ULTRASCHALL IN DER MEDIZIN超声医学
ULTRASCHALL IN DER MEDIZIN(英文缩写 ULTRASCHALL MED),ISSN 0172-4614,eISSN 1438-8782,中文译名:超声医学 是一本学术期刊。本页汇总该期刊的最新影响因子、分区信息以及最新收录于 PubMed 的文献,帮助您快速了解期刊全貌。
发文量统计区间:2025-11-01 至 2026-10-31,按本站收录文献的发表日期统计。
期刊介绍
历年影响因子趋势
| JCR 数据年份 | 影响因子 | JCR 分区 |
|---|---|---|
| 2021 | 5.445 | Q1 |
| 2022 | 3.400 | Q1 |
| 2023 | 3.100 | Q1 |
| 2024 | 2.900 | Q1 |
| 2025 | 3.200 | Q1 |
ULTRASCHALL IN DER MEDIZIN 最新收录文献
-
1. Response to the Letter to Editor (The Role of Ultrasound in Gynecomastia).
PMID:日期:2026-10-01该文献暂无摘要。
-
3. Digital Vaginal and Ultrasound Assessments and the Likelihood of Intrapartum Cesarean Delivery: A Prognostic Factor Study.
3. 数字阴道检查与超声评估及分娩期剖宫产的可能性:一项预后因素研究PMID:日期:2026-09-29PURPOSE: Ultrasound offers an objective method of assessing the progress of labor. We sought to examine whether repeat clinical and ultrasound assessments during labor were prognostic of the mode of delivery. MATERIALS AND METHODS: Term nulliparous women underwent ultrasound assessment of fetal head position, head descent measured as head-perineum distance, caput succedaneum, molding, umbilical, and middle cerebral artery Doppler, as well as assessment of cervical dilatation by digital vaginal examination. Univariable and multivariable logistic regression analyses were used to investigate a prognostic model for intrapartum cesarean delivery. RESULTS: Of 270 participants, 269 were able to be evaluated. Two hundred nineteen (81%) had repeat ultrasound and clinical assessments; intrapartum cesarean delivery was required in 79 (29%). The most important parameters to determine the likelihood of intrapartum cesarean delivery from the initial assessment were head station (adjusted odds ratio [AOR] 1.08 per mm, 95% CI 1.04-1.13, < 0.0001) and cervical dilatation (AOR, 0.78 per cm, (95% CI 0.66-0.92, = 0.0025). For repeat assessments, change in cervical dilatation per hour was the most important (AOR, 0.10 per cm, [95% CI 0.03-0.26, < 0.0001]). Multivariable analysis of the initial assessment including gestational age, head descent, cervical dilatation, and caput succedaneum gave an area under the curve of 0.72 and 0.78 when cervical dilatation and caput succedaneum were included. CONCLUSION: This study identifies the key parameters associated with mode of delivery during labor. Clinical assessment of cervical dilatation and ultrasound measurement of head station at the initial assessment are the most promising prognostic parameters for intrapartum cesarean delivery. Repeat assessment including change in cervical dilatation improved the prediction to a level that is potentially clinically useful.
-
4. Device-Specific Cut-Offs of Canon Aplio i800 2D Shear Wave Elastography for Advanced Fibrosis in MASLD: A Histologically Validated Study.
PMID:日期:2026-09-21To evaluate the diagnostic accuracy of Canon Aplio i800 two-dimensional shear wave elastography (2D-SWE) for detecting advanced fibrosis (≥ F3) in metabolically associated steatotic liver disease (MASLD) using histology as reference, and to compare its performance with the FIB-4 index. In this prospective single-center study, 49 patients with MASLD and available liver histology were included. Fibrosis staging (F0-F4) was assessed by three blinded pathologists according to Brown and Kleiner. Shear wave velocity (m/s) served as the primary elastography parameter. Diagnostic performance for ≥ F3 was assessed by ROC analysis, and clinically applicable rule-in and rule-out thresholds were determined using predefined sensitivity- and specificity-based criteria. Advanced fibrosis (≥ F3) was present in 15/49 patients (30.6%). 2D-SWE demonstrated an AUROC of 0.88 (95% CI 0.78-0.96) for ≥ F3, compared with 0.84 (95% CI 0.71-0.96) for FIB-4 (p = 0.39). A threshold of 1.45 m/s (6.3 kPa) achieved 100% sensitivity and negative predictive value. A threshold of 1.85 m/s (11.0 kPa) yielded 94% specificity and 82% positive predictive value. Canon Aplio i800 2D-SWE provides robust and clinically applicable, device-specific non-invasive detection of advanced fibrosis in MASLD and supports implementation into guideline-based stepwise risk stratification.
-
5. Clinical and ultrasound characteristics of uterine perivascular epithelioid cell tumors.
PMID:日期:2026-09-10To describe the ultrasound characteristics of uterine perivascular epithelioid cell tumors (PEComas). This retrospective multicenter case series included patients from two Italian academic centers specializing in oncological care. All women with histologically confirmed uterine PEComas between January 2013 and December 2024 and available clinical and ultrasound data were included. Ultrasound images were reviewed by three expert sonographers using Morphological Uterus Sonographic Assessment (MUSA) terminology. Thirteen patients were identified, including 8 malignant and 5 benign PEComas. The median age was 54 years (IQR 46-65). Six patients (46%) were asymptomatic, five (38%) presented with abnormal uterine bleeding, one (8%) with pelvic pain, and one (8%) with abdominal bloating. Tumors originated from the cervix (38%), uterine corpus (46%), and isthmus (15%). On transvaginal ultrasound, most PEComas appeared as solitary, round, solid masses with regular margins (62%) and inhomogeneous echogenicity (69%), with a median diameter of 42 mm (IQR 23-66). Irregular cystic areas were observed in six cases (46%), while shadowing and hyperechoic islands were absent. Power Doppler assessment revealed moderate to rich vascularization (color score 3-4) in 9 cases (69%). Malignancy was suspected on initial ultrasound in only 4 cases (31%). Uterine PEComas commonly present as solitary, solid, round masses with regular margins, inhomogeneous echogenicity, and marked vascularization. Typical features such as shadowing or hyperechoic islands are absent. Despite these characteristics, malignancy is often underrecognized on initial ultrasound.
-
6. Contrast-enhanced super-resolution imaging of the liver.
PMID:日期:2026-09-09The present review of the most common liver lesions describes the possibilities for using the novel super-resolution contrast-enhanced ultrasound technique. There are advantages for visualizing the microvasculature and thus for the characterization of a vascular pattern: in the arterial phase as benign and regular or as malignant and irregular. In the case of hepatocellular carcinomas, small irregular focal lesions or signs of remaining tumor or early tumor recurrence after partial tumor resection or ablation can be identified. Benign tumors usually have a regular vascular pattern. Especially in the case of focal nodular hyperplasia (FNH), the regular vascular pattern can be clearly visualized on super-resolution imaging. In the case of malignant lesions, the technique can show the irregular neovascularization. The case studies relate to the most common liver lesion entities that can be detected and characterized in large clinical studies with high diagnostic certainty with dynamic contrast-enhanced ultrasound (CEUS).
-
7. The Core Compendium of the European Society for Emergency Medicine Ultrasound Curriculum.
PMID:日期:2026-09-08The diversity of healthcare systems across Europe has predictably resulted in significant variations in point-of-care ultrasound (PoCUS) training and practice for emergency medicine (EM). To encourage a more synchronized approach and address these inconsistencies, the European Society for Emergency Medicine (EUSEM) chartered its Ultrasound Section to develop a comprehensive curriculum compendium that should serve as a foundational guide for European Emergency Medicine PoCUS clinical and educational guidelines and policies. Under the leadership of a dedicated task force, the EUSEM Ultrasound Section developed this compendium to provide a structured, tiered framework designed to meet the needs of physicians at every skill level, from novice to advanced users. The compendium emphasizes applications that are currently practiced in different and diverse emergency departments in Europe, including a broad range of topics. An important goal was allowing flexibility to accommodate the unique resources and challenges of different healthcare environments, so that EM physicians can achieve PoCUS competencies matching their local circumstances and needs. To achieve this goal, good educational and clinical stewardship throughout this process is a key part to the success of advancing PoCUS in European EM. This compendium is intended as a resource for creating standardized yet adaptable training pathways. It represents a major step toward harmonizing and advancing PoCUS practice in European EM.
-
8. Assessing focal liver lesions in Beckwith-Wiedemann Syndrome: Comparison of contrast-enhanced ultrasound and magnetic resonance imaging.
8. 评估Beckwith-Wiedemann综合征中的局灶性肝脏病变:对比增强超声与磁共振成像的比较PMID:日期:2026-09-01Beckwith-Wiedemann Syndrome (BWS) predisposes children to hepatoblastoma and other cancers and requires tumor screening with abdominal ultrasound and magnetic resonance imaging (MRI) when lesions are seen. Contrast-enhanced ultrasound (CEUS) may offer an alternative to MRI, which often requires sedation. Our aim was to evaluate the diagnostic performance of CEUS compared to MRI in this group when evaluating liver lesions, to compare sedation requirements, and to assess imaging features correlated with malignancy. This was a retrospective review of patients with molecular BWS and liver lesions who underwent MRI and CEUS within 6 months. Demographics, sedation requirement, and final diagnosis (pathology or follow-up imaging) were recorded. Two blinded radiologists per category classified lesions (benign/malignant/indeterminate) and detailed imaging features. Test performance and inter-rater reliability (Cohen's κ) were calculated. 12 patients (7 females, mean age 3 months) were included. A final diagnosis of 3 hepatoblastomas and 9 benign lesions was derived from pathology in 4 cases and from imaging follow-up in 8. Ten MRI examinations (83%) and no CEUS examinations required sedation. On consensus read, CEUS had a sensitivity of 67% and a specificity of 89%; κ = 0.70. MRI had a sensitivity of 75% and a specificity of 100%; κ = 0.25. Iso-enhancement and washout on CEUS and cystic change, necrosis, and diffusion restriction on MRI correlated with malignancy. Our findings suggest that CEUS has good diagnostic accuracy and high inter-rater reliability and allows sedation avoidance, suggesting that its use could allow MRI to be reserved for indeterminate or malignant lesions.
-
9. Prenatally diagnosed Ebstein's anomaly and tricuspid valve dysplasia: associated anomalies and predictors of outcome in a multicenter cohort study.
PMID:日期:2026-08-19To describe associated anomalies and outcomes of prenatally diagnosed Ebstein's anomaly (EA)/tricuspid valve dysplasia (TVD) in a multicenter cohort and to identify predictors of adverse outcome (intrauterine or postnatal death). In this retrospective study, cardiothoracic ratio, aortic valve diameter (AVD), pulmonary and atrioventricular valve measurements, ventricular dimensions, vena contracta, chamber areas, Celemajer index, peak tricuspid regurgitation velocity (TR_max), and pulmonary flow direction between survivors and non-survivors were compared across three gestational intervals. Among 87 fetuses, 7 (8.0%) intrauterine deaths and 7 (8.0%) terminations occurred; 14 (16.1%) were lost to follow-up. Fifty-nine (67.8%) live births with follow-up were documented; 52 (88.1%) underwent active postnatal management, with a survival rate of 69.2% (36/52). Non-survivors more frequently had hydrops, earlier delivery, and lower birth weight. z-score AVD (zAVD) was lower and pulmonary flow more often retrograde in non-survivors before 32 weeks. TR_max was lower in interval 1 (<24 weeks), and right atrial area and vena contracta were larger in interval 2 (24-32 weeks). No significant differences were observed after 32 weeks. This is one of the largest prenatal multicenter cohorts employing a longitudinal design, with echocardiographic data evaluation across three gestational intervals. Established predictors (pulmonary flow, TR_max) were confirmed and zAVD was identified as a simple, clinically applicable parameter, highlighting the relevance of left ventricular involvement in EA/TVD. Zusammenfassung: Ziel: Ziel dieser retrospektiven, multizentrischen Studie war es, assoziierte Anomalien und das Outcome bei pränatal diagnostizierter Ebstein-Anomalie /Trikuspidalklappendysplasie (EA/TVD) zu analysieren sowie Prädiktoren für ein ungünstiges Outcome (intrauteriner Fruchttod (IUFT), postnataler Tod) zu identifizieren. Retrospektiv wurden kardiothorakale Ratio, Aortenklappendurchmesser (AVD), pulmonale und atrioventrikuläre Klappen, Ventrikeldimensionen, Vena contracta, Vorhof-/Ventrikelflächen, Celemajer-Index, maximale Trikuspidalinsuffizienzgeschwindigkeit (TR_max) und Pulmonalflussrichtung zwischen Überlebenden und Nicht-Überlebenden in drei3 Gestationsintervallen verglichen. Ergebnisse: Von 87 Feten traten 7 (8,0%) IUFT auf, 7 (8,0%) Schwangerschaftsabbrüche erfolgten, 14 (16,1%) waren lost to follow-up. Insgesamt wurden 59/87 (67,8%) Lebendgeburten dokumentiert; 52 (88,1%) erhielten ein aktives postnatales Management mit einer Überlebensrate von 69,2% (36/52). Nicht-Überlebende zeigten häufiger Hydrops, frühere Entbindung und geringeres Geburtsgewicht. Der Z-Score des AVD (zAVD) war <32 Wochen niedriger, der Pulmonalfluss häufiger retrograd. TR_max war <24 Wochen niedriger, rechte Vorhoffläche und Vena contracta zwischen 24-32 Wochen größer. Nach 32 Wochen bestanden keine signifikanten Unterschiede. Schlussfolgerung: : Dies ist eine der größten pränatalen, multizentrischen Kohorten mit longitudinaler Auswertung über drei3 Gestationsintervalle. Etablierte Prädiktoren (Pulmonalfluss, TR_max) wurden bestätigt, und zAVD als einfacher, klinisch anwendbarer Parameter identifiziert, der die Relevanz der linksventrikulären Beteiligung bei EA/TVD unterstreicht.
-
10. Contrast-Enhanced Ultrasound Versus Contrast-Enhanced Computed Tomography in the Detection of Renal and Splenic Infarctions.
10. 对比增强超声与对比增强计算机断层扫描在检测肾和脾梗死方面的比较PMID:日期:2026-08-17[中文摘要] 腹腔内脏器梗死需要及时影像学检查以明确诊断。对比增强计算机断层扫描(CECT)被视为金标准,但涉及辐射、碘对比剂,且在危重患者中操作存在实际困难。对比增强超声(CEUS)能够实时评估微血管灌注,且无电离辐射。本研究旨在评估CEUS与CECT相比检测腹腔内脏器梗死的诊断效能。本回顾性观察研究纳入2010年至2024年在一家三级医疗中心接受治疗、因疑似腹腔内脏器梗死而同时接受CEUS和CECT检查的患者。以CECT为参考标准,计算诊断效能参数及一致性(Cohen's kappa)。共纳入24例患者(中位年龄60岁;女性12例)。CECT确认16/24例患者(66.7%)存在器官梗死。CEUS正确识别其中15例(敏感性93.8%;95%置信区间[CI]:71.7-98.9%)。特异性为75.0%(95% CI:40.9-92.9%),有2例CEUS假阳性结果。阳性和阴性预测值分别为88.2%(95% CI:65.7-96.7%)和85.7%(95% CI:48.7-97.4%)。CECT与CEUS的一致性为高度一致(Cohen's κ = 0.71)。在CT确认的梗死中,两种检查方法均发现93.8%存在楔形灌注缺损。CEUS在检测腹腔内脏器梗死方面表现出高敏感性,并与CECT具有良好一致性。CEUS是一种有价值的影像学方法,尤其在CECT禁忌或不可用时。有必要开展前瞻性研究以进一步明确其在临床实践中的作用。
[英文摘要] Intra-abdominal organ infarctions require prompt imaging for diagnosis. Contrast-enhanced computed tomography (CECT) is considered the gold standard but involves radiation, iodinated contrast, and logistical challenges in critically ill patients. Contrast-enhanced ultrasound (CEUS) enables real-time assessment of microvascular perfusion without ionizing radiation. The aim of this study was to evaluate the diagnostic performance of CEUS compared to CECT for detecting intra-abdominal organ infarctions. This retrospective observational study included patients treated at a tertiary care center (2010-2024) who underwent both CEUS and CECT for suspected intra-abdominal organ infarction. With CECT as reference standard, diagnostic performance parameters and agreement (Cohen's kappa) were calculated. 24 patients (median age 60 years; 12 female) were included. CECT confirmed organ infarction in 16/24 patients (66.7%). CEUS correctly identified 15 of these cases (Sensitivity 93.8%; 95% confidence interval [CI]: 71.7-98.9%). Specificity was 75.0% (95% CI: 40.9-92.9%), with two false-positive CEUS findings. Positive and negative predictive values were 88.2% (95% CI: 65.7-96.7%) and 85.7% (95% CI: 48.7-97.4%), respectively. Agreement of CECT and CEUS was substantial (Cohen's κ = 0.71). Wedge-shaped perfusion defects were identified in 93.8% of CT-confirmed infarctions on both modalities. CEUS demonstrates high sensitivity and good agreement with CECT for the detection of intra-abdominal organ infarctions. CEUS represents a valuable imaging modality, particularly when CECT is contraindicated or not available. Prospective studies are warranted to further define its role in clinical practice.