Journal of Electrocardiology心电图学杂志
Journal of Electrocardiology(英文缩写 J ELECTROCARDIOL),ISSN 0022-0736,eISSN 1532-8430,中文译名:心电图学杂志 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 1.380 | Q4 |
| 2022 | 1.300 | Q4 |
| 2023 | 1.300 | Q3 |
| 2024 | 1.200 | Q4 |
| 2025 | 1.500 | Q3 |
Journal of Electrocardiology 最新收录文献
-
1. Transient changes in P-wave terminal force after electrical cardioversion of persistent atrial fibrillation.
PMID:日期:2026-09-28P-wave terminal force in lead V1 (PWTFV1) reflects left atrial remodeling and is associated with atrial fibrillation (AF) outcomes, but its time course after electrical cardioversion of persistent AF is unclear. We retrospectively analyzed 108 patients with persistent AF after successful electrical cardioversion, with 12‑lead electrocardiograms at 30 min, 1 month, and 3 months. Terminal P-wave duration (PNTV1) and amplitude (PNAV1) in lead V1 were measured and PWTFV1 calculated as their product; changes are expressed in absolute magnitude. Correlations with left atrial diameter and categorical classification (abnormal if magnitude ≥4000 ms·μV) were assessed. PNTV1 increased at 1 month versus 30 min (60 ± 25 vs 58 ± 19 ms; P = 0.018) and returned to baseline at 3 months (57 ± 19 ms; P = 0.83; Friedman P = 0.031). PNAV1 was unchanged (P = 0.37). PWTFV1 increased transiently in magnitude at 1 month (-4294 ± 2545 vs -4079 ± 2138 ms·μV; P = 0.022) and normalized at 3 months (-4039 ± 2060 ms·μV; P = 0.64). PWTFV1 did not correlate with left atrial diameter (all |ρ| ≈ 0.05, P ≥ 0.61), and categorical classification was unchanged (57/108 abnormal throughout; no patient reclassified). PWTFV1 shows transient, duration-driven variability after cardioversion, peaking at 1 month. The change is small, does not alter categorical classification, and is not mirrored by left atrial size, consistent with ongoing atrial recovery rather than stable remodeling. Timing of assessment matters when PWTFV1 is interpreted as a continuous measure.
-
2. Beat-to-beat signatures of sleep apnea across cardiovascular diseases.
PMID:日期:2026-09-25Obstructive sleep apnea (OSA) is closely linked with cardiovascular disease (CVD), but different cardiovascular phenotypes may influence ECG-derived RR interval dynamics differently. Previous work has shown that scale-dependent detrended fluctuation analysis (sDFA) can detect OSA across broad CVD status, but it remains unclear whether this relationship differs between CVD subtypes. Overnight polysomnography recordings from the Sleep Heart Health Study were analyzed in participants with a history of myocardial infarction (MI), congestive heart failure (CHF), or angina pectoris (ANG). Participants with more than one of these conditions were excluded. OSA was analyzed as a binary outcome using an apnea-hypopnea index threshold of 5 events/h. Propensity score matching was performed within each subgroup using age and body mass index. ECG-derived RR interval dynamics were analyzed using cHRV metrics and second-order sDFA, with discrimination assessed using ROC-AUC. The matched subgroups consisted of 112 participants with MI, 18 with CHF, and 54 with ANG. sDFA achieved higher ROC-AUC values than cHRV metrics in all subgroups. The highest sDFA ROC-AUC was observed in ANG (0.79), compared with 0.66 in MI and 0.69 in CHF. MI and ANG showed broadly similar scale-dependent profiles, whereas CHF appeared distinct; however, the CHF analysis was substantially underpowered. ECG-derived sDFA features showed subtype-dependent behavior for OSA discrimination, with the strongest performance observed in ANG. These exploratory findings suggest that cardiovascular phenotype may influence OSA-related RR interval dynamics. Binary OSA grouping may mask severity-related differences, while exclusion of participants with multiple cardiovascular conditions limits clinical applicability.
-
3. Atrioventricular block and optimal synchronous pacing on ECG in a single lead VDD pacing population.
PMID:日期:2026-09-24In patients with atrioventricular (AV) block and preserved sinus node function on 12‑leads electrocardiogram (ECG) a single‑lead VDD pacing is today an established alternative to dual-chamber pacing, potentially offering reduced complications. Optimal pacing in AV block should maintain the AV synchrony on ECG in order to maximize cardiac output as well as stroke volume. Therefore in single‑lead VDD pacing population a proper planning of the AV interval is critical, as it allows the atrial contraction to complete before ventricular activation begins. We enrolled 67 consecutive patients with complete AV block and preserved sinus node function, with a single‑lead VDD pacemaker indication. According to atrial dipole length patients were divided into a long-dipole group (>20 mm, n = 25) and a short-dipole group (≤20 mm, n = 26), while 16 patients were excluded (8 due to loss at follow-up, 8 for clinical non-eligibility considering atrial fibrillation and/or documented sinus node dysfunction). The mean atrial sensing amplitude was 0.60 ± 0.56 mV in the long-dipole group versus 1.16 ± 0.92 mV in the short-dipole group (p = 0.02) at 6-months follow-up. AV synchrony was significantly higher with long dipoles (95.4 ± 4.6%) compared with short dipoles (84.6 ± 25.5%; p = 0.04) at same follow-up. In a single‑lead VDD pacing population, a longer atrial dipole is associated with a superior AV synchrony on ECG despite lower atrial sensing, supporting the concept that detection stability and electro-geometric consistency may prevail over absolute signal amplitude in preserving AV synchrony.
-
4. Association of pre-transplant electrocardiogram with long-term cardiovascular events in liver transplant recipients.
4. 移植前心电图与肝移植受者长期心血管事件的关联PMID:日期:2026-09-23Cardiovascular disease accounts for approximately 20% of deaths among post-liver transplant (LT) patients. Although electrocardiograms (ECGs) are commonly included in pre-transplant evaluations, their association with long-term major adverse cardiovascular events (MACE) has not been well studied. We retrospectively studied 298 patients who underwent LT at a tertiary academic center, 2014-2024. Pre-LT ECGs were reviewed by trained readers blinded to clinical outcomes. The primary outcome was MACE (cardiovascular death, myocardial infarction, coronary revascularization, hospitalization for unstable angina, heart failure hospitalization, ischemic stroke, or arrhythmia requiring hospitalization). Among 298 patients, 63 (21.1%) experienced MACE over a median follow-up of 4.6 years (IQR 2.3-7.2). Anterior T-wave inversion (TWI) (n = 26, 8.7%) showed the strongest association in exploratory lead-distribution analysis; inferior and lateral TWI were not. After adjustment for age, diabetes, atrial fibrillation, and coronary artery disease (CAD), anterior TWI remained independently associated with MACE (adjusted HR 2.17; 95% CI 1.07-4.41) and was modified by CAD status (interaction p = 0.017): among patients without known CAD the adjusted HR was 5.11 (95% CI 2.18-11.97). Excess risk was confined to heart failure (cause-specific HR 3.98; 95% CI 1.51-10.49). Adding anterior TWI did not improve discrimination (3-year AUC 0.765 vs 0.727). In this single-center study, anterior TWI on pre-transplant ECG was independently associated with an increased risk of MACE after LT, an association concentrated among candidates without known CAD and driven by heart failure. Because the lead-distribution comparison was exploratory and anterior TWI did not improve model discrimination, external validation is required before it is adopted for formal risk stratification.
-
5. Double transition in ventricular preexcitation.
5. 心室预激中的双径路转变现象PMID:日期:2026-09-19In the Wolff-Parkinson-White syndrome, numerous electrocardiographic (ECG) algorithms have been developed for the prediction of accessory pathway (AP) location. In addition to such algorithms, recognizing simple, unique and eye-catching ECG patterns that are specific for particular AP positions can provide further visual aid in quickly predicting the likely effective ablation site. Recently, such a distinctive ECG configuration has been introduced that showed high specificity for right posteroseptal (right paraseptal) APs. The "double transition" sign was characterized by showing more positive QRS complexes in lead V2 than in either of its neighboring leads V1 and V3. In some cases, the entire QRS complex was downgoing in V1 and V3, but upgoing in V2. In the double transition study, no explanation was provided as to the cause of this curious phenomenon, and why it had high specificity but low sensitivity for right posteroseptal APs. In this report we present our experience with the double transition sign, expand on its electrocardiographic spectrum, and offer a simple and rational explanation for the probable cause of this seemingly strange and perplexing phenomenon.
-
6. 12-lead electrocardiography-based scoringsystem for predicting the probability of atrial septal defect closure in adults with pulmonary hypertension.
PMID:日期:2026-09-17Assessing atrial septal defect (ASD) operability in patients with pulmonary hypertension (PH) is challenging in resource-limited settings due to restricted access to right heart catheterization (RHC). This study aims to develop and validate a 12‑lead electrocardiography (ECG)-based scoring system to predict ASD closure feasibility. We conducted a cross-sectional study using ECG data from adult patients with isolated ASD in the COHARD-PH Registry. ASD was confirmed by echocardiography, and PH was diagnosed by RHC. Based on hemodynamic criteria, patients were classified as closure or non-closure. The Spiegelhalter Knill-Jones approach was used for model development, and the receiver operating characteristic (ROC) curve analysis assessed accuracy. Among 199 ASD patients, 58.7% had PH, and 76% had a pulmonary vascular resistance index (PVRI) >8 WU. Six ECG criteria were identified as predictors of ASD closure feasibility: (1) P amplitude in lead II ≥ 2.5 mm, (2) R in V1 > 6 mm, (3) ∑ (R in V1+ S in V5 or V6) > 10.5 mm, (4) QR pattern in V1, (5) negative T waves in V1-V3, and (6) S in V5 > 10 mm. Patients scoring -18 to -9 had a 98% probability of ASD closure, while those scoring 9 to 17 had only a 6% probability. The scoring system demonstrated an AUC of 0.911, with a sensitivity of 95.5% and specificity of 77.3%. We developed a 12‑lead ECG-based scoring system that provides a practical and accessible method for identifying candidates for referral, particularly in resource-limited settings. Further validation in diverse populations is needed to enhance its clinical applicability.
-
7. What does QTc actually predict in non-ischemic heart failure?
7. QTc在非缺血性心力衰竭中究竟能预测什么?PMID:日期:2026-09-17该文献暂无摘要。
-
8. Why blinding sex is not enough: equitable discrimination, unequal operation in machine-learning detection of myocardial infarction from the ECG.
8. 为何盲法性别不够:心电图机器学习检测心肌梗死中的公平辨别与不等效操作PMID:日期:2026-09-16Automated electrocardiogram (ECG) interpretation is proposed to standardise myocardial infarction (MI) detection, but whether such models reproduce under-diagnosis of MI in women is unclear. Sex- and age-related equity in MI-versus-normal detection was audited on PTB-XL as a benchmark classification audit (14,437 ECGs, 12,940 patients; MI-labelled record proportion 0.296 in women, 0.455 in men), across four models sharing a patient-grouped, hash-frozen 70/15/15 split: interpretable gradient-boosted trees with and without sex and age, and a raw-signal convolutional network under two normalisation schemes. Discrimination was separated from the operating point; bootstrap intervals were resampled by patient. Discrimination by sex and by age showed no statistically detectable between-sex difference in any model (area under the ROC curve, AUC, 0.96 to 0.98; DeLong non-significant), and no male-minus-female contrast in calibration intercept or slope survived correction. At the default 0.5 threshold recall was lower in women, the disparity declined continuously with age in exploratory analysis, reaching 0.176 and 0.240 below 60 years. Female median scores were lower than male ones within both true classes (Holm-adjusted p 0.002 to 0.038), a calibrated shift tracking the smaller female class proportion. Amplitude features predicted sex collectively (AUC 0.845). Sex-specific thresholding narrowed the gap but gave no stable younger-female cut. Discrimination and calibration showed no detectable between-sex difference, yet the 0.5 threshold produced lower recall in women, most markedly in younger women, a descriptive and exploratory finding tied to the operating point. Fairness is best verified per subgroup and in external validation.
-
9. Electrocardiographic identification of Para-Hisian right ventricular pacing predicts response to cardiac resynchronization therapy.
9. 心电图识别希氏束旁右心室起搏可预测心脏再同步化治疗的反应PMID:日期:2026-09-15Cardiac resynchronization therapy (CRT) improves outcomes in patients with heart failure and electrical dyssynchrony; however, electrocardiographic markers identifying a favorable right ventricular (RV) pacing configuration have not been well established. To evaluate whether an electrocardiography (ECG)-defined classification of RV pacing is associated with electrical and echocardiographic response to CRT. We retrospectively studied 33 consecutive patients who underwent CRT-pacing. RV pacing configuration was classified using predefined ECG criteria consisting of an R wave in lead I, a lead III/II R-wave ratio < 1 or inferior lead discordance, positive polarity in lead aVL, and absence of His bundle capture. Patients fulfilling all criteria were classified as the ECG-defined para-Hisian pacing (PHP) group (n = 7), and the remaining patients comprised the non-PHP group (n = 26). Electrocardiographic and echocardiographic parameters were compared at baseline and after 6 months of follow-up. At 6 months, patients in the PHP group demonstrated significantly narrower QRS duration than those in the non-PHP group (123.4 ± 11.4 ms vs. 151.9 ± 20.2 ms, P < 0.01). The PHP group also exhibited greater reductions in left ventricular end-systolic volume (-34.8 ± 13.1% vs. -3.3 ± 31.3%, P < 0.05) and greater improvement in left ventricular ejection fraction (12.6 ± 8.7% vs. 4.0 ± 10.2%, P < 0.05). Heart failure hospitalization rates were similar between groups. An ECG-defined para-Hisian RV pacing configuration was associated with greater electrical resynchronization and improved left ventricular reverse remodeling following CRT. These findings suggest that ECG characteristics of RV pacing may help identify a favorable pacing configuration and warrant validation in larger prospective studies.
-
10. Beyond signal alignment-Addressing unresolved factors in synthesized posterior ECGs.
10. 超越信号对齐——解决合成后位心电图中的未解因素PMID:日期:2026-09-14该文献暂无摘要。