General Thoracic and Cardiovascular Surgery普通胸心血管外科
General Thoracic and Cardiovascular Surgery(英文缩写 GEN THORAC CARDIOVAS),ISSN 1863-6705,eISSN 1863-6713,中文译名:普通胸心血管外科 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 1.227 | Q4 |
| 2022 | 1.200 | Q4 |
| 2023 | 1.100 | Q3 |
| 2024 | 1.300 | Q3 |
| 2025 | 1.500 | Q3 |
General Thoracic and Cardiovascular Surgery 最新收录文献
-
1. Physiological response following inhaled nitric oxide administration during one-lung ventilation in minimally invasive cardiac surgery: an exploratory prospective cohort study.
PMID:日期:2026-10-03This study aimed to evaluate the physiological responses following inhaled nitric oxide (iNO) administration in patients with one-lung ventilation (OLV)-related hypoxemia accompanied by pulmonary hypertension in minimally invasive cardiac surgery (MICS). This exploratory prospective cohort study enrolled 63 consecutive patients who underwent MICS. Patients who developed post-cardiopulmonary bypass (CPB) OLV-related hypoxemia with pulmonary hypertension received iNO. The evaluation included changes in PaO/FiO and mean pulmonary artery pressure (mPAP). Additionally, multivariable logistic regression analysis was performed to examine clinical factors associated with iNO initiation. Overall, 30 patients (47.6%) received iNO. PaO/FiO significantly increased following iNO administration (70 [61-80] to 85 [72-102], P = 0.011), while mPAP remained unchanged (24 [23-26] to 25 [22-28] mmHg, P = 0.564). Multivariable analysis identified female sex (odds ratio [OR]: 5.00), higher body mass index (OR: 1.36), and prolonged CPB time (OR: 1.03) as associated factors for iNO initiation (area under the curve: 0.822). All patients with a second aortic clamp or pre-CPB hypoxemia met the initiation criteria and received iNO. Post-CPB OLV-related hypoxemia accompanied by pulmonary hypertension occurs frequently during MICS. The observed increase in oxygenation following iNO administration suggests its potential utility for respiratory management in MICS, warranting future large-scale, multicenter investigations.
-
2. Robotic left S10 segmentectomy preserving an A9 branch missed on initial 3D-CT reconstruction: a lung base-flip approach.
PMID:日期:2026-09-29Accurate anatomical assessment is essential for precise pulmonary segmentectomy. We report a robotic left S10 segmentectomy in a 72-year-old woman in whom the initial three-dimensional computed tomography (3D-CT) reconstruction showed no pulmonary artery accompanying B9bii and focal irregularity of A10b. Re-evaluation of the contrast-enhanced CT images revealed a small A9bii arising from A10b that had not been depicted on the initial reconstruction. Manual correction of the 3D-CT images clarified the arterial anatomy and guided surgical planning. A lung base-flip approach provided a favorable caudal view of the deep A10b-A9bii bifurcation, enabling identification and preservation of A9bii. This case highlights the importance of recognizing anatomical discrepancies on reconstructed images, reassessing the CT images, and selecting an appropriate surgical approach to preserve anomalous pulmonary arterial branches.
-
3. Comment on "mid-term hemodynamic and structural valve outcomes of bovine pericardial and porcine bioprostheses after surgical aortic valve replacement".
3. 关于“牛心包与猪生物瓣膜在外科主动脉瓣置换术后中期血流动力学及瓣膜结构结局”的评论PMID:日期:2026-09-24该文献暂无摘要。
-
4. Landiolol or a perioperative care bundle? Interpreting POAF prevention after OPCAB.
PMID:日期:2026-09-23该文献暂无摘要。
-
5. Robotic minimally invasive direct coronary artery bypass (MIDCAB): a standardised operative technique.
PMID:日期:2026-09-21Minimally invasive direct coronary artery bypass (MIDCAB) enables left internal mammary artery (LIMA) to left anterior descending artery (LAD) revascularisation without sternotomy or cardiopulmonary bypass. Robotic-assisted LIMA harvest improves visualisation and maximises conduit length while preserving the benefits of minimal access surgery. We describe a standardized technique for off-pump robotic-assisted MIDCAB (LIMA- LAD) developed in an experienced robotic coronary program, including operative setup, technical execution, postoperative care, and key considerations that allow reproducible outcomes.
-
6. Hypo-attenuated leaflet thickening after surgical aortic valve replacement with INSPIRIS RESILIA valve.
6. 使用INSPIRIS RESILIA瓣膜行外科主动脉瓣置换术后出现瓣叶低密度增厚PMID:日期:2026-09-17To investigate the incidence and early clinical impact of hypo-attenuated leaflet thickening (HALT) after surgical aortic valve replacement (SAVR) using the INSPIRIS RESILIA valve. Between August 2020 and January 2025, 182 patients underwent SAVR with the INSPIRIS RESILIA valve, of whom 121 (66.5%) underwent cardiac computed tomography 1 week postoperatively. Anticoagulation consisted of heparin (target activated partial thromboplastin time, 1.5-2.0× control) followed by warfarin (target prothrombin time-international normalized ratio [PT-INR], 1.6-2.5). Parameters were compared between the HALT and non-HALT groups. HALT was detected in 22.3% (27/121) of patients. Among warfarin-treated patients (n = 94), mean PT-INR was 1.7 in the HALT group and 1.8 in the non-HALT group (p = 0.61). Patients with HALT were older (76.2 vs. 73.0 years, p = 0.10), and sex-adjusted odds ratio of HALT was 4.68 for patients aged ≥ 80 years as compared with those aged < 70 years (p = 0.03). Those with HALT had lower body surface area (1.46 vs. 1.58 m, p = 0.002). HALT was not associated with impaired early prosthetic valve function, and no patient had a mean pressure gradient > 20 mmHg. No in-hospital deaths or thromboembolic events were reported. No cerebral infarction occurred in the HALT group, whereas two occurred in the non-HALT group (p = 1.00). HALT occurred in approximately one-fifth of patients after SAVR with the INSPIRIS RESILIA valve. No signal of an increased risk of thromboembolic events associated with HALT was observed in this small cohort with a short-term follow-up.
-
7. Methodological considerations in comparing intraoperative CT and VAL-MAP workflows.
7. 比较术中CT与VAL-MAP工作流程的方法学考量PMID:日期:2026-09-16该文献暂无摘要。
-
8. Sealing strength and application efficiency of the microbubble fibrin sealant technique: influence of PGA sheet type in an ex vivo porcine lung model.
8. 微泡纤维蛋白密封剂技术的密封强度和应用效率:离体猪肺模型中PGA片类型的影响PMID:日期:2026-09-16We previously proposed the microbubble fibrin sealant application technique (microbubble technique) for the precise and efficient delivery of fibrinogen to air leak sites. However, its sealing strength and application efficiency are still unclear. This study aimed to assess the non-inferiority of the microbubble technique in sealing strength, the influence of polyglycolic acid (PGA) sheet type, and its effect on reducing fibrin sealant runoff. Pleural defects were created in ex vivo porcine lungs. Fibrin sealant was applied using either the conventional or microbubble technique with two types of PGA sheets. Seal-breaking pressure was measured, and the non-inferiority of the microbubble technique was assessed. The interaction between the application technique and the PGA sheet type was analyzed. In addition, the fibrin sealant runoff was evaluated on an inclined lung surface. Using the Neoveil® PGA sheet, the microbubble technique demonstrated seal-breaking pressure not inferior to that of the conventional technique (40.2 ± 8.4 vs. 40.9 ± 6.0 cmHO; mean difference - 0.72 cmHO; one-sided 95% confidence interval - 3.62 to infinity). The Neoveil® nano NJ type PGA sheet improved sealing strength with the conventional technique, but reduced it with the microbubble technique. A significant interaction between the PGA sheet type and the application technique was observed (P < 0.001). Histological analysis supported these findings. The microbubble technique significantly reduced fibrin sealant runoff (P < 0.001). The microbubble technique demonstrated sealing strength comparable to that of the conventional technique while reducing fibrin sealant runoff. However, sealing performance appeared to depend on the PGA sheet type.
-
9. Effectiveness of free pericardial fat pad reinforcement for air leak control in pulmonary lobectomy.
9. 游离心包脂肪垫加固在肺叶切除术中控制漏气的有效性PMID:日期:2026-09-15Intraoperative management of air leak is essential for favorable recovery after lung cancer resection. We present our approach using a free pericardial fat pad (FPFP) for injured lung parenchyma and analyze the postoperative course and radiological changes over time to evaluate the usefulness of this method. From January 2020 to December 2023, 345 pulmonary lobectomies were performed for primary lung cancer. Postoperative course was compared between patients who received an FPFP for intraoperative air leak management (FPFP group, n = 63) and those managed without an FPFP (non-FPFP group, n = 282). Time-dependent radiological changes in the implanted FPFP were evaluated in 47 patients with computed tomography scans available at 6, 12, and 24 months postoperatively. Although the drainage duration differed significantly between the FPFP and non-FPFP groups (P = 0.001), the postoperative hospital stay (P = 0.257) and occurrence of prolonged air leak (P = 0.163) were comparable. Radiological analysis showed that the implanted FPFP gradually shrank over time (P < 0.001). Despite this change, no complications related to FPFP shrinkage were observed. Harvesting and implanting the FPFP was straightforward and easy to perform. Although the implanted FPFP gradually decreased in size on computed tomography, this did not adversely affect the postoperative course. FPFP application is a promising clinical option for managing intraoperative air leak in pulmonary lobectomy.
-
10. Comments on "Intraoperative assessment of pulmonary fissure morphology in a large surgical series: implications for operative strategy".
10. 对“大型手术系列中肺裂形态的术中评估:对手术策略的启示”一文的评论PMID:日期:2026-09-14该文献暂无摘要。