Journal of the Mechanical Behavior of Biomedical Materials生物医学材料力学行为杂志
Journal of the Mechanical Behavior of Biomedical Materials(英文缩写 J MECH BEHAV BIOMED),ISSN 1751-6161,eISSN 1878-0180,中文译名:生物医学材料力学行为杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 4.042 | Q2 |
| 2022 | 3.900 | Q2 |
| 2023 | 3.300 | Q2 |
| 2024 | 3.500 | Q2 |
| 2025 | 4.100 | Q2 |
Journal of the Mechanical Behavior of Biomedical Materials 最新收录文献
-
1. Characterization of time-dependent and history-dependent mechanical behaviour of human masseter muscle.
1. 人体咬肌的时间依赖性和历史依赖性力学行为表征PMID:日期:2026-10-01The human masseter muscle is one of the primary muscles responsible for mastication and mandibular movement; however, its intrinsic mechanical properties remain insufficiently characterized. In this experimental study, the nonlinear, viscoelastic, and history-dependent behaviour of the human masseter muscle was investigated using ex vivo uniaxial cyclic tensile tests. Masseter muscle samples prepared from fresh and formalin-preserved cadavers were tested under two loading protocols: a stepwise stress-relaxation protocol with progressively increasing stretch levels and a constant stretch protocol with repeated loading to a fixed maximum stretch, at two strain rates. The influence of strain rate and formalin preservation on the mechanical behaviour of the tissue was investigated. The results showed that formalin-preserved samples showed higher stiffness than fresh samples. Under cyclic loading, energy dissipation, stress-softening, residual deformation, and cyclic conditioning progressively changed during the initial loading cycles and reached stabilization during the final cycle. These findings provide experimental evidence that the human masseter muscle exhibits nonlinear, viscoelastic, and history-dependent mechanical behaviour under cyclic tensile loading. The proposed model provides baseline experimental data that may support future biomechanical modelling and related clinical investigations.
-
2. Blood clot contraction depends on spatial distribution of fibrin, red blood cells and platelets.
PMID:日期:2026-09-30Whole-blood clot contraction is a mechanically active process in which fibrin, platelets, red blood cells (RBCs), and fluid reorganize to determine the final compacted state of a clot. Although clot contraction is often associated with platelet activity, experiments and simulations show that RBCs and fibrin can redistribute during contraction, depending on clot size, shape and other parameters. Here, we propose a physics-based three-dimensional equilibrium continuum model for whole-blood clot contraction that combines nonlinear fibrin-network elasticity, explicit RBC-RBC and RBC-fibrin interaction energetics, osmotic effects, and platelet-generated active stress. The model is calibrated using homogeneous contraction measurements and is applied to homogeneous and heterogeneous clots in spherical, cylindrical, cubic, and flat geometries. For homogeneous clots, the model predicts that the equilibrium volume ratio is independent of clot size within the present scale-free equilibrium formulation. For heterogeneous clots, scaling the clot size while preserving the same prescribed dimensionless spatial distribution of fibrin, RBCs, and platelet activity leaves the normalized stress and strain fields, as well as the final volume ratio, unchanged. Thus, clot size alone does not determine equilibrium shrinkage in this continuum model. In contrast, when the clot size and whole-clot composition are fixed, changing the spatial distribution of RBC-rich and RBC-poor regions produces substantial changes in contraction, with the equilibrium volume ratio spanning an absolute range of approximately 0.21 in VV over the parameter set examined. Parameter sweeps further reveal an intermediate core-shell interface position that minimizes the equilibrium volume ratio and therefore maximizes contraction, reflecting a competition between an increasingly concentrated and mechanically resistant RBC-rich core and a deformable outer shell. These results provide a continuum mechanics framework for separating the effects of clot size, spatial heterogeneity, and whole-blood composition on clot contraction.
-
3. Rate dependent mechanical response of avian skeletal muscle under quasi-static and dynamic uniaxial tension.
3. 禽类骨骼肌在准静态和动态单轴拉伸下的率相关力学响应PMID:日期:2026-09-26Aircraft bird strikes pose a substantial threat to aircraft and passenger safety. In the event of bird-aircraft collisions, the forces exerted on aircraft components can cause extreme damage, severely impacting system performance or even causing catastrophic failure. The magnitude and severity of the forces exerted by birds on aircraft components during these violent events can vary drastically dependent on the initial conditions of impact. To better simulate these impact forces, robust quantitative data characterizing the rate and orientation dependent material behaviors of anatomical components such as skeletal muscle is desired. This data can only be gathered through thorough experimentation of biological components under a wide range of external stimuli. Despite the stress-stretch response of skeletal muscles being well documented to behave anisotropically, fewer studies have documented skeletal muscles' high levels of strain rate dependency. In avian skeletal muscle tissue, studies characterizing the muscles' strain rate dependent and anisotropic material behavior under dynamic tension have yet to be made publicly available. In this descriptive study, tension experiments were conducted across a broad range of strain rates via a hydraulic load frame (10-10 s) and a modified Split-Hopkinson bar (1300-2000 s). This range of loading rates allowed quantification and comparison of rate dependency of skeletal muscles extended in-line with fiber direction and muscle extended transverse to fiber direction. Results from this study highlighted that the observed mechanical response of avian skeletal muscle tissue under tension is highly dependent on both strain rate and direction of extension in relation to muscle fibers. Furthermore, it was observed that strain rate dependency was impacted by both the direction of load and whether or not the muscle tissue had been extended beyond the initial nonlinear (toe) region. The results discussed in this work have broad implications in the interpretation of the anisotropic stress-stretch behavior of skeletal muscle as a whole, particularly when reviewing quasistatic-only studies.
-
4. Cryopreservation-induced changes in the mechanical properties of human saphenous vein grafts.
4. 冷冻保存引起的人大隐静脉移植物力学特性的变化PMID:日期:2026-09-26This study investigates the effects of cryopreservation and thawing rate on the mechanical properties of human saphenous vein grafts (SVGs) used in vascular bypass procedures. Native, non-cryopreserved veins were compared with cryopreserved grafts thawed either slowly at 2-8 °C or quickly in a 37 °C water bath. Cryopreserved grafts were treated with dimethyl sulfoxide and hydroxyethyl starch, frozen using a controlled-rate protocol, and subsequently stored below -160 °C in liquid-nitrogen vapor. Inflation experiments were performed on 36 human SVG specimens (12 per group) to characterize the pressure-strain and stress-strain behavior under physiologically relevant loading conditions. All grafts exhibited the nonlinear and anisotropic mechanical response typical of vascular tissue. Cryopreservation caused a substantial reduction in wall thickness, approximately 50% compared to native veins, resulting in markedly higher stresses during pressurization. While circumferential mechanical behavior remained similar across all groups, significant changes were observed in the axial direction. Native veins showed a stiffer axial response and some samples shortened during pressurization, whereas cryopreserved grafts were axially more compliant and predominantly elongated under load. These findings suggest that cryopreservation alters the native anisotropic mechanical response of the venous wall. No statistically significant differences were identified between slowly and quickly thawed grafts in the majority of measured quantities. However, quickly thawed samples demonstrated greater variability in mechanical response, indicating lower reproducibility. The results suggest that cryopreservation has a much stronger influence on graft biomechanics than thawing rate itself. Clinically, the observed axial elongation of cryopreserved grafts indicates that graft prestretching during implantation may be beneficial to prevent undesirable deformation after exposure to arterial pressure.
-
5. Maxillary oral mucosa exhibits region-specific but No direction-dependent mechanical tensile properties.
5. 上颌口腔黏膜表现出区域特异性,但无方向依赖性的机械拉伸性能PMID:日期:2026-09-23This study investigated the regional and direction-specific tensile properties of native human oral mucosal tissues. Tissue specimens were harvested from three distinct maxillary regions, namely the hard palate, attached gingiva, and alveolar mucosa from 11 partially dentate donors, totaling 34 specimens. Using the osmotic stress protocol to standardize water content, specimens underwent uniaxial tensile testing. Mechanical parameters, including elastic modulus, Cauchy stress and stretch at failure, were calculated and statistically analyzed. The attached gingiva yielded a higher elastic modulus than the alveolar mucosa and a greater Cauchy stress at failure than both the alveolar mucosa and the hard palate, while stretch at failure was similar across all regions examined. No statistically significant direction-dependent differences were detected within the investigated regions. The attached gingiva demonstrated greater variability in elastic modulus and stress values. Collagen fiber coherency and rupture patterns differed between anatomical regions; however, collagen coherency showed no significant overall correlation with elastic modulus or Cauchy stress at failure. Furthermore, failure patterns appear to be site-specific. The present study constitutes the first comprehensive morpho-mechanical characterization of human maxillary mucosa, thereby providing novel insight into region-specific mechanical resilience. These findings hold significant relevance for the optimization of prosthetic design, the advancement of oral biomechanical understanding, and the refinement of computational models in both clinical and bioengineering contexts.
-
6. Gradient orientation governs mechanical and regenerative outcomes in functionally graded bone scaffolds: a coupled finite element-agent-based modelling study.
6. 梯度取向决定功能梯度骨支架的力学与再生结果:一项有限元-智能体耦合建模研究PMID:日期:2026-09-23Critical-sized bone defects remain a major clinical challenge, requiring scaffolds that combine mechanical stability with regenerative capacity. Functionally graded scaffolds offer a promising strategy by spatially varying porosity to optimise load transfer and tissue ingrowth. Here, we apply an established coupled poroelastic finite element-agent-based modelling (FEA-ABM) framework as a comparative platform to evaluate six cylindrical scaffold configurations modelled using Ti-6Al-4V material properties: two opposing axial-gradient designs, two opposing radial-gradient designs, and their corresponding uniform controls under physiologically representative loading. Poroelastic finite element analysis was used to compute local shear strain and fluid velocity, which regulated progenitor differentiation, proliferation, apoptosis, and migration in the agent-based model. Simulations representing 150 days of healing showed that axial gradients with larger pores at the host bone interface produced the greatest bone ingrowth, reaching approximately 77% pore occupancy compared with 69% in the uniform axial scaffold and 60% in the opposite axial gradient. In contrast, radial gradients did not substantially alter overall bone regeneration compared with the uniform radial scaffold, but the design with denser peripheral struts markedly improved mechanical performance, reducing volume-weighted P99 von Mises stress to approximately 41 MPa compared with about 57-71 MPa in the radial uniform and opposite radial-gradient designs. These findings reveal a design trade-off between regenerative capacity and structural competence, suggesting that gradient orientation should be selected according to the mechanical and biological requirements of the target defect environment. By applying the FEA-ABM framework consistently across the investigated configurations, this study provides comparative evidence to inform the selection of pore-size-gradient designs according to the regenerative and mechanical requirements of the target defect.
-
7. Corrigendum to "The influence of patellar fat pad resection on knee joint friction and damping: An in vitro study in New Zealand white rabbits" [J. Mech. Behav. Biomed. Mater. 174, (2026), 107257].
7. 对“髌下脂肪垫切除对膝关节摩擦与阻尼的影响:一项新西兰白兔体外研究”的勘误 [J. Mech. Behav. Biomed. Mater. 174, (2026), 107257]PMID:日期:2026-09-22该文献暂无摘要。
-
8. Comparison of the mechanical response of muscle and adipose tissue under indentation loading between younger and older individuals in the context of pressure ulcer prevention.
8. 在压疮预防背景下年轻人和老年人肌肉与脂肪组织在压痕载荷下力学响应的比较PMID:日期:2026-09-19This study investigates age-related differences in the mechanical response of muscle and adipose tissue under indentation loading to identify potential biomechanical markers for pressure ulcer (PU) risk. The assumption underlying this work is that variations in tissue stiffness may correlate with PU susceptibility, especially in older individuals. Our working hypothesis posits that older, at-risk individuals will exhibit altered tissue properties, reflected in the force-displacement and strain responses to mechanical loading. Twenty-four participants were divided into three groups: younger asymptomatic, older asymptomatic, and older hospitalized individuals. Using a custom force sensor-ultrasound setup, force-displacement and force-strain responses from the anterior thigh were collected, and Ogden hyper-elastic constitutive parameters were derived through inverse optimization. This bedside-measured dataset allowed for the assessment of tissue behavior relevant to PU prevention, with a focus on clinical applicability. Results indicate age-associated stiffening in muscle tissue, with older participants displaying quicker stiffening and reduced initial stiffness compared to younger participants. Adipose tissue measurements, however, were more sensitive to noise, limiting their reliability. Despite observed differences, statistical significance was not achieved, likely due to the limited sample size and the predefined grouping of participants based on recruitment criteria. Future work will increase sample size, conduct retrospective participant analysis, and explore alternative constitutive laws to better understand tissue behavior and its relation to pressure ulcer risk.
-
9. Inter-laboratories comparison of different numerical models to four experimental datasets of human vertebrae with or without metastases.
9. 对不同数值模型在有无转移的人体椎骨四组实验数据集上的实验室间比较PMID:日期:2026-09-18Bone metastases, remarkably common in the vertebral bodies of advanced cancer patients, are associated with an increased risk of vertebral fracture. To assess vertebral strength, subject-specific biomechanical models have been proposed based on quantitative computed tomography. Such models have been evaluated on a single dedicated dataset often acquired by the same team. The goal of this paper is to compare different biomechanical models with four experimental datasets to strengthen their validation. Finite element models developed by three groups at the University of Bern, University of Lyon, and "Institut de Biomécanique Humaine Georges Charpak" of Paris, were used to simulate the strength of four different experiments that included 1) intact non-metastatic vertebrae with endplates embedded in endcaps during experimental tests, vertebrae with simulated defects representing osteolytic bone metastasis foci with endplates removed, and metastatic vertebrae from cancer donors with the endplates removed. The simulation results show the determination coefficient to range between 0.28 and 0.96 with a slope of the correlation between experimental and numerical failure strengths from 0.32 to 1.69. The bias (difference between experimental and numerical failure strengths) varied from -3749 and + 1368 N, corresponding to -48.6% to +77%. The experimental removal of the endplates influenced FE model predictions. This study illustrates the need for extensive validation of models before their potential use in clinical practice. To encourage such validation, the experimental datasets were made available in open data.
-
10. Effects of build orientation and manufacturing system characteristics in digital light processing additive manufacturing on the properties of zirconia.
10. 数字光处理增材制造中构建方向和制造系统特性对氧化锆性能的影响PMID:日期:2026-09-16To evaluate the influence of build orientation and manufacturing system characteristics in digital light processing (DLP) additive manufacturing on the surface roughness, internal structure, and biaxial flexural strength of 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP). Disc-shaped specimens (15 × 1 mm) were fabricated using subtractive manufacturing (SM) and two DLP-based systems with different system characteristics. Additively manufactured specimens were produced at 0°, 45°, and 90° orientations. Surface roughness (Ra) was measured using confocal laser scanning microscopy, internal structure was evaluated using microcomputed tomography (micro-CT), and biaxial flexural strength was determined using the piston-on-three-ball method in accordance with ISO 6872:2015. The 0° groups (LAM0 and AM0) and the SM control exhibited low surface roughness and high flexural strength (∼900-1100 MPa), with no significant differences. The 45° groups (LAM45 and AM45) and the LAM90 group exhibited increased roughness and orientation-dependent surface features, along with reduced strength (∼450-520 MPa). Notably, AM90 was an exception to this orientation-dependent pattern: despite its 90° build angle, AM90 retained high strength (922.1 ± 77.1 MPa) and a high Weibull modulus (m = 13.87), comparable to the 0° and SM groups, whereas LAM90 exhibited both reduced strength (455.7 ± 185.6 MPa) and low reliability (m = 3.20). Micro-CT revealed layer-related structural features associated with build orientation. This divergence between AM90 and LAM90 indicates that, at the 90° orientation, manufacturing system-level characteristics can outweigh the expected orientation-dependent reduction in mechanical performance. Build orientation significantly influences the surface characteristics, internal structure, and mechanical performance of DLP-fabricated zirconia. Differences between manufacturing systems may also affect outcomes, particularly under vertical (90°) build conditions; however, because the two DLP systems compared here differed simultaneously in platform size, projection resolution, and pixel pitch, these effects cannot be attributed to a single parameter and should be interpreted as reflecting combined, system-level characteristics. These findings suggest manufacturing-process considerations for build orientation selection in DLP-based zirconia fabrication, and indicate that system-specific characteristics may also warrant consideration. As this study used simplified disc specimens, direct clinical extrapolation should be made with caution pending validation in clinically relevant geometries.