Expert Review of Medical Devices医疗器械专家评论
Expert Review of Medical Devices(英文缩写 EXPERT REV MED DEVIC),ISSN 1743-4440,eISSN 1745-2422,中文译名:医疗器械专家评论 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 3.439 | Q3 |
| 2022 | 3.100 | Q3 |
| 2023 | 2.900 | Q3 |
| 2024 | 2.700 | Q3 |
| 2025 | 2.800 | Q3 |
Expert Review of Medical Devices 最新收录文献
-
1. Safety and effectiveness of ultrasound-guided versus open carpal tunnel release: a systematic review and meta-analysis of prospective controlled studies.
PMID:日期:2026-10-01This systematic review and meta-analysis compared the safety and effectiveness of ultrasound-guided carpal tunnel release (UGCTR) and open carpal tunnel release (OCTR). We searched Medline, Embase, and the Cochrane Central Register of Controlled Trials for prospective studies comparing blade-based UGCTR and OCTR. Random-effects meta-analysis compared time to return to normal activities; Boston Carpal Tunnel Questionnaire Symptom Severity (BCTQ-SSS) and Functional Status (BCTQ-FSS) scores, pain severity, and patient satisfaction at 3 and 12 months; and complications through 12 months. Six studies (four randomized; 749 patients) were included. UGCTR was associated with earlier return to normal activities than OCTR (mean difference: -13.9 days; 95% CI: -27.5 to -0.3; = 0.045), although this estimate was sensitive to removal of individual studies. No significant group differences were observed in BCTQ scores, pain severity, or patient satisfaction at 3 or 12 months, and heterogeneity was considerable for most outcomes. Complication rates did not significantly differ (4.4% vs. 4.1%; risk ratio: 1.11; 95% CI: 0.55 to 2.25; = 0.77). Compared with OCTR, UGCTR was associated with earlier return to normal activities, with no significant group differences in other outcomes. The findings are limited by considerable heterogeneity and few eligible studies.
-
2. Routine microaxial left ventricular support during nonemergent high-risk PCI: an updated systematic review and meta-analysis with Bayesian and grade methodologies.
2. 非急诊高风险PCI中常规微轴左心室支持:一项采用贝叶斯和GRADE方法学的更新系统评价与Meta分析PMID:日期:2026-09-24Microaxial left ventricular support (MLVS; Impella, Abiomed) is increasingly used during nonemergent high-risk percutaneous coronary intervention (HR-PCI), although randomized evidence remains limited and device-related complications are a concern. PubMed/MEDLINE, Scopus, Web of Science, and the Cochrane Library were searched from inception through March 2026 for randomized and comparative observational studies of MLVS versus control during nonemergent HR-PCI. Random-effects meta-analysis, subgroup and sensitivity analyses, Bayesian modeling, risk-of-bias assessment, and GRADE were performed. Ten studies including 7,875 patients were analyzed. MLVS was not associated with lower all-cause mortality overall (RR 1.17, 95% CI 0.81-1.67; I = 82.1%). Exploratory analyses showed higher mortality estimates in randomized trials (RR 1.44, 95% CI 1.05-1.97) and studies of planned pre-PCI support (RR 1.52, 95% CI 1.17-1.97). Bayesian analysis yielded a median RR of 1.14 (95% CrI 0.80-1.65; Pr[RR >1]=77.2%). Myocardial infarction, stroke/cerebrovascular events, and MACE/MACCE were not significantly different, while major bleeding was increased (RR 1.92, 95% CI 1.14-3.23). Current evidence does not support routine prophylactic MLVS during nonemergent HR-PCI. Selective use may remain appropriate, but further adequately powered randomized trials are needed. PROSPERO CRD420261358349.
-
3. Use of neurostimulation in patients with treatment-resistant depression: current options and future directions.
PMID:日期:2026-09-17Treatment‑resistant depression (TRD) reflects persistent dysfunction across large‑scale neural networks despite adequate pharmacotherapy. Neuromodulation offers mechanistically grounded interventions capable of directly modulating circuit‑level abnormalities implicated in TRD. This expert review synthesizes established, emerging, convulsive, and invasive neuromodulation modalities, including repetitive transcranial magnetic stimulation (rTMS), theta burst stimulation, accelerated TMS, deep TMS, transcranial electrical stimulation, temporal interference stimulation, photobiomodulation, low-field magnetic stimulation, transcranial focused ultrasound, electroconvulsive therapy, magnetic seizure therapy, vagus nerve stimulation, and deep brain stimulation. For each modality, technological foundations, mechanisms, efficacy, safety, and implementation considerations are summarized. Recent regulatory approvals of at-home prescription devices highlight the growing role of accessible home-based neuromodulation. Comparative effectiveness across effect size, tolerability, cost, and patient selection is reviewed. Advances in connectivity-informed targeting, tractography-guided neuromodulation, dose optimization, and biomarker-driven stratification illustrate the transition toward precision platforms. Literature for this review was identified through a non-systematic PubMed search. Neuromodulation is evolving from a last-line intervention to a precision tool for circuit recalibration. Future progress will be driven by individualized targeting, closed-loop and multimodal stimulation, mechanistic trials, and scalable home-based delivery models. International collaborative research will be essential for validating biomarkers and accelerating development of next-generation circuit-based therapeutics.
-
4. A device profile on the MAGiC ablation catheter for treatment of cardiac arrhythmia.
4. MAGiC消融导管用于治疗心律失常的设备配置文件PMID:日期:2026-09-14Catheter ablation is standard of care for cardiac arrhythmias, but conventional catheters are still limited by single-plane steering, variable tissue contact, and high irrigation demands, particularly in complex anatomy. Robotic magnetic navigation (RMN) addresses several of these constraints, but it has long depended on a first-generation radiofrequency catheter. This device profile reviews the design, mechanism of action, available clinical evidence, regulatory status and future development of the MAGiC magnetic ablation catheter, the first purpose-built catheter for the Stereotaxis RMN platform. The catheter is used across the full arrhythmia spectrum, including supraventricular tachycardias, atrial fibrillation, and ventricular arrhythmias, with complex and congenital anatomy among its most demanding applications. The evidence is drawn from its first-in-human study, supporting bench and platform data, and a structured search of the peer-reviewed literature. Early experience points to improved catheter stability, stable tip temperatures, and reduced irrigation relative to the predecessor RMN catheter. The evidence base remains small, single-arm and partly manufacturer-sponsored, however, and comparative and long-term data are not yet available.
-
5. Potential role of artificial intelligence in automating European Union medical device Regulation.
5. 人工智能在自动化欧盟医疗器械法规中的潜在作用PMID:日期:2026-08-31该文献暂无摘要。
-
6. Transcatheter tricuspid valve replacement for severe tricuspid regurgitation: current and future perspectives.
6. 经导管三尖瓣置换术治疗重度三尖瓣反流:现状与未来展望PMID:日期:2026-08-31Severe tricuspid regurgitation (TR) is common, undertreated, and associated with significant morbidity and mortality. Transcatheter tricuspid valve replacement (TTVR) has emerged as a promising option for patients unsuitable for surgical repair or transcatheter edge-to-edge repair. This review examines the innovation trajectory, current device landscape, patient selection, imaging guidance, procedure-specific challenges, and future perspectives of TTVR. A systematic literature search was performed using PubMed/MEDLINE, Embase, and ClinicalTrials.gov, covering publications from January 2015 to May 2025, using search terms including 'transcatheter tricuspid valve replacement,' 'TTVR,' 'tricuspid regurgitation,' and device-specific names. TTVR offers near-complete regurgitation elimination but remains anatomy- and mechanism-dependent. Its role is best defined in patients with anatomy unfavorable for repair. Optimal timing, device selection, antithrombotic management, and long-term durability require prospective validation through dedicated trials and head-to-head comparisons with repair strategies.
-
7. Validity and reliability of an inertial measurement unit motion sensor as a tool for measuring cervical spine range of motion.
PMID:日期:2026-08-28Accurate measurement of Cervical Range of Motion (CROM) is essential for quantifying motor deficits, designing interventions, and monitoring rehabilitation effectiveness. This study evaluated the validity and reliability of an Inertial Measurement Unit (IMU) (the Wiva Science) motion sensor, for assessing active CROM. Sixty participants (22 male, 38 female) were enrolled for the validity study and fifty (32 male, 18 female) for the reliability study. Active CROM was measured at peak-range (participant's maximum comfortable active movement) and mid-range (participant-estimated halfway movement) positions using the IMU sensor and the Zebris motion capture system simultaneously. For reliability, a single examiner recorded three repetitions of each movement within a predetermined range. Concurrent validity was excellent, with Pearson's r ranged 0.902-0.996 (bias 0.08-3.67). The Intraclass Correlation Coefficient (ICC) for the IMU sensor ranged from 0.66-0.96, indicating moderate to excellent reliability. The Standard Error of Measurement was 0.26°-1.02°, and the Smallest Detectable Change ranged 1.93%-20.21%. The IMU motion sensor is cost-effective tool for CROM assessment, but its validity and reliability must be treated with caution. While clinically applicable, adequate trunk stabilization is essential for accuracy. To optimize results, device calibration is recommended prior to measuring each individual movement along its respective axis.
-
8. Overcoming the opaque side of AI in healthcare: a lifecycle-based approach.
PMID:日期:2026-08-27Transparency has emerged as a foundational condition for trustworthy Artificial Intelligence (AI) in healthcare. Despite its centrality, practical approaches to systematically operationalize transparency across the entire lifecycle of AI-enabled medical devices remain fragmented and insufficiently structured. This work addresses this gap by proposing a lifecycle-oriented operational approach to guide the consistent implementation and evaluation of transparency in AI-based medical technologies. A narrative synthesis of regulatory texts, international standards, and scientific literature related to software as a medical device (SaMD), the EU Medical Device Regulation (MDR), the EU Artificial Intelligence Act (AI Act), data-protection rules, and relevant ISO/IEC guidance. Using a SaMD lifecycle framework, we mapped transparency requirements to practical development, validation, and governance activities across ideation, data and design inputs, risk management, implementation/verification, technical and clinical validation, market placement, maintenance, and disposal. Transparency must be engineered as a lifecycle property, not an afterthought. We propose nine operational measures - covering documented design assumptions and datasets, transparency-oriented risk and change control, traceability, subgroup and independent validation, usability-based explainability, calibrated clinical evaluation, structured labeling, version-controlled updates, and regulated end-of-life data handling - to support regulatory readiness, calibrated clinical trust, and safe real-world integration of AI in healthcare.
-
9. When the interface fails: a patient-safety hazard hidden by the assumption of human error.
PMID:日期:2026-08-15Medical-device safety surveillance is organized around two failure types: a device that malfunctions and a clinician who errs. A third category, harm arising at the interface between two individually compliant devices used in combination, fits neither model and is poorly captured. As combination and procedure-pack care becomes ubiquitous, the safety significance of this blind spot grows. This article examines why interface failure evades vigilance and incident-reporting systems, using the syringe-cannula junction in intraocular surgery as a documented exemplar. Evidence was identified through searches of PubMed/MEDLINE and Google Scholar (database inception to July 2026), the US FDA MAUDE adverse-event database, and professional-body safety publications, and comprises surveys, case series, health-economic and litigation analyses, and the small-bore connector (ISO 80369) standards literature. It argues that misattribution to human error is the principal mechanism of under-reporting and traces the resulting cost to patients and staff. Interface failure is a distinct and legitimate object of safety attention that current systems do not see. Progress depends less on new devices than on whether surveillance acquires a reporting category for combination failure, pursues buried signals through trend analysis, and brings standards attention to high-consequence junctions.