Applied Radiation and Isotopes应用辐射与同位素
Applied Radiation and Isotopes(英文缩写 APPL RADIAT ISOTOPES),ISSN 0969-8043,eISSN 1872-9800,中文译名:应用辐射与同位素 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 1.787 | Q2 |
| 2022 | 1.600 | Q2 |
| 2023 | 1.600 | Q2 |
| 2024 | 1.800 | Q2 |
| 2025 | 2.100 | Q2 |
Applied Radiation and Isotopes 最新收录文献
-
1. Evaluation of optimization in digital mammography through different formulations of Figure of Merit.
1. 通过不同品质因数公式对数字乳腺摄影优化的评估PMID:期刊:日期:2026-10-01Mammography is a fundamental imaging modality for the early detection of breast cancer. The usage of Figure of Merit (FOM) to assess optimization in digital mammography helps to ensure a balance between image quality and the radiation dose in the procedures. The aim of this work was to find and discuss the best trade-off between dose and image quality in a digital mammography system through different Figure of Merit formulations, using CDMAM Phantom and ACR Phantom. Contrast-detail analyses were carried out with Inverse Image Quality Figure index (IQF), for three simulated thickness with PMMA plates (2.5, 3.5 and 4.5 cm), and contrast-to-noise ratio (CNR) for 4.5 cm thick ACR Phantom. The images were taken using the semi-automatic mode (AEC) and fully-automatic mode (OPDOSE) with four peak voltage values (26, 27, 28, and 29 kVp) and target-filter combinations of Mo/Mo, Mo/Rh, and W/Rh. The different FOM formulations took into account IQF and CNR as image quality parameters. The Mean Glandular Dose (MGD) was used as the dosimetric parameter in all cases. For all thicknesses, the parameters optimized by FOM, especially those with target-filter W/Rh, showed an improvement in image quality and a reduction in MGD compared to the results obtained with the OPDOSE mode. Furthermore, for the 4.5 cm thickness, the same trend was observed in the definition of the optimized parameters using different image quality metrics. The IQF proved to be a more detailed and objective parameter for intra-system evaluation in mammography, enabling similar results to the CNR.
-
2. {"_":"Tc radiolabeled papain nanoparticle: In silico dosimetry evaluation using Monte Carlo codes and the DM_BRA voxel phantom and OLINDA/EXM for internal dosimetry based on experimental biodistribution data.","sup":["99m"]}
PMID:期刊:日期:2026-10-01Green nanotechnology has gained prominence in developing biocompatible materials for therapeutic and diagnostic applications in oncology and nuclear medicine. An innovative system was presented, based on papain nanoparticles (P-NPs) synthesized by gamma irradiation and radiolabeled with technetium-99m (Tc) for molecular imaging using SPECT. Papain, a protease extracted from Carica papaya, exhibits anticancer, antibacterial, and antioxidant properties, making it an excellent nanocarrier for radionuclides. Herein, an in silico dosimetry calculation was performed using the Monte Carlo (MC) codes MCNP6.2 and EGSnrc. The aim was to estimate and compare the absorbed dose per injected activity (mGy/MBq) between these codes in the organs and tissues of the DM_BRA mouse voxelized phantom, using the in vivo biodistribution data for Tc-P-NPs. The OLINDA/EXM internal dosimetry software was also used in this study, as it has animal models. Results indicate that Tc-P-NPs exhibit high tumor affinity, with a favorable distribution profile for breast cancer imaging. The results showed doses between the MC codes with percentage differences less than 11%, 6%, and 16% for the Healthy Balb/c Mice, 4T1 Tumor-Bearing Mice, and Spontaneous Breast Cancer Mice (MMTV-PyMT), respectively. For the doses obtained in OLINDA/EXM, the smallest percentage difference was 0.3% for MCNP6.2 and 0.2% for EGSnrc, considering all groups. The similarity between experimental data and Monte Carlo calculations highlights the reliability of the simulation method for estimating radiation biodistribution in healthy mice. This comparison underscores the importance of validating computational models with experimental data to ensure accurate predictions of organ-specific dose distributions.
-
3. Determination of potassium, sodium, and manganese in textured soy protein by instrumental neutron activation analysis and gamma-ray spectrometry.
PMID:期刊:日期:2026-09-29Glycine max, commonly known as soybean, is one of the most widely cultivated legumes in Brazil and represents a nutritionally relevant source of proteins, lipids, dietary fibers, and essential minerals. In the form of textured soy protein, it constitutes a low-cost alternative to animal-derived proteins, with potential to support food security strategies, reduce social vulnerability, and inform public policies aimed at improving access to nutritious foods. This study aimed to identify and quantify potassium, sodium, and manganese in a commercial textured soy protein product purchased from a local market in Rio de Janeiro, Brazil. The analytical approach combined Instrumental Neutron Activation Analysis (INAA), using the comparative method, with Gamma-Ray Spectrometry (GRS). Irradiations were performed in the Argonauta reactor at the Instituto de Engenharia Nuclear, operating at 34 W and a thermal neutron flux of 10 n·cm·s for 30 min. After irradiation, induced radionuclides were measured by GRS using a high-purity germanium detector with 25% relative efficiency and 1.8 keV resolution at the 1332 keV photopeak of Co, together with the DSPEC jr 2.0 system and Maestro v7.0 software. Element identification was based on gamma energies and half-life confirmation, while quantification used the INAA method. Concentrations were 1576.05 ± 25.54 mg/100 g for potassium, 4.55 ± 0.76 mg/100 g for sodium, and 2.30 ± 0.18 mg/100 g for manganese. The results demonstrate the applicability of INAA and GRS for multielemental analysis in food matrices and indicate a favorable nutritional profile for the analyzed textured soy protein product, particularly its high potassium and low sodium content.
-
4. {"_":"Thick-target yield of Cu(α,n)Ga near threshold and implications for nuclear medicine, deep underground detector backgrounds, and nucleosynthesis.","sup":["65","68"]}
PMID:期刊:日期:2026-09-29We report thick target yields of Cu(α,n)Ga from α energies E=6.5-8 MeV measured via neutron-counting at the Edwards Accelerator Laboratory at Ohio University. Our results agree with prior results based on single-foil irradiations, while disagreeing with thick-target yields inferred from stacked-foil irradiations by up to an order of magnitude. Based on comparisons of our and prior measurements to Hauser-Feshbach calculations, we estimate the thick-target yield for Ga from E=14MeV impinging on 100%-enriched copper (Cu) is 161 MBq/μAh (for He), which is in agreement with the current IAEA estimate of 156 MBq/μAh. At E=8 MeV, where radioimpurity-free production of Ga could be realized with a natural copper target, our yield estimate is nearly 4× lower than the IAEA estimate. We find that the Cu(α,n) cross section estimates presently employed for neutrino and dark matter detector backgrounds and the Cu(α,n) astrophysical reaction rate recently recommended for nucleosynthesis calculations are in agreement with our measurement results.
-
5. {"_":"Tracing the groundwater influx into the Yamuna River using radon (Rn).","sup":["222"]}
5. 利用氡(Rn)示踪地下水对亚穆纳河的补给PMID:期刊:日期:2026-09-26Understanding the surface water-groundwater exchange is essential for the sustainable water resource management, contaminant transport assessment, and overall health of the river ecosystem. Radon (Rn) is a widely used natural tracer for identifying the groundwater discharge to rivers because of its conservative behavior, short half-life (3.82 days) and activity concentration relatively much higher in groundwater than surface water. Despite the hydrological importance of the Yamuna River, the groundwater exchange along its middle and lower reaches remains poorly understood. This study presents the first systematic Rn based assessment of groundwater influx into the Yamuna River along a ∼250 km reach from Panipat (upstream) to Agra (downstream). Radon activity was measured at 9 locations within the river and nearby groundwater wells, while Electrical Conductivity (EC) was recorded as a complementary hydrochemical tracer. Groundwater influent zones were identified based on the elevated riverine Rn activity. Rn activity concentration of the river ranged from 0.069 to 6.295 Bq/L (mean: 1.010 Bq/L), while, the groundwater showed consistently higher values (mean: 4.268 Bq/L). Two groundwater influx zones were identified. The primary zone occurred at Mohana, Mathura where river Rn reached 6.295 Bq/L and adjacent groundwater wells recorded 7.207-7.549 Bq/L. A secondary influx zone was detected at Wazirabad, Delhi, with river Rn of 1.387 Bq/L. The remaining river sampling stations exhibited near background activities, indicating limited groundwater contribution. The results demonstrate that the groundwater discharge to the Yamuna River is spatially discrete rather than diffuse, and they are concentrated at two locations associated with the presence of geological structure such as faults and lineaments. The identification of these preferential groundwater influx zones has direct implications for contaminant load estimation, sustainable groundwater abstraction policy, and river flow modelling in the Yamuna basin.
-
6. {"_":"Theoretical assessment and optimization of cyclotron production routes for high-purity In for PET applications.","sup":["110m"]}
PMID:期刊:日期:2026-09-25The positron-emitting radionuclide indium-110 (In; T = 69.1 min, J = 2, E = 0.0621 MeV) is an attractive candidate for the positron emission tomography (PET). In the present work, the cyclotron production routes of In through proton induced reactions on cadmium isotopes (i.e.Cd, Cd, Cd, Cd) along with the Ag(α,n) process are investigated for the direct production of In and In. The measured excitation functions are compared with the prediction by the nuclear model codes, TALYS, EMPIRE and ALICE-IPPE. The isomeric cross sections ratios are envisaged to compare the isomeric and ground states over the discussed energy range. The integral yields are deduced for In, In and In. The optimum energy ranges, to produce the desired In, are presented along with the co-production In and In levels. The results demonstrate that the Cd(p,n) reaction provides the most favorable compromise between yield and purity for the cyclotron production of In. The evaluated excitation functions and recommended energy ranges provide useful guidance for the practical production of In for PET applications. The study identifies optimum projectile energy windows for maximizing the production of In while minimizing radionuclidic impurities.
-
7. A hybrid biokinetic-Monte Carlo framework for internal dosimetry of I-131 using a modified MIRD phantom.
PMID:期刊:日期:2026-09-25Iodine-131 is widely used in nuclear medicine, and accurate assessment of its internal dosimetry requires appropriate biokinetic and radiation transport models. Integrating physiological iodine kinetics with Monte Carlo simulation provides a methodological framework for estimating organ doses. Nevertheless, during systemic distribution, several non-target organs such as the salivary glands, stomach, and urinary bladder are exposed to ionizing radiation, leading to potential side effects including sialadenitis and xerostomia. A hybrid dosimetric framework was developed by integrating a physiological biokinetic model of iodine metabolism with Monte Carlo photon and beta transport simulation. The Leggett iodine model was implemented in MATLAB to compute organ-specific time-activity curves and cumulated activities. Since the Leggett model is based on normal thyroid function, the comparison with ICRP data was performed for validation of the calculation method and not for direct application to thyroidectomized differentiated thyroid cancer patients. The classical MIRD phantom was modified by incorporating salivary glands as additional anatomical structures to enable comparative assessment of absorbed dose in non-target tissues. The modified phantom was simulated by MCNP code to estimate organ absorbed doses following oral administration of I-131. The calculated results showed acceptable agreement with ICRP Publication 128 reference data, with a median deviation of 3.7% and a worst case deviation of 40% for the heart wall, attributable to known geometric limitations of the stylized cardiac model. The total absorbed dose to the salivary glands was found to be 0.23 mGy MBq, highlighting their significant exposure during therapeutic procedures.
-
8. {"_":"PVA/PEG-based BC/BiO nanocomposite films: Physicochemical characterization and computational gamma- and neutron-shielding assessment.","sub":["4","2","3"]}
8. {"_":"PVA/PEG基BC/BiO纳米复合膜:物理化学表征与伽马和中子屏蔽计算评估。","sub":["4","2","3"]}PMID:期刊:日期:2026-09-24PVA/PEG (80:20) blend films containing BC, BiO, and hybrid BC/BiO fillers were prepared by solution casting and characterized to establish relationships among their structural, thermal, optical, electrical, morphological, and radiation-interaction properties. XRD analysis showed that filler incorporation reduced the crystallinity of the PVA/PEG matrix from 82.38% to 72.15%, 69.73%, and 57.26% for the BiO-, BC-, and hybrid-filled films, respectively. The 20 wt% BC formulation exhibited the highest thermal stability T = 380 °C and the most spatially uniform electrical response, whereas the hybrid composition exhibited the lowest optical band gap (3.32 eV) and greatest structural disorder. Gamma-ray attenuation was evaluated computationally using GAMOS 7.0 and Phy-X/PSD over 0.0595-1.50 MeV. The BiO-containing composition exhibited the strongest calculated low-energy photon attenuation; at 0.0595 MeV, GAMOS yielded an LAC of 1.613 cm, corresponding to an HVL of 0.430 cm. GAMOS and Phy-X results differed by approximately 0.7-5.1% at representative energies, providing a computational cross-check. Thermal-neutron calculations using the NIST/NCNR approach showed that the BC-containing composition had the highest macroscopic absorption cross section (9.158 cm), the lowest transmission (42.28% at 0.060 cm), and the smallest 1/e penetration depth (0.070 cm), whereas differences in the calculated fast-neutron removal cross section were modest. These results indicate complementary roles of BiO in low-energy photon attenuation and BC in thermal-neutron absorption. The shielding results are computational and require experimental validation before practical implementation.
-
9. {"_":"Assessing the effectiveness of F-Fluorocholine PET-CT as the leading imaging technique compared to Tc-Sestamibi scans and ultrasonography for diagnosing hyperparathyroidism.","sup":["18","99m"]}
PMID:期刊:日期:2026-09-23Accurate preoperative localization of hyperfunctioning parathyroid tissue is paramount for the success of minimally invasive parathyroidectomy in primary hyperparathyroidism (PHPT). Conventional imaging with Tc-sestamibi (MIBI) scintigraphy and cervical ultrasonography (US) has significant limitations in sensitivity and specificity. This study aims to evaluate the diagnostic performance of F-fluorocholine PET/CT (FCH-PET/CT) as a preferred imaging modality compared with conventional methods. ology: A prospective, non-interventional cohort study was conducted on 82 patients with biochemically proven PHPT who underwent preoperative localization with US, MIBI-SPECT/CT, and FCH-PET/CT between January 2022 and January 2025. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and detection rates of each modality were calculated, with histopathology and clinical follow-up serving as the reference standard. FCH-PET/CT demonstrated significantly higher sensitivity (84.1% vs. 36.6%) and detection rate (85.4% vs. 30.5%) compared to MIBI. Ultrasonography showed lower performance metrics than FCH and higher than MIBI except NPV% for the latter. In 41 cases (50%) where MIBI was negative or equivocal, FCH-PET/CT correctly localized hyperfunctioning tissue in 36 cases (87.8%), including cases of multi-glandular disease, ectopic adenomas, and post-surgical recurrence. The specificity and PPV for FCH-PET/CT were also superior, confirming its reliability in identifying true positives. F-fluorocholine PET/CT is a significantly more effective imaging technique for preoperative parathyroid localization than conventional MIBI scintigraphy and ultrasonography. Its implementation, particularly in cases with negative, equivocal, or discordant conventional imaging, can drastically improve surgical planning, minimize operative failure and reoperation rates, and enhance patient outcomes in PHPT.
-
10. Ultra-high-fidelity reactor pressure vessel monitoring using SERF magnetometer arrays.
10. 使用SERF磁力仪阵列的超高保真反应堆压力容器监测PMID:期刊:日期:2026-09-22Continuous surveillance of Reactor Pressure Vessels (RPVs) in Pressurized Water Reactors (PWRs) is critical for Long-Term Operation (LTO), yet conventional inspection techniques typically require reactor shutdowns or direct access to high-radiation environments. This study proposes a physics-based Digital Twin framework for remote, non-intrusive monitoring of RPVs using Spin-Exchange Relaxation-Free (SERF) magnetometers. The Digital Twin is formulated as a physics-informed computational surrogate coupling first-principles neutron transport with magnetostatic field modeling and validated constitutive material laws to infer irradiation-induced embrittlement without breaching the pressure boundary. Because full-scale experimentation in operating PWRs is constrained by radiological conditions, the framework is validated using benchmark methodologies employed in safety-critical nuclear analysis, including comparison with International Atomic Energy Agency (IAEA) Coordinated Research Project reference data and reported post-irradiation magnetic measurements. Simulations indicate that an eight-sensor gradiometric SERF array placed on the biological shield wall at approximately 2.5m provides adequate shielding for alkali-vapor cell operation while maintaining sensitivity to permeability perturbations within the RPV wall. The configuration achieves a detection margin of 3.3×10 relative to background magnetic noise, with constitutive validation yielding a Mean Absolute Error of 2.7%.