IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERINGIEEE 神经系统与康复工程汇刊
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING(英文缩写 IEEE T NEUR SYS REH),ISSN 1534-4320,eISSN 1558-0210,中文译名:IEEE 神经系统与康复工程汇刊 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 4.528 | Q1 |
| 2022 | 4.900 | Q1 |
| 2023 | 4.800 | Q1 |
| 2024 | 5.200 | Q1 |
| 2025 | 6.600 | Q1 |
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING 最新收录文献
-
1. Load-Decomposition Learning Enhances Ground Reaction Force Estimation Using IMUs.
1. 载荷分解学习提升基于惯性测量单元的地面反作用力估计PMID:期刊:日期:2026-10-01Accurate estimation of ground reaction forces (GRFs) is fundamental to gait analysis and supports functional gait assessment, surgical planning, and rehabilitation. We propose a physics-learning hybrid framework that combines linked-segment dynamics with a bidirectional long short-term memory network to estimate vertical GRFs (vGRFs) from seven inertial measurement units (IMUs). The learning module produces an unconstrained allocation variable that decomposes the physics-derived net force into limb-specific vGRFs. The framework was systematically evaluated against machine learning-based baselines, including MLP, LSTM, BiLSTM, and Transformer variants, using three datasets: two self-collected datasets comprising healthy individuals and individuals with unilateral transtibial amputation, and an independent public biomechanics dataset covering multiple walking speeds, ramps, and stairs. Evaluation included intra-subject, intersubject, cross-population, and between-day evaluations, as well as cross-task transfer. The proposed framework achieved an RMSE of 0.034 BW in intra-subject evaluation and 0.065 BW in inter-subject evaluation, both below the 0.10 BW high-accuracy reference, while maintaining high coefficients of determination (R = 0.994 and R = 0.978, respectively). These findings demonstrate that integrating biomechanical structure with data-driven learning can improve vGRF estimation performance in both intra- and inter-subject settings, while showing potential for transfer across populations, measurement sessions, and locomotor tasks. The framework therefore supports further development toward quantitative gait assessment and broader clinical applications.
-
2. Nanopatterned Black Silicon Electrodes for High-Charge-Density Intraspinal Microstimulation.
2. 用于高电荷密度脊髓内微刺激的纳米图案化黑硅电极PMID:期刊:日期:2026-09-30Restoring motor and sensory function after spinal cord injury (SCI) through intraspinal microstimulation (ISMS) has primarily focused on gray matter targets, while the longitudinally organized axon tracts of spinal cord white matter remain an underexplored route for activating ascending sensory and descending motor pathways. Tract-selective stimulation requires small electrode sites to confine the stimulation field, but miniaturization increases impedance and electrode polarization, limiting the charge that can be delivered from a fixed geometric footprint. To address this challenge, we developed platinum-coated black silicon (BSi-Pt) microelectrodes, in which cryogenically etched black silicon (BSi) nanostructures are conformally coated with platinum to increase electrochemical surface area within a fixed 30×30 μm footprint. Relative to thickness-matched, optimized flat Pt controls, BSi-Pt electrodes exhibited a ∼2.2-fold reduction in 1 kHz impedance. Fast- and slow-scan cathodal charge storage capacity (CSC) values for BSi-Pt were 3.12 mC/cm at 250 V/s and 22.3 mC/cm at 50 mV/s, corresponding to ∼3.8-and ∼2.3-fold increases, respectively. BSi-Pt electrodes achieved a water-window-based charge injection capacity (CIC) of 0.9 mC/cm and a charge injection limit (CIL) of ∼2.2 mC/cm, defined by the onset of nonlinearity in the input-output response. Finite element analysis (FEA) identified a ground-sheet return configuration that maintained field confinement comparable to a concentric-return configuration while doubling electrode density. Acute proof-of-concept experiments in rat spinal cord (n = 4) evoked propagating activity in the fasciculus gracilis and single-muscle EMG responses from dorsal corticospinal tract stimulation, while continuous pulsing at elevated charge density produced no measurable platinum dissolution. These findings establish BSi-Pt as a manufacturable, CMOS/MEMS-compatible platform for high-density tract-selective ISMS.
-
3. Sensory Survey 3D: an open source utility for the annotation of projected fields for sensory neural interfaces.
3. 感官调查3D:一个用于标测感觉神经接口投影场的开源工具PMID:期刊:日期:2026-09-28One goal of neuroprosthetics is to restore sensation to those who have lost it due to disease or injury. This is often accomplished with electrical stimulation of nervous tissue. Common approaches to quantifying evoked sensations for somatosensory prostheses involve asking participants to draw or annotate flattened, 2-dimensional (2D) representations of body parts, a process that can distort the true nature of the 3-dimensional (3D) projected fields. In particular, patches of skin between the fingers and toes or at the edge of the wrist often go unrepresented in 2D, leaving them unquantified. Here, we present a 3D annotation tool that allows participants to accurately report evoked sensations on any given body part. Patients implanted with either NeuroPort electrode arrays (Blackrock Neurotech) in Brodmann's Area 1 (N=2 male) or Composite Flat Interface Nerve Electrodes on the peripheral nerves of an amputated arm (N=2 male) were electrically stimulated and asked to annotate the location of the resulting sensations. In the first cohort, patients reported sensations on a generic hand using either a 2D or 3D interface. We found that participants reported consistent sensation locations between annotation methods when sensations were localized to central parts of the fingers and hand, visible in 2-dimensions. However, as expected, the 3-dimensional interface better captured sensations on the edges of or between fingers. In the second cohort, intact limbs were scanned and an iterative Procrustes alignment algorithm was used to warp and compare projected fields between patient-specific models. Our 3-dimensional annotation tool allows for more precise annotation of evoked sensations than 2-dimensional alternatives and facilitates rapid analysis across patients with different morphologies.
-
4. MF-PNet: A Lightweight Multi-Frequency Progressive Neural Network for Depression Classification Deployed on Wearable EEG Sensors.
4. MF-PNet:一种部署于可穿戴脑电传感器上的轻量级多频渐进神经网络用于抑郁症分类PMID:期刊:日期:2026-09-25Low-channel wearable EEG offers a compact acquisition configuration for depression recognition, but its limited spatial coverage and the computational constraints of edge devices present challenges for representation learning and embedded inference. This paper presents MF-PNet, a multi-frequency progressive neural network designed for three-channel EEG. Five frequency-specific branches process the canonical EEG bands in parallel, while a full-band branch progressively aggregates their representations through layer-wise lateral transfer and squeeze-and-excitation-based channel recalibration. Temporal and channel attention are further incorporated to emphasize informative EEG segments and frontal channels. Subject-level leave-one-subject-out cross-validation was conducted on a balanced in-house cohort of 146 participants. Across five random seeds, MF-PNet achieved an accuracy and F1-score of 98.8% ± 1.0% under auditory stimulation. Within-dataset evaluation on the independent Figshare and MODMA cohorts yielded accuracies of 92.1%±2.0% and 66.4%±6.5%, respectively. For embedded implementation, MF-PNet was distilled into a MobileNetV3-based student containing 75.51K parameters. The student achieved an accuracy of 99.3% ± 1.2%, and its INT8 representation retained an accuracy of 98.5% ± 0.9%. On the STM32U575CGT6 MCU, the implementation required 217.15KB of ROM and 215.78KB of RAM, with an inference latency of 45.99ms per 2-s EEG window and a power consumption of 43.2mW. The resulting framework integrates progressive cross-band EEG representation learning, teacher-student compression, INT8 quantization, and MCU execution into a unified pipeline for three-channel wearable EEG depression recognition.
-
5. Neuromuscular Adaptations in Degenerative Rotator Cuff Tears: Contributions of Aging and Pathology.
5. 退行性肩袖撕裂中的神经肌肉适应性改变:衰老与病理的贡献PMID:期刊:日期:2026-09-25Degenerative rotator cuff tear (RCT) is associated with impaired shoulder function; however, the extent to which altered neuromuscular coordination reflects aging-related changes or pathology-associated alterations remains unclear. This study aimed to characterize shoulder neuromuscular coordination patterns associated with aging and degenerative RCT using a multidimensional electromyographic approach. Surface electromyography was recorded from eight shoulder-related muscles during maximal shoulder abduction and flexion tasks in 106 participants, including young controls (YC, n=24), elderly controls (EC, n=24), and patients with degenerative RCT (n=58). Muscle synergy characteristics were quantified using non-negative matrix factorization (NMF). Intermuscular coordination was assessed using beta-band coherence analysis, and muscle interaction patterns were further evaluated using network topology metrics. Compared with YC participants, both EC and RCT groups demonstrated reduced muscle synergy dimensionality, with no significant differences between EC and RCT groups. Synergy structure analyses revealed task-dependent differences among groups, and RCT participants exhibited coordination patterns partially similar to those observed in elderly controls. Intermuscular coherence and network analyses demonstrated group-specific alterations mainly during shoulder abduction, involving deltoid-related and deltoid-scapular muscle interactions. These findings suggest that degenerative RCT is associated with altered muscle coordination patterns superimposed on age-related neuromuscular changes. This study provides a comprehensive characterization of age- and pathology-associated alterations in shoulder neuromuscular coordination. The integration of muscle synergy, coherence, and network analyses may provide quantitative insights into functional impairment mechanisms in degenerative RCT and support future development of individualized rehabilitation strategies.
-
6. Characterizing ECAP Detection Thresholds and Therapeutic Spinal Cord Stimulation Dose.
6. 表征ECAP检测阈值与治疗性脊髓刺激剂量PMID:期刊:日期:2026-09-25Evoked Compound Action Potentials (ECAPs) have been studied for their potential use as a feedback signal for paresthesia-based spinal cord stimulation (SCS) for chronic neuropathic pain. While paresthesia-based SCS therapy is still commonly used, paresthesia-free modalities have emerged over the past decade and are commonly preferred by patients because they avoid persistent stimulation-induced paresthesia. Characterizing the relationship between ECAP detection thresholds and both paresthesia-free and paresthesia-based SCS dosing may assist clinicians in selecting appropriate SCS systems and programming strategies for their patients. We characterized stimulation amplitudes for ECAP detection threshold, perception threshold, and discomfort threshold in patients undergoing a temporary SCS trial for chronic low back and/or leg pain as part of an exploratory clinical study. We found that ECAPs were not detected below most patients' perception threshold (PT) and were absent in all cases below 80% of PT. We also found that mean discomfort was reported across patients at $1.35\times $ the ECAP threshold (ET). This work characterizes the relationships between ECAP, perception, and discomfort thresholds for SCS and characterizes inter-patient and intra-patient variability, clarifying how electrophysiological signals and sensing system capabilities fit into the landscape of SCS therapies.
-
7. A Case Study Characterizing Healthy & Post-Stroke Neuromotor Behavior During 6D Upper-Limb Isometric Gaming: Implications for Design of End-Effector Rehabilitation Robot Interfaces.
7. 一项关于健康与卒中后神经运动行为在六维上肢等长收缩游戏中的特征研究:对末端执行器康复机器人界面设计的启示PMID:期刊:日期:2026-09-23Successful robot-mediated rehabilitation requires designing games and robot interventions that pro- mote healthy motor practice. However, the interplay between a given user's neuromotor behavior, the gaming interface, and the physical robot makes designing system elements - and even characterizing what behaviors are "healthy" or pathological - challenging. We leverage our OpenRobotRehab 1.0 open access data set to explore the characteristics of 13 healthy and 2 post-stroke users' force output, muscle activations, and game performance while executing isometric trajectory tracking tasks using an end-effector rehabilitation robot. We present an assessment of how subtle aspects of interface design impact user behavior; an exploratory analysis of how pathological neuromo- tor behaviors are reflected in end-effector force dynamics; and a novel hidden Markov model (HMM)-based neuro-motor behavior classification method based on surface electromyography (sEMG) signals during cyclic motions. We demonstrate that task specification (including which axes are constrained and how users interpret tracking instructions) shapes user behavior; that pathology-related features are detectable in 6D end-effector force data during isometric task execution, but that healthy neuromotor strategies are heterogeneous and inherently difficult to characterize; and that our HMM-based models discriminate healthy and post-stroke neuromotor dynamics where synergy-based decompositions reflect no such differentiation. Lastly, we discuss these results' implications for the design of adaptive end-effector rehabilitation robots capable of promoting healthier movement strategies across diverse user populations.
-
8. Close-Proximity Vision-Guided Control and Performance Evaluation of a Mobile Robot for Sit-to-Stand Assistance.
PMID:期刊:日期:2026-09-22A safe sit-to-stand (STS) transfer is an essential daily movement, but it can be difficult for older adults with reduced strength, balance, or coordination. Cost-effective STS assistance is therefore important for supporting independence. This paper presents a close-range, single RGB-D-camera solution for estimating pelvis motion and controlling a compact STS-assistive rollator. The robot provides two modes: a predefined fifth-order trajectory-following mode and a vision-adaptive mode that modulates the same nominal motion according to real-time pelvis-robot distance. In a feasibility study with healthy adults ( ${N}{=}{6}$ analyzed), both modes reduced lower-limb loading relative to unassisted STS. The predefined mode followed a fixed 3-second trajectory. This trajectory was selected based on our previous SkyWalker implementation and the healthy-adult STS timing literature, and it served as a baseline that provided larger and more consistent support. In contrast, the vision-adaptive mode synchronized the robot timing with the user's real-time pelvis motion, allowing users to stand at their preferred pace and resulting in lower handle loads and smaller compensatory trunk motion. These results suggest that the two modes may serve different assistance needs, with predefined support favoring stronger offloading and vision-adaptive support favoring user-paced interaction.
-
9. Epidural Fibrosis Raises Thresholds but Preserves Recruitment in Conventional Spinal Cord Stimulation: Lateral Steering Is Fragile.
9. 硬膜外纤维化会提高阈值,但在传统脊髓刺激中保留募集:侧向转向较脆弱PMID:期刊:日期:2026-09-22Epidural fibrosis (scar) around chronically implanted spinal cord stimulation (SCS) leads contributes to the late loss of efficacy known as the tolerance phenomenon, yet how maturing scar reshapes the intraspinal electric field, and which programming paradigms resist it, remain poorly understood. We combined a three-dimensional volume-conductor model of the thoracic spinal cord with multicompartment myelinated axon models and performed population-level uncertainty quantification across a virtual cohort (N = 200) varying in anatomy and scar properties. Four configurations-monopolar, longitudinal guarded tripole, transverse lateral-balance, and a guard-dominant steered tripole-were evaluated for threshold shift, spatial fidelity of activation, and recoverability. For monopolar and guarded tripole, the most common clinical programs, maturing scar behaved as a near-pure scalar attenuator, preserving the spatial activation pattern (median correlation > 0.99) so that amplitude re-titration restored the original modelled recruitment. Transverse lateral steering was the sole exception: failure was governed primarily by lead mediolateral offset. Near-centred leads were fragile (correlation 0.57; threshold rise +74%), whereas large offsets approached a less scar-sensitive quasi-monopolar drive (correlation 0.95; +7%). A guard-dominant configuration with limited lateral bias retained robustness even under asymmetric scar (correlation > 0.995). For most SCS programs, therefore, scar detunes amplitude rather than spatial target; lateral steering is intrinsically fragile under fibrosis, its reliability dictated by lead centring; and guard-dominant programming outperforms pure lateral balance when steering is required.
-
10. EMG Probability Density Function Inverse Problem: Motor Unit Potential Amplitude Versus Motor Unit Recruitment Threshold Maps.
10. 肌电概率密度函数逆问题:运动单位电位幅度与运动单位募集阈值映射关系PMID:期刊:日期:2026Solving the EMG probability density function inverse problem is a novel approach to extract motor unit information from single-channel EMG recordings. The method operates on EMG signals recorded during an isometric ramp contraction covering the entire muscle force range. The EMG is segmented into small portions, and each segment is characterized using the first two non-central sample moments. An iterative approach is employed to successively identify newly recruited motor units in each segment. At each step, an optimization algorithm estimates the set of motor unit potential (MUP) amplitudes that provide an EMG probability density function model yielding the best fit to the experimental moments. The algorithm is evaluated using simulated signals, showing its ability to provide accurate estimations of MUP amplitudes versus recruitment thresholds. The method is also applied to real signals recorded from the tibialis anterior in 61 healthy and 71 pathological subjects. Comparison between healthy and pathological groups provides evidence of muscle fiber reinnervation and motor unit remodeling. The resulting MUP amplitude versus recruitment threshold maps constitute an innovative and informative tool to assess muscle state.