Journal of Biophotonics生物光子学杂志
Journal of Biophotonics(英文缩写 J BIOPHOTONICS),ISSN 1864-063X,eISSN 1864-0648,中文译名:生物光子学杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 3.390 | Q2 |
| 2022 | 2.800 | Q2 |
| 2023 | 2.000 | Q3 |
| 2024 | 2.300 | Q3 |
| 2025 | 2.000 | Q3 |
Journal of Biophotonics 最新收录文献
-
1. Two-Photon Fluorescence and Second-Harmonic Generation Microscopy: Principles and Biomedical Applications.
PMID:日期:2026-09-29Two-photon microscopy (TPM) has revolutionized biological imaging by enabling high-resolution, deep-tissue visualization with reduced photobleaching and photodamage. This review discusses complementary nonlinear optical imaging modalities such as two-photon fluorescence (TPF), second-harmonic generation (SHG), and fluorescence lifetime imaging (FLIM) microscopy that together provide structural, molecular, and metabolic information. The review begins by introducing the basic principles, instrumentation, and capabilities of two-photon fluorescence microscopy and FLIM. Followed by the development of SHG microscopy, highlighting advances from conventional SHG imaging to polarization-resolved, circular dichroism, and Stokes-Mueller polarimetric approaches. The biomedical applications of these complementary techniques are subsequently discussed, followed by an overview of multimodal imaging strategies that combine structural, molecular, and functional information. Collectively, these modalities represent a versatile and rapidly evolving imaging toolkit with broad potential to advance biomedical research, disease diagnosis, and precision medicine.
-
2. Skin Color Bias in Neonatal Transcutaneous Bilirubin Measurement: A Diffuse Reflectance Spectroscopy Approach With Melanin Correction.
2. 新生儿经皮胆红素测量中的肤色偏差:一种带黑色素校正的漫反射光谱方法PMID:日期:2026-09-29Commercial jaundice meters rely on reflectance data from specific wavelengths for Transcutaneous bilirubin (TcB) measurements. However, skin color bias is introduced due to melanin contribution. In this study, we evaluated melanin concentration as an objective indicator of neonatal skin pigmentation and assessed the performance of melanin corrected TcB measurements (TcB). A total of 333 neonates were categorized into four groups using the Neomar skin color scale. Melanin concentration estimated from neonatal reflectance spectra strongly correlated with Neomar classification (Spearman's r = 0.90), with group differences confirmed by Kruskal-Wallis and Dunn's tests. TcB values showed good agreement with total serum bilirubin (TSB) across all color groups with minimal bias (-0.06 to 0.11 mg/dL). Compared with commercial TcB readings, skin color bias is reduced, particularly in the darker groups (colors 3 and 4). Chromophore-decoupled diffuse reflectance spectroscopy offers a skin color unbiased, clinically reliable approach for TcB measurements across diverse populations.
-
3. Study of a Frugal Design Picosecond Laser System for Laser-Assisted Corneal Surgery.
3. 用于激光辅助角膜手术的节俭设计皮秒激光系统研究PMID:日期:2026-09-28Femtosecond lasers have long been the gold standard for corneal laser-assisted surgery, but their high cost limits widespread use. This study challenges their supremacy by investigating a cost-effective alternative: a frugal all-fiber picosecond laser source. We first conduct a pump-probe experiment to characterize cavitation bubbles in water based on the laser pulse's temporal profile. Picosecond pulses concentrate energy in a confined volume near the focal point, allowing for more precise material interaction than femtosecond pulses. A distortion in the temporal profile, often seen as a flaw, paradoxically further reduces cavitation bubble size. These findings are then applied to ex vivo porcine cornea cutting tests. Results show that 1.5 ps pulses with a distorted profile create sharp, consistent cuts. This study reveals that a cost-effective picosecond laser can rival femtosecond lasers in precision, paving the way for more accessible corneal laser-assisted surgery.
-
4. PEGylated Superparamagnetic Iron Oxide Nanoparticles as Contrast-Enhancing Agents for Swept-Source Optical Coherence Tomography of Biological Tissue.
PMID:日期:2026-09In this work, the effect of surface modification of superparamagnetic iron oxide nanoparticles (SPIONs) with polyethylene glycol (PEG) on contrast enhancement in swept-source optical coherence tomography (SS-OCT) is investigated. The bare and PEGylated SPIONs were prepared by the co-precipitation method from an aqueous solution of an Fe(III) salt. They were characterized by UV-DRS, Raman spectroscopy, FTIR, TEM, and VSM to determine their physicochemical properties. The performance of ex vivo imaging was evaluated in chicken breast tissue with B-scan SS-OCT at various exposure times (0, 10, 20, 30, 40, and 50 min), and the contrast enhancement was investigated by measuring the scattering coefficient. The brightness of bare SPIONs was low, and the penetration into tissues was slow. PEG-SPIONs, on the other hand, showed better optical stability, penetration, enhanced scattering, and brighter SS-OCT images. The scattering coefficient (mm) of PEG-SPION-treated tissue increased with exposure time, indicating its effectiveness as a tissue contrast agent.
-
5. Household LED Light-Mediated Photodynamic Therapy for Effective Inhibition of Multidrug-Resistant Staphylococcus aureus.
5. 家用LED光介导的光动力疗法有效抑制多重耐药金黄色葡萄球菌PMID:日期:2026-09This study evaluates toluidine blue-O and curcumin (CUR) as photosensitizers (PSs) for photodynamic therapy against Staphylococcus aureus, each activated using a household light-emitting diode bulb selected to approximate the absorption profiles of the respective PS. The colony-forming unit (CFU) assay revealed time-dependent bacterial reductions, achieving 4.85 log CFU/mL at 10 min for TBO and 4.26 log CFU/mL at 15 min for CUR under their respective LED illumination conditions. Extracellular polymeric substance production decreased by 96.22% with TBO and 48.98% with CUR, accompanied by enhanced reactive oxygen species generation. Confocal laser scanning microscopy provided semi-quantitative evidence of an increased dead-to-live cell ratio following PDT. In vivo results, supported by histopathological examination and cytokine expression profiling, demonstrated modest but significant bacterial load reduction and improved tissue architecture following TBO- and CUR-mediated PDT. These findings suggest that readily available household LED bulbs may serve as accessible illumination sources for aPDT against S. aureus.
-
6. Photobiomodulation Triggers M1/M2 Macrophage Polarization in Zymosan-Induced Acute Arthritis in Mice.
6. 光生物调节在小鼠酵母聚糖诱导的急性关节炎中触发M1/M2巨噬细胞极化PMID:日期:2026-09To investigate whether photobiomodulation (PBM) modulates macrophage polarization in zymosan-induced acute joint inflammation, promoting an M1 to M2 phenotype shift. Mice received intra-articular zymosan and PBM (830 nm, 10 mW) at 3 and 30 J/cm. Euthanasia occurred at 24, 48, and 72 h. Polarization was assessed via mRNA levels and protein expression. At 24 h, both fluences downregulated iNOS and Arg-1 mRNA. The 30 J/cm dose sustained steady-state mRNA levels through 72 h. Immunohistochemistry showed that 3 J/cm reduced M1 cells at 24 h, while 30 J/cm was more effective in promoting M2 polarization at 48 and 72 h. Predominance of M2 over M1 macrophages was observed in all treated groups. PBM may modulate acute joint inflammation by driving a phenotypic switch from M1 to M2 macrophages. These regulatory effects depend on irradiation conditions, with higher fluence (30 J/cm) sustaining a durable pro-resolutive cellular profile.
-
7. Deep Learning Framework for 3D Fluorescence Lifetime Estimation.
7. 用于三维荧光寿命估计的深度学习框架PMID:日期:2026-09Fluorescence lifetime imaging has emerged as a powerful tool for quantitatively assessing the molecular environment of live tissues. While fluorescence lifetime microscopy is a maturing field, achieving effective 3D imaging in deep tissues remains challenging due to high scattering. In this study, we present a deep neural network-based approach, AUTO-FLI, which enables both 3D intensity and quantitative lifetime reconstructions at centimeter depths. Unlike conventional approaches that estimate lifetime from 2D measurements prior to reconstruction, AUTO-FLI directly recovers voxel-wise lifetime within a three-dimensional domain. The proposed method incorporates an in silico framework to generate fluorescence lifetime data for training and validation. The model is further validated using experimental data acquired on an anatomically accurate mouse-mimicking phantom. The results demonstrate accurate 3D estimates of both intensity and lifetime distributions in highly scattering media, supporting fluorescence lifetime-based molecular imaging at mesoscopic and macroscopic scales, with potential applications in pre-clinical research and fluorescence-guided surgery.
-
8. Enhancement of Harvested Islet Functionality Through Photostimulation.
8. 通过光刺激增强收获胰岛的功能PMID:日期:2026-09Allogeneic islet transplantation is a promising treatment for Type I diabetes, but its success is limited by islet loss during isolation, purification, and engraftment, resulting in variable long-term insulin independence. Our previous studies demonstrated that photobiomodulation (PBM) significantly enhances insulin and glucagon secretion in pancreatic cells, likely through modulation of ATP production and calcium signaling pathways involved in hormone release. Building on these mechanistic findings, we investigated whether PBM could similarly improve the functionality of whole islets before transplantation. Mouse islets were isolated by pancreatectomy, cultured ex vivo, and treated daily with PBM for 7 days. Fluorescence imaging and functional assays were used to assess insulin expression and secretion. PBM significantly enhanced insulin secretion, with an approximately twofold increase observed after 3 days of treatment. These findings support PBM as a promising, noninvasive approach for improving islet function before transplantation.
-
9. Monte Carlo-Based Optimization of Multi-Source Illumination for Photoacoustic Signal Generation in Human Gray-Matter Vessels.
PMID:日期:2026-09Effective excitation of cerebrovascular photoacoustic signals is limited by superficial tissue attenuation and illumination geometry. This paper proposes a multi-source illumination evaluation method for gray-matter vessel targets based on Monte Carlo light transport and photoacoustic initial-pressure calculation using a simplified multilayer brain model for screening and a Tissue Probability Map (TPM) brain model for validation. The dual Collimated Gaussian source with 15° symmetric incidence along the Y direction performed best in the regular layered model, whereas the dual Pencil Array source with 20° symmetric incidence along the Y direction was optimal in the TPM model. These results suggest that regular layered models are suitable for preliminary screening, but the final illumination scheme should be revalidated under anatomical constraints. This study provides a theoretical reference for optimizing optical-source configurations in human brain photoacoustic imaging.
-
10. Dual-Wavelength Super-Pulsed Diode Laser (810 and 980 nm) for Mucocele Excision in the Lower Lip: Case Report.
10. 双波长超脉冲半导体激光(810和980纳米)用于下唇黏液囊肿切除术:病例报告PMID:日期:2026-09This report describes the excisional biopsy of a lower lip mucocele using a dual-wavelength super-pulsed diode laser (810/980 nm). The procedure was performed under local anesthesia using a 400 μm fiber tip with peak power of 100 W, pulse frequency of 20 Hz, pulse width of 0.05 ms, and average power of 1.2 W. The super-pulsed emission enabled precise tissue incision, effective intraoperative hemostasis, and clear visualization of the surgical field. The excised specimen showed preserved morphology without carbonization, allowing histopathological confirmation of mucocele. After excision, photobiomodulation therapy was applied using a 7-mm adapter (0.3 W, 2 J, 7 s per point, 5.5 J/cm) to promote postoperative analgesia and tissue repair. Healing was uneventful, with no postoperative pain, edema, or recurrence at 90 days. The dual-wavelength super-pulsed diode laser represents a minimally invasive approach for oral mucocele excision while preserving tissue integrity for histopathological analysis.