated with long-term implanted neuromodulators, several high-performance techniques are proposed in this work. Firstly, a novel redundant current mapping (RCM) technology is developed to improve stimulation resolution at minimal area cost. Secondly, a new power-efficient self-adaptive pulse-width calibration (SAPCA) charge-balancing (CB) scheme ensures long-term stimulation safety. Thirdly, several compliance-extension techniques have been developed to achieve a voltage compliance of±11 V. The ASIC is fabricated in a 180-nm Bipolar-CMOS-DMOS (BCD) process with an area of 0.285 mm/ch. Measurement results show that it achieves 14.5-bit resolution over a 6.5-mA current range and 12.8-bit resolution over a 10-mA current range. The residual voltage (V) is reduced from several V to ±5 mV consuming 1.74 μW. Besides, an in vivo experiment demonstrates that the ASIC can maintain CB under long-term stimulation, thereby preserving chronic neuromodulation safety.
-
7. Motion-Aware Low-Power Wearable Photoplethysmography System with Metamaterial-Enhanced Wireless Telemetry.
7. 运动感知低功耗可穿戴光电容积脉搏波系统及超材料增强无线遥测PMID:日期:2026-08-03In wireless photoplethysmography (PPG) systems, motion artifacts (MAs) and high-power consumption of PPG data acquisition are the critical bottlenecks. MAs induced by body movement during long-term wear significantly degrade PPG signal fidelity, thereby increasing post-processing power consumption. Although previous studies have investigated MA mitigation, power optimization, and wireless connectivity independently, their co-design and system-level integration remains largely unexplored. This paper presents a motion-controlled wearable (MCW) wireless PPG sensing system that features an autonomous motion-gated sampling technique, adaptive power management, and robust data transfer via a metamaterial-enhanced telemetry link. The MCW system autonomously employs motion-gated sampling to acquire heart rate (HR) and blood oxygen saturation (SpO) data under different physical activities. The motion-gated sampling algorithm reduces system power consumption by 55% from its active mode while ensuring robust physiological measurements accuracy. Experimental results demonstrate Mean Absolute Errors (MAEs) ranging from 1.5-6.2 BPM (HR) and 0.5-1.0 % (SpO) across sitting, standing, walking, and running motions, while maintaining PPG signal-to-noise ratio 10 dB under all evaluated activities. Additionally, integrating an electromagnetic bandgap (EBG) structured metamaterial enhances the on-body antenna's performance and decreases the specific absorption rate (SAR) from 4.36 W/kg to 1.677 W/kg. The proposed MCW system, encapsulated in silicone, provides a compact, energy-efficient platform for reliable long-term wearable cardiovascular monitoring.
-
8. AutoFIR: An Automated Framework for Resource-Efficient EEG FIR Filtering on FPGAs.
8. AutoFIR:一种在FPGA上实现资源高效脑电FIR滤波的自动化框架PMID:日期:2026-08-03Real-time electroencephalogram (EEG) processing on wearable platforms faces strict latency, power, and resource constraints, making efficient finite impulse response (FIR) filtering a critical challenge. Many representative field-programmable gate array (FPGA) solutions rely on manual design or vendor-supplied intellectual property (IP) cores, which can limit portability and signal-aware optimization across different signal specifications. This work presents AutoFIR, an automated co-design framework that translates high-level EEG filtering specifications into FPGA-based FIR implementations. AutoFIR integrates signal-aware quantization, shift-add approximation, and systematic architectural optimization to balance signal fidelity, arithmetic complexity, and hardware parallelization. Offline feedback from C-simulations and post-HLS synthesis estimates is used to screen and compare candidate designs within a staged design exploration flow under memory-access and scheduling constraints. On the evaluated Zynq-7020 platform, AutoFIR generates a DSP-slice-free implementation that achieves a 5.22× latency reduction over the unoptimized baseline while maintaining filtering fidelity under the current EEG dataset and filter specification. These results suggest that coordinated, signal-aware automation is promising for the evaluated resource-constrained EEG FIR filtering scenario.
-
9. Ingestible Sensing Capsule with Magnetic-Based Localization Using a Wearable Belt.
9. 使用可穿戴带进行磁性定位的可摄入传感胶囊PMID:日期:2026-07-31Wireless ingestible sensing capsules are of high relevance in the medical field due to their capability to measure biochemical parameters along the gastrointestinal (GI) tract and the potential to associate these with health-related conditions. Obtained sensor information is much more valuable when accompanied by accurate localization, since propagation speed can vary widely. However, most capsule localization systems presented in literature are either not accurate enough or imply bulky external units difficult to wear during daily life activities. Here, a novel ingestible sensing capsule 'GISMO-LOC' for pH and oxidation reduction potential sensing is presented. It features magnetic localization functionality enabled by a wearable transmitter belt. An in-vitro evaluation of the biochemical sensors confirmed the expected biochemical sensing functionality of the capsule. Evaluations of the location estimation in controlled conditions resulted in a mean absolute error (MAE) of 5.7 mm in the volume of interest. A GI trajectory reconstruction using a robot is also presented, with a MAE of 3.8 mm. An on-human evaluation during typical daily life activities resulted in most absolute errors below 2 cm for 'light' activities, 3 cm for 'moderate' activities and 4 cm for high-motion activities such as running. An evaluation of the belt comfort showed volunteer willingness to wear the belt during one week in daytime, while improvement aspects were identified to enable its use during the night. Finally, a limited in-vivo validation of the localization in an animal model was successfully performed. GISMO-LOC is therefore presented as a novel tool for GI tract related research.
-
10. A Bias-Electrode-Free Multichannel ExG Readout IC with Time-Multiplexed PAM-4 Body Channel Communication.
PMID:日期:2026-07-29We propose a multi-channel ExG recording system integrated with body channel communication (BCC), targeting wearable multimodal human-machine interfaces, such as extended reality (XR) and brain-computer interfaces (BCIs). To suppress noise from the BCC transmitter that appears as common-mode interference (CMI) at the ExG analog front end (AFE), we use time-multiplexed acquisition scheme that allocates separate time slots for ExG recording and BCC transmission. This temporal separation preserves ultra-low-noise ExG acquisition, enabling reliable recording of EEG and EOG in addition to EMG and ECG. Because the BCC transmitter must transmit multi-channel ExG data within a limited slot, it requires a high data rate. Using PAM-4 signaling, the proposed system achieves a 10-Mbps data rate. This modulation scheme is enabled by a bias-electrode-free ExG AFE, which increases the BCC signal amplitude by approximately 2.13×, thereby providing sufficient amplitude margin for reliable PAM-4 level discrimination. In addition, a charge-pump-based CMI cancellation loop incorporating a multi-channel least-mean-square (LMS) filter, together with a DC servo loop, mitigates inter-channel mismatch and suppresses differential-mode artifacts. Fabricated in 180-nm CMOS, the chips achieve a total common-mode rejection ratio (CMRR) of 101.1 dB and suppress electrode DC offsets up to 500 mV, while maintaining stable operation under 18-Vpp common-mode interference and 15% electrode mismatch.