TRANSFUSION输血
TRANSFUSION(英文缩写 TRANSFUSION),ISSN 0041-1132,eISSN 1537-2995,中文译名:输血 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 3.337 | Q3 |
| 2022 | 2.900 | Q3 |
| 2023 | 2.500 | Q2 |
| 2024 | 2.000 | Q3 |
| 2025 | 2.000 | Q3 |
TRANSFUSION 最新收录文献
-
1. Assessing the financial resources required to establish convalescent plasma collection programmes across Europe in response to a pandemic.
1. 评估欧洲各国为应对大流行病建立恢复期血浆采集项目所需的财政资源。PMID:日期:2026-10-01During the COVID-19 pandemic, convalescent plasma (CP) was investigated as a potential treatment. We assess the financial resources required to implement a COVID-19 CP (CCP) programme and provide recommendations on how best to prepare for collection and use of CP in future pandemics. We mapped pathways for collecting and manufacturing CCP using a UK blood establishment as a test case, and identified the resources required at each stage to provide high-titre (HT) CCP units. A top-down micro-costing approach and an economic model were used to establish the cost per HT CCP unit. Data collection questionnaires were later prepared to acquire data from 21 countries across Europe, facilitate comparisons and estimate costs per HT CCP unit using a top-down gross-costing approach. Costs are reported in Euros adjusted for cost-of-living differences. The key cost driver for England was the cost of CCP collection. Nine countries responded, four with existing infrastructure for apheresis plasma collection at the start of the pandemic and five without. Four countries provided sufficient data to estimate the cost per HT CCP unit, which varied between €198-€265 for countries with pre-existing apheresis plasma collection and €807-€1749 for those without. Countries had marked differences in the scale of CCP collection, and methods of selecting and measuring HT CCP, which contributed to the variation in expenditure observed. Costs were significantly lower in countries with existing infrastructure for apheresis plasma collection and where donors were tested for anti-SARS-CoV-2 antibody titre before attending plasma collection.
-
2. Co-design with community partners in blood donor recruitment: A global assessment.
PMID:日期:2026-09-30Blood services need to increase representativeness of donors from ethnically diverse communities, yet evidence-based recruitment strategies remain scarce. Co-design with community partners is a promising approach to developing culturally resonant materials, but the extent of its use globally remains unknown. We surveyed transfusion professionals registered with the Association for the Advancement of Blood and Biotherapies (AABB) and the International Society of Blood Transfusion (ISBT). Respondents reported recruitment methods in general use and ranked their perceived effectiveness. We then examined the adoption of co-design specifically for ethnically diverse donor recruitment, including attitudes, barriers, and evaluation. Of 170 respondents across four regions (Europe, North America, South-East-Asia, Rest-of-the-World), 94% reported that their institution actively recruited blood donors, and 51% identified they had a critical need for ethnically diverse supplies. Co-design was used by 33% of active recruiters, ranking seventh of 11 methods. Among those stating a critical need: 73% had developed ethnically tailored materials, 38% had used co-design, 13% co-designed videos, and 11% evaluated co-designed video effectiveness. Attitudes were favorable regardless of critical-need status, with 82%-89% endorsing bespoke videos as effective. Barriers were predominantly resource-based: funding (54%-57%), media-production expertise (29%-35%), and co-design expertise (24%-36%). Co-design for ethnically diverse donor recruitment is underused, revealing a belief-practice gap: attitudes are favorable, but adoption is low. Barriers are resource-based rather than attitudinal, and evaluation is rare. Wider adoption depends on building organizational capacity: funding, co-design expertise, and embedding evaluation from the outset.
-
3. Mapping obstetric biobanks: A scoping review highlighting gaps in the study of alloimmunized pregnancies.
PMID:日期:2026-09-29Maternal red cell alloimmunization can cause hemolytic disease of the fetus and newborn (HDFN), yet prediction of disease severity remains limited. Biobanks that link pregnancy biospecimens with clinical and laboratory data could accelerate translational research; however, the landscape of relevant obstetric biobanks has not been mapped. We conducted a scoping review following Joanna Briggs Institute methodology. MEDLINE, Embase, and CENTRAL were searched from January 2005 to May 20, 2025 for publications describing the establishment, structure, or operation of obstetric biobanks. Abstract screening, text review, and data extraction were conducted in duplicate. Findings were synthesized narratively. Of 2482 records screened, 29 publications met inclusion criteria, representing 21 unique biobanks across 18 countries and 6 continents. Most were conducted in high-income countries (n = 13) and were multicenter (n = 17). Biobanks primarily focused on environmental and genetic influences on development (n = 14) and pregnancy outcomes (n = 7), with no identified biobanks dedicated to alloimmunization. The types of maternal biospecimens collected varied, including whole blood (n = 19), plasma (n = 18), serum (n = 16), and urine (n = 16), with frequent collection of placental tissue (n = 14) and cord blood (n = 16). All biobanks incorporated maternal clinical variables (n = 21), whereas paternal (n = 10) and laboratory (n = 9) variables were less common. Only one biobank explicitly collected immunohematology variables (e.g., RhD status and maternal alloantibodies). Obstetric biobanks have the potential to accelerate discovery in alloimmunized pregnancies, but existing biobanks rarely capture immunohematologic variables. Integrating standardized immunohematology variables and paired maternal-fetal-paternal sampling into future initiatives could facilitate translational research on alloimmunization and HDFN.
-
4. Evaluation of an ABO antibody immunoadsorption column for reduction of anti-A and anti-B isoagglutinin titers in group O platelet units.
PMID:日期:2026-09-29Clinical guidelines recommend transfusing ABO-identical platelets where possible. However, the short shelf life of platelets (5-7 days) and stock availability mean ABO-nonidentical platelet transfusions are sometimes unavoidable. Minor ABO-incompatible platelet transfusions carry a risk of hemolysis due to donor anti-A/B antibodies, and high-titer (HT)-negative units are preferred to mitigate this risk. To further mitigate this risk, we investigated whether an ABO antibody immunoadsorption column could reduce anti-A/B titers in group O platelet units while preserving platelet quality. Six group O double dose apheresis platelet units were pooled with HT-positive group O plasma and split into three arms: untreated control, single-pass filtration (Glycosorb ABO A/B-column), and double-pass using the same column. Anti A and anti B IgM and IgG titers were measured pre- and post-filtration using a gel card method. Platelet count, platelet volume, coagulation factors, and markers of platelet quality and activation were assessed after filtration and during storage. Anti-A and anti-B titers were decreased from titers of 128 to ≤4 (IgM) and from 512 to ≤8 (IgG) following a single pass through the immunoadsorption column. Reduced efficacy was observed following a second pass through the same column (≤32 (IgM) and ≤128 (IgG)). Filtration was not associated with substantial platelet loss, although changes in some metabolic and activation markers were observed during storage. The ABO antibody immunoadsorption column effectively reduced anti-A/B titers in group O platelet units and may offer a strategy to increase the availability of low-titer platelets for transfusion.
-
5. A functionally distinct HPA-1a-specific alloantibody associated with fetal/neonatal alloimmune thrombocytopenia that activates platelets via FcγRIIa.
PMID:日期:2026-09-26Fetal/neonatal alloimmune thrombocytopenia (FNAIT) is caused by maternal alloantibodies directed against fetal platelet antigens, most commonly human platelet antigen-1a (HPA-1a). These antibodies mediate platelet destruction and can lead to fetal and neonatal thrombocytopenia severe enough to cause life-threatening organ bleeds. Antibody titer and isotype do not reliably predict disease severity, suggesting additional heterogeneity among anti-HPA-1a antibodies. We evaluated the effects of five previously characterized HPA-1a-specific monoclonal antibodies (mAbs) on platelet activation, platelet aggregation, and induction of intracellular signaling. The involvement of FcγRIIa was examined using FcγRIIa-blocking antibody IV.3, protein tyrosine kinase inhibitors, and selected monoclonal antibody Fab fragments. At saturating concentrations, all five mAbs inhibited thrombin-induced aggregation. At sub-saturating concentrations, however, mAb M-204 uniquely induced spontaneous aggregation and α-granule secretion in HPA-1a-positive human, but not mouse, platelets, which lack FcγRIIa. M-204-induced aggregation was abolished by mAb IV.3 and inhibitors of Src- and Syk-family kinases and was absent using M-204 Fab fragments. M-204 induced tyrosine phosphorylation of Syk and PLCγ2 in an FcγRIIa-dependent manner. Finally, despite persistent platelet activation induced by M-204, saturating concentrations of this antibody blocked the binding of the fibrinogen mimetic antibody, PAC-1, to HPA-1a homozygous, but not HPA-1a/1b heterozygous, platelets, consistent with the known ability of HPA-1a-specific antibodies to sterically interfere with ligand binding to HPA-1a-positive αIIbβ3. These findings identify a previously unrecognized, functionally distinct subset of HPA-1a antibodies capable of activating platelets via FcγRIIa, suggesting a potential mechanism contributing to variability in disease severity in FNAIT.
-
6. Prehospital whole blood transfusion versus component therapy-A scoping review.
PMID:日期:2026-09-26Whole blood has gained a foothold over component therapy in civilian emergency care, especially in emergency departments. In a prehospital setting, whole blood might be the logistically easier alternative compared to component therapy. However, most previous studies have been conducted in the emergency room setting. We performed a scoping review to explore what is known about the outcomes, safety and benefits of whole blood given prehospitally compared to component therapy in a primarily adult civilian population. We formed a systematic search strategy and conducted a literature search in several databases. The study selection was done according to predefined inclusion and exclusion criteria. Our primary endpoint was survival at 24 h. Secondary endpoints were also analyzed. The database search resulted in 1126 articles. After a systematic exclusion process, only six articles met the inclusion criteria. Whole blood usage was associated with similar mortality at 24 h and at other timepoints compared to component therapy. The analysis of secondary endpoints showed only minor or no differences between the groups. The differences in the outcomes of interest between patients receiving prehospital whole blood versus component therapy were minor and, in most cases, not statistically significant. The analysis of the different endpoints showed whole blood not to be inferior to component therapy. There is a growing evidentiary support for the use of whole blood in prehospital emergency care, but to make treatment recommendations in the future, more published evidence is needed.
-
7. Massive transfusion practices and low-titer group O whole blood utilization before and after implementation in a low-volume level I trauma center: A six-year review.
PMID:日期:2026-09-26Low-titer O whole blood (LTOWB) has been increasingly incorporated into trauma resuscitation and massive transfusion protocols (MTPs). Recent randomized trials have not demonstrated superiority of prehospital LTOWB over component-based resuscitation, while the utilization and sustainability of LTOWB programs, particularly in low-volume trauma systems, remain incompletely characterized. This was a 6-year review (April 2019-April 2025) of trauma MTPs at a level 1 trauma center with a low MTP frequency. Transfusion service logs, trauma flowsheets, prehospital and electronic medical records were reviewed for product usage, LTOWB utilization and discard patterns, and clinical outcomes. One hundred and twenty-five MTPs were identified (122 component-only and 11 LTOWB-supported), with predominantly male (70%) and 81% blunt trauma. Component MTPs had a median RBC utilization of 6 units; 45% required ≤1 MTP line. Prehospital LTOWB use was limited: 33% of units were transfused, and only 2 of 13 patients requiring an MTP received prehospital LTOWB. LTOWB-supported MTPs typically issued 10 units, and most patients received 1-2 units. Of 524 LTOWB units procured during the first 6 months, 201 were transfused and 323 discarded (62%), with a peak discard rate of 81% early in rollout. Overall, 30-day mortality was 54%, and 25% occurred within 4 h. LTOWB use was limited, and early wastage was substantial. LTOWB implementation in low-volume centers should align inventory and protocols with clinical demand; stewardship measures may reduce waste and improve sustainability.
-
8. Supported communication is a donor-safety intervention, not an eligibility exception.
PMID:日期:2026-09-26该文献暂无摘要。
-
9. From components to pharmaceuticals: A desirable evolution toward precision transfusion medicine.
PMID:日期:2026-09-26该文献暂无摘要。
-
10. {"_":"Novel missense variants in the RHAG gene that result in Rh phenotype.","sup":["mod"]}
PMID:日期:2026-09-25Identification of variants causing Rh deficiency phenotypes is important to allow safe transfusions and prevent hemolytic disease of the fetus and newborn. During preoperative screening for pseudomyxoma peritonei, a patient presented with suspicion of Rh-deficiency syndrome. The effect of these variants on the expression of Rh and Rh associated proteins was studied. Serotyping, MLPA genotyping, and next-generation sequencing were performed on the RBCs of the proband and their family members. The effect of the variants on membrane expression of RhAG, Rh proteins, as well as Rh complex membrane proteins was evaluated using flow cytometry and western blot. Transient transfection experiments were conducted to assay the consequences of the RhAG variants on RhAG, RhD, and RhCE membrane expression. Two novel missense variants in RHAG, RHAG:c.172C>T and RHAG:c.242G>A were identified resulting in an Rh phenotype. The novel RHAG variants decreased RhAG expression with a concomitant reduction in expression of Rh proteins and CD47 while a slight increase in band3 expression was observed in the proband. A reduction of CD44 expression was also observed. Transfection of c.172C>T did not lead to a lower RhAG expression, while in contrast, expression of c.242G>A was significantly decreased compared to RhAGwt. Both led to a reduction of RhD and RhCE expression. Co-transfection of RHAGwt with c.172C>T or c.242G>A led to a significant reduction in RhD and RhCE expression. Two novel RHAG variants leading to Rh phenotype were identified. A decrease in CD44 expression not previously associated with this phenotype was observed.