CONTACT DERMATITIS接触性皮炎
CONTACT DERMATITIS(英文缩写 CONTACT DERMATITIS),ISSN 0105-1873,eISSN 1600-0536,中文译名:接触性皮炎 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 6.419 | Q1 |
| 2022 | 5.500 | Q1 |
| 2023 | 4.800 | Q1 |
| 2024 | 4.600 | Q1 |
| 2025 | 4.100 | Q1 |
CONTACT DERMATITIS 最新收录文献
-
1. Patch Test Relevance and Systemic Exposure Pathways in Eczema Patterns Suspected of Systemic Contact Dermatitis.
PMID:日期:2026-10-04Systemic contact dermatitis (SCD) occurs when sensitised individuals react to an allergen delivered systemically. Indian data that relate clinical patterns, patch-test relevance and systemic exposures are limited. (i) Characterise the clinico-demographic profile of four eczema patterns historically linked to SCD-non-specific eczema, pompholyx, recalcitrant hand eczema and symmetrical drug-related intertriginous-flexural exanthema (SDRIFE), and (ii) map probable systemic exposure pathways for the six allergens selected a priori based on their relevance in Indian patch-test populations and their recognised or plausible systemic exposure pathways (para-phenylenediamine, nickel, parthenium, potassium dichromate, cobalt and Balsam of Peru). We performed a prospective observational study at a tertiary care centre in North India from July 2023 to July 2024. Consecutive patients ≥ 12 years with the target eczema patterns underwent detailed exposure history, Indian Standard Series patch testing and COADEX grading. Diagnosis of SCD required a relevant positive patch test, documented systemic exposure and temporal flare correlation. Oral provocation was not performed. Descriptive statistics were performed, with exploratory categorical comparisons using chi-square or Fisher's exact tests, as appropriate. One hundred patients (mean ± SD age 37.7 ± 14.7 years; 59% female) were enrolled. Clinical distribution was non-specific eczema 38%, pompholyx 32%, hand eczema 29% and SDRIFE-like eruption 1%. Patch tests were positive in 40%, and leading sensitisers were para-phenylenediamine 13%, nickel 9%, parthenium 9% and potassium dichromate 8%. Two women (2%; 95% CI 0.24%-7.04%) fulfilled the study's prespecified clinical criteria for SCD: one nickel-associated case classified as clinically definite and one garlic-associated case classified as probable. No SCD was diagnosed in pompholyx or hand eczema subgroups. Although clinically relevant contact sensitisation is frequently observed, only two of 100 patients fulfilled the study's clinical criteria for SCD. These findings support targeted patch testing and structured exposure assessment in specific eczema patterns associated with SCD. Larger prospective multicentre studies are needed to refine criteria and capture the true burden of disease.
-
2. High Frequency of Sensitisation to Decyl and Lauryl Glucoside in Routine Patch Testing in the Netherland.
PMID:日期:2026-10-04Contact allergy to the alkyl glucosides decyl and lauryl glucoside is increasingly recognized. To determine the frequencies of sensitization to decyl glucoside and lauryl glucoside, to assess changes over the study period, to characterize their co-reactivity pattern, to evaluate the clinical relevance of positive reactions and to investigate whether patients with an atopic history had an increased likelihood of sensitization. Retrospective study of routine testing with decyl glucoside 5% pet. and lauryl glucoside 3% pet. in a cohort of 4343 patients patch tested between 1 November 2019 and 5 January 2026. Positivity rates were 3.5% for decyl and 3.1% for lauryl glucoside; 5.2% of the patients reacted to at least one glucoside. Doubtful reactions (?+) were common (decyl glucoside 2.5%; lauryl glucoside 3.1%). 1.9% of the total cohort had reactions considered certainly or probably clinically relevant. Co-reactivity between decyl and lauryl glucoside occurred in 40%-47% of positive patients, and atopic history was associated with modestly increased odds of positivity. Contact allergy to alkyl glucosides was frequent in our patch test population. A substantial proportion of doubtful reactions and the virtual absence of strongly positive reactions suggest that the glucoside patch test materials used have irritant properties.
-
3. Occupational Exposure to Nickel and Cobalt From Hairdressing Tools: A Cross-Sectional Study in 58 Danish Salons.
PMID:日期:2026-10-04Hairdressers frequently perform wet work, which weakens the skin barrier. Repeated skin contact with metallic tools introduces an occupational allergen exposure. However, data on nickel and cobalt release from commonly handled cutting tools remain limited. To estimate nickel and cobalt spot-test positivity in hairdressing tools used in Danish hair salons. In this cross-sectional field study, 58 voluntarily participating Danish salons were visited from 1 March to 30 June 2026. Scissors, hair clippers and razors were each tested once for nickel with dimethylglyoxime and for cobalt with nitroso-R salt colorimetric spot tests. Among 266 tools (167 scissors, 95 hair clippers and 4 razors), 37 (13.9%) were positive to nickel and 18 (6.8%) to cobalt. Nickel positivity was 15.6% in scissors and 10.5% in hair clippers; cobalt positivity was 6.6% and 6.3%, respectively. At least one positive tool occurred in 22/58 (37.9%) salons for nickel and 12/58 (20.7%) for cobalt. Nickel and cobalt release from commonly used hairdressing tools is a prevalent occupational hazard. These findings underscore the necessity of proactive preventive strategies, such as careful material selection and stricter regulatory oversight.
-
4. Tin Sensitization in Belgium and the Netherlands: Complementary Findings From Two Independent Retrospective Studies.
PMID:日期:2026-09-23Tin is a known but traditionally considered infrequent contact allergen. In recent years, several case reports have reported clinically relevant reactions to tin-containing oral hygiene products, particularly toothpastes. To assess the prevalence and clinical relevance of tin sensitization in consecutive patch-tested patients, as well as in a selected cohort of patients referred because of suspected metal allergy or (peri)oral complaints. Two independent retrospective cohorts were analyzed: 1919 consecutive patch-tested patients from the University Hospital Antwerp, tested with different tin preparations and 536 selected patients from Amsterdam UMC, referred because of suspected metal allergy or (peri)oral complaints and patch tested with tin chloride. In the consecutive cohort, 128/1919 patients (6.7%) tested positive to at least one tin preparation, of whom 35 (27.3%) had clinically relevant sensitization. In the selected cohort, 61/536 patients (11.4%) were sensitized to tin, with 16/50 assessed patients (32.0%) considered clinically relevant. Amongst clinically relevant cases, (peri)oral involvement was the most common presentation in both cohorts, followed by periorbital dermatitis in the consecutive cohort. Tin sensitization appears to be more common than previously recognized. Although (peri)oral involvement was the predominant clinical presentation, periorbital dermatitis was also frequently observed amongst patients with clinically relevant sensitization.
-
5. Reproducibility of Patch Test Reactions and Interpretation of Doubtful Results: A Retrospective Study of Identical Haptens Tested Simultaneously in Different Series.
PMID:日期:2026-09-23Reproducibility of patch test reactions remains debated, and the clinical significance of doubtful (?+) reactions is unclear. To evaluate reproducibility of positive reactions to identical haptens tested simultaneously in different series and analyse doubtful reactions using paired co-reactivity patterns. Patch test data from consecutive patients tested during 2015-2025 were analysed retrospectively. Six haptens were evaluated at standard concentrations in petrolatum: hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral, HICC) 5% pet., Amerchol L-101 50% pet., lanolin alcohol 30% pet., hydroxyethyl methacrylate (HEMA) 2% pet., mercaptobenzothiazole (MBT) 2% pet. and Myroxylon pereirae resin (balsam of Peru, MPR) 25% pet. Reproducibility was hapten-dependent. HEMA and MBT showed substantial to almost perfect agreement. HICC showed substantial agreement but a significantly higher positivity rate in the perfume series than in the baseline series. Amerchol L-101, lanolin alcohol and MPR showed lower positive agreement and fair-to-moderate kappa values. Most doubtful reactions were isolated, particularly for Amerchol L-101 and lanolin alcohol, whereas 43.8% of doubtful HICC reactions in the baseline series were supported by perfume-series reactivity. Reproducibility was strongly hapten-dependent. In this dataset, paired co-reactivity provided clinical context for interpreting discordant positive and doubtful reactions.
-
6. Paraphenylenediamine Contact Allergy and Post-Diagnostic Outcomes: A Single-Centre Study From the United Kingdom.
PMID:日期:2026-09-22Paraphenylenediamine (PPD) is a potent allergen, frequently responsible for allergic contact dermatitis (ACD) from hair dyes and temporary 'black henna' tattoos. Misleading 'PPD-free' labelling may expose sensitised individuals to structurally related aromatic amines. To characterise clinical features, cross-reactivity and outcomes of patients diagnosed with PPD ACD following diagnosis of PPD allergy, and to evaluate the accuracy and safety of 'PPD-free' products marketed in the United Kingdom. Retrospective study of PPD positivity between 2018 and 2025 at a university hospital was conducted. Demographic, clinical and exposure data were extracted from records, and outcomes post-diagnosis were surveyed by telephone. Ingredient lists of permanent 'PPD-free' hair dyes/tints identified through a structured online search were reviewed for cross-reactive amines. Of 1306 patients tested for PPD over 7 years, 56 (4.3%) had a positive reaction. The mean age of affected patients was 49 years; 82% were female, and hair dye was the most frequently reported source of exposure (77%). Eight (14%) had occupational exposure. Among 37 tested to para-toluenediamine (PTD), 10 (27%) were positive. Among 31 followed up, 24 (77%) reported remission after avoidance. Only 1 of 10 permanent 'PPD-free' hair dyes/tints examined was found to be free of any potentially cross-reactive amines. PPD remains a prevalent allergen causing chronic and occupational ACD. 'PPD-free' products frequently contain cross-reactive amines, highlighting the need for improved labelling and careful counselling.
-
7. Smelly Pig Manure: A Hypothetical Explanation for Sodium Metabisulphite Contact Allergy Mimicking Atopic and Seborrheic Dermatitis.
7. 臭猪粪:亚硫酸氢钠接触过敏模拟特应性和脂溢性皮炎的假设性解释PMID:日期:2026-09-18该文献暂无摘要。
-
8. Allergic Contact Dermatitis in Children Over a 20-Year Period: A Danish Single-Centre Study.
PMID:日期:2026-09-16该文献暂无摘要。
-
9. Occupational Urticaria Caused by Different Platinum Group Elements (PGEs).
PMID:日期:2026-09-16该文献暂无摘要。