Cardiovascular Intervention and Therapeutics心血管介入与治疗
Cardiovascular Intervention and Therapeutics(英文缩写 CARDIOVASC INTERV TH),ISSN 1868-4300,eISSN 1868-4297,中文译名:心血管介入与治疗 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 未收录 | N/A |
| 2022 | 3.200 | N/A |
| 2023 | 3.100 | Q2 |
| 2024 | 5.800 | Q1 |
| 2025 | 5.500 | Q1 |
Cardiovascular Intervention and Therapeutics 最新收录文献
-
2. Intravascular imaging in myocardial infarction and ischemia with nonobstructive coronary arteries.
2. 心肌梗死及非阻塞性冠状动脉缺血中的血管内成像PMID:日期:2026-09-25Myocardial infarction with nonobstructive coronary arteries (MINOCA) and angina or ischemia with nonobstructive coronary arteries (ANOCA/INOCA) are heterogeneous syndromes that cannot be adequately characterized by coronary angiography alone. Optical coherence tomography (OCT) identifies thrombus, plaque disruption, and other superficial coronary abnormalities, whereas intravascular ultrasound (IVUS) better characterizes plaque burden, positive remodeling, intramural hematoma, and myocardial bridging. Their roles differ between acute and chronic presentations. In MINOCA, targeted intracoronary imaging during the index angiogram helps identify an acute epicardial mechanism, whereas early cardiac magnetic resonance characterizes myocardial injury, localizes the affected territory, and excludes nonischemic mimics. In ANOCA/INOCA, coronary function testing remains central to identifying vasospastic and microvascular endotypes. Structural findings such as layered plaque, intraplaque hemorrhage, fibroatheroma, or myocardial bridging vary in their mechanistic significance and should not be assumed to represent the cause of the index event solely on the basis of morphology. Territorial myocardial concordance strengthens their association with the involved coronary territory but does not by itself establish causality. We review the complementary roles of OCT and IVUS, examine differences in diagnostic yield among contemporary MINOCA studies, and propose a framework for interpreting intracoronary imaging findings in MINOCA in the context of myocardial and functional information. This approach aims to improve consistency in the interpretation and reporting of intracoronary imaging findings.
-
3. TAVI-TEC: an AI-based tool for procedural planning of transcatheter aortic valve implantation.
3. TAVI-TEC:一种基于人工智能的经导管主动脉瓣植入术手术规划工具PMID:日期:2026-09-24Computed tomography angiography (CTA) is crucial for preprocedural TAVI planning, providing the anatomical information required for prosthesis sizing and vascular access assessment. As the volume of TAVI procedure increases, improving efficiency and standardizing annotations is becoming essential in clinical practice. This study presents TAVI-TEC, a fully automated artificial intelligence-based framework integrated into a web-based DICOM viewer for routine preoperative TAVI planning. Pre-procedural CTA scans from patients undergoing TAVI with SAPIEN 3 Ultra (S3U) prostheses were processed using a fully automated pipeline. Deep learning-based segmentation of cardiovascular structures, calcification detection, centerline extraction, landmark identification, and annular plane definition was implemented to quantify key annular and aortic root measurements and color-coded maps of lumen reduction and vessel diameter for vascular access. A multilayer perceptron classifier was trained to predict prosthesis size prior to the TAVI procedure. Results revealed that TAVI-TEC enabled pre-procedural measurements in approximately 2-6 min. Strong agreement with clinician-derived measurements was observed for annular area (coefficient of concordance, CCC = 0.934; interclass correlation coefficient, ICC = 0.935; R² = 0.881) and perimeter (CCC = 0.909; ICC = 0.909; R² = 0.854). The valve-size prediction model achieved a classification accuracy of 77.1% (95% CI: 70.1-83.9%) with the clinically selected and implanted valve size, with most discordances occurring between adjacent prosthesis sizes. These findings support the technical feasibility and promising initial performance of TAVI-TEC. Prospective multicenter and external validation, including additional valve platforms, will be required before routine clinical implementation and before its effects on operator variability and clinical workflow can be established.
-
4. Prognostic impact of severe malnutrition in dialysis patients who underwent transcatheter aortic valve replacement.
4. 严重营养不良对接受经导管主动脉瓣置换术的透析患者的预后影响PMID:日期:2026-09-19Patients with aortic stenosis who are undergoing dialysis are typically considered to be at very high surgical risk. Malnutrition is reported to be significantly associated with all-cause mortality and cardiovascular events in patients undergoing transcatheter aortic valve replacement (TAVR). Although patients with end-stage renal disease undergoing dialysis have poorer outcomes after TAVR, the prognostic effect of nutritional status in this high-risk population remains unclear. Thus, we aimed to investigate the prognostic impact of nutritional status in dialysis patients who underwent TAVR. This retrospective observational study included 106 dialysis patients who underwent TAVR at Tokyo Women's Medical University. Patients were categorized into four groups according to their Geriatric Nutritional Risk Index (GNRI) values: <82, 82-<92, 92-98, and >98, reflecting severe, moderate, mild, and no nutritional risks, respectively. The primary outcome measure was the all-cause mortality. During a median follow-up of 367 days, all-cause mortality was observed in 35.9% of the overall cohort. Risk stratification according to GNRI was significantly associated with prognosis (log-rank p < 0.001). Notably, patients with severe malnutrition (GNRI <82) had higher mortality than those in other GNRI categories. Nutritional stratification based on GNRI is a useful prognostic indicator. GNRI may provide complementary prognostic information for risk assessment in this high-risk population.
-
5. Sub-acute clinical leaflet thrombosis after transcatheter aortic valve implantation under direct oral anticoagulants.
5. 直接口服抗凝药下经导管主动脉瓣植入术后亚急性临床小叶血栓形成PMID:日期:2026-09-17The incidence of leaflet thrombosis following transcatheter aortic valve implantation is about 1% and is generally effectively treated with direct oral anticoagulants (DOACs). However, there are limited reports on the occurrence of HALT whilst on DOACs and its treatment.
-
6. Snare-assisted retrieval of a disconnected 2.25-mm rotablator burr with guide-extension counter-support.
6. 借助圈套器辅助及导引导管延长反向支撑技术取出脱离的PMID:日期:2026-09-16该文献暂无摘要。
-
7. Ten-year survival after stenting the proximal left anterior descending coronary artery with new-generation drug-eluting stents.
7. 使用新一代药物洗脱支架对左前降支近端冠状动脉进行支架置入术后的十年生存率PMID:日期:2026-09-16Percutaneous coronary intervention (PCI) of the proximal left anterior descending artery (p-LAD) is often considered a high-risk procedure, as the LAD supplies a substantial proportion of the myocardium. For most chronic coronary syndrome (CCS) patients with p-LAD target lesions, guidelines do not favor PCI over CABG, or vice versa. Long-term clinical data is lacking in new-generation drug-eluting stents (DES) used in p-LAD lesions. Therefore, we aimed to assess 10-year survival following PCI of the p-LAD versus other segments. We assessed patient-level data of consecutive all-comers, treated at Thoraxcentrum Twente with new-generation DES in the TWENTE I-III trials. Previous CABG or left main treatment were excluded. The primary endpoint was 10-year survival. Additionally, 5-year clinical events were assessed, including composite endpoints target lesion failure (TLF) and patient-oriented composite endpoint (POCE). Of all 4,467 patients, 1,244(27.8%) were treated for p-LAD lesions, while 3,223(72.2%) were treated exclusively for non-p-LAD lesions. After 10 years, all-cause mortality showed a numerically higher incidence in the p-LAD group, which was not statistically significant (24.0% vs. 22.3%; adjusted HR:1.05 95%CI 0.91-1.21, p=0.52). Furthermore, similar 5-year TLF and POCE rates were observed for both groups. In CCS patients, subgroup analyses showed no differences in 10-year survival by lesion location. Yet, the p-LAD group showed significantly lower 5-year repeat revascularization rates. P-LAD lesion location may not independently influence 10-year survival after PCI, both in all-comers and CCS patients. Yet, among CCS patients, 5-year repeat revascularization rates were lower in those treated for p-LAD lesions.
-
8. Ten-year outcomes after percutaneous coronary intervention with drug-eluting stents for bifurcation lesions: insights from the DECADE cooperation.
8. 药物洗脱支架经皮冠状动脉介入治疗分叉病变的十年结局:来自DECADE合作研究的见解PMID:日期:2026-09-10Patients treated with percutaneous coronary intervention (PCI) for bifurcation lesions have an increased risk of recurrent cardiac events. However, there are limited data on long-term outcomes after PCI with drug-eluting stents (DES) for bifurcation lesions. We sought to compare the long-term outcomes after DES PCI for bifurcation and non-bifurcation lesions among patients included in the Adverse Events and Coronary Artery Disease Progression (DECADE) cooperation, a pooled analysis of individual patient data from randomized controlled trials on DES platforms with a follow-up of 10 years. In the current analysis, patients undergoing PCI with DES were grouped according to whether the treated lesion was classified as a bifurcation or not. The main outcomes were cardiovascular death, myocardial infarction (MI) and target lesion revascularization (TLR) through to 10 years after PCI. Among the total of 6,617 patients included in this study, 1,580 patients underwent PCI of at least one bifurcation lesion and 5,037 patients underwent PCI of non-bifurcation lesions. Through to 10-year follow-up, cardiovascular death (adjusted hazard ratio [HR], 1.08 [95% CI, 1.03-1.14]) and TLR (HR, 1.50 [95% CI, 1.46-1.53]) occurred significantly more often after bifurcation PCI than after non-bifurcation PCI. Patients receiving a bifurcation PCI had a higher risk of MI at 10 years (HR, 1.42 [95% CI, 1.12-1.80]), with the highest risk within 30 days after PCI (HR, 2.14 [95% CI, 1.90-2.42]). In conclusion, patients who receive a PCI with a DES for a bifurcation lesion are at an increased risk of cardiovascular death, MI and TLR at 10-year follow-up.
-
9. Long-term outcomes after balloon- or self-expandable transcatheter aortic valve replacement in small aortic annuli.
9. 小主动脉瓣环患者接受球囊扩张式或自膨胀式经导管主动脉瓣置换术后的长期结局PMID:日期:2026-09-10Transcatheter aortic valve replacement (TAVR) is an established treatment for severe aortic stenosis. In patients with small aortic annuli (SAA), self-expandable valves (SEV) provide better hemodynamic performance than balloon-expandable valves (BEV); however, long-term outcomes remain unclear. We retrospectively analyzed 564 consecutive patients with SAA who underwent TAVR with follow-up of > 5 years, comparing BEV (n = 476) and SEV (n = 88). After propensity score (PS) matching, 84 patients were included in each group. Clinical outcomes were evaluated over a median follow-up of 2,134 days. Sensitivity analyses using inverse probability of treatment weighting were also performed. SEV was more frequently selected in patients with more severe baseline AS. SEV demonstrated more favorable post-procedural hemodynamics; BEV was associated with lower paravalvular leakage, whereas the difference in permanent pacemaker implantation was attenuated after PS matching. In the overall and propensity score-matched cohorts, there were no significant differences between BEV and SEV with respect to all-cause death, cardiovascular death, or first heart failure hospitalization. Moderate or greater hemodynamic valve deterioration incidence did not differ between groups in the overall (log-rank test, p = 0.372) or PS-matched cohort (log-rank test, p = 0.182). BVF events were rare in the overall cohort, and no BVF events occurred in the PS-matched cohort. SEV was associated with superior postprocedural hemodynamics; however, no significant differences in long-term clinical outcomes were observed compared with BEV. These findings underscore the need for further investigations using larger cohorts and contemporary devices to validate long-term comparative outcomes of BEV and SEV in patients with SAA.