REVIEW OF SCIENTIFIC INSTRUMENTS 最新收录文献
-
1. Generalized theory of second-harmonic orthogonally polarized dispersion interferometry and implementation for pulsed power electrode plasma measurements.
1. 二次谐波正交偏振色散干涉测量法的广义理论及其在脉冲功率电极等离子体测量中的实现PMID:日期:2026-10-01We present a generalized theoretical framework for Second-Harmonic Orthogonally Polarized Dispersion Interferometry (SHOP-DI) and the diagnostic's implementation for time-resolved electron areal-density measurements of pulsed-power Magnetically Insulated Transmission Line (MITL) electrode plasmas. The theoretical treatment extends standard SHOP-DI analysis by deriving the detected intensity response for arbitrary second-harmonic polarization angles, establishing a detector-bandwidth-limited criterion for the maximum trackable rate of change in electron areal density, modeling a counter-rotating phase-control-window system that enables reproducible phase-offset calibration, and introducing a power-normalized analysis method which separates refractive-index-induced phase shifts from static channel imbalance and common-mode optical-power fluctuations. Guided by these developments, the diagnostic was redesigned for operation on Sandia National Laboratories' (SNL's) 1 MA Mykonos accelerator, where MITL plasmas evolve on nanosecond time scales within sub-mm Anode-Cathode (A-K) gaps. The implemented system combines a 2 GHz bandwidth, corresponding to a maximum measurable areal-density rate of change of 4.8 × 1016 1/cm2/ns, with an overlapping 1/e2 probing beam waist diameter of ∼100μm. Improved optical throughput and optomechanical stiffness enabled the experiments at Mykonos to achieve a noise-limited 1σ areal-density uncertainty of 1.6 × 1014 1/cm2. These results provide design criteria for future SHOP-DI systems and demonstrate a high-bandwidth, high-sensitivity design useful for pulsed-power electrode plasma measurements.
-
2. Piston-cylinder apparatus with a working volume of 22 cm3 and pressure up to 23 kbar for ultra-high-pressure synthesis in the liquid phase.
2. 工作体积为22立方厘米、压力可达23千巴的活塞-圆筒装置,用于液相超高压合成PMID:日期:2026-10-01In this paper, we provide a detailed description of a liquid-phase high-pressure apparatus with a working volume of 22 cm3 and a maximum pressure capacity of 23 kbar and temperatures up to 150 °C. Alongside the design of the ultra-high-pressure reactor, we also outline the structure of the three-layer steel reaction chamber. This apparatus was specifically developed for organic synthesis in the liquid phase and allows precise control of pressure and temperature-critical factors for optimizing reaction conditions. A key engineering achievement of this apparatus is its ability to facilitate reactions with standard solvents (such as methanol and dichloromethane) across a pressure range from atmospheric pressure to 23 kbar and at temperatures ranging from room temperature to 150 °C. Two representative examples demonstrate the use of the developed device in organic synthesis.
-
3. X-ray spectroscopy of hot dense plasmas using LLNL's upgraded Titan 2ω short-pulse laser.
3. 使用劳伦斯利弗莫尔国家实验室升级版泰坦2ω短脉冲激光对高温稠密等离子体进行X射线光谱学研究PMID:日期:2026-10-01We are developing an experimental platform at Lawrence Livermore National Laboratory's Jupiter Laser Facility to characterize x-ray emission from highly charged ions in the high-density (ne > 1023 cm-3), high-temperature (Te ∼ 1 keV) regime, leveraging the recently upgraded frequency-doubled short-pulse Titan laser. These measurements will provide experimental benchmarks for high electron density effects on atomic structure, including Stark broadening, ionization potential depression, density-dependent line shifts, and suppression of dielectronic recombination, effects that are relevant to spectral modeling packages used by both the high-energy-density and astrophysics communities. Here, we describe the current status of the platform and present results from first experiments using the upgraded frequency-doubling capability, including calibrated K-shell spectra acquired from five time-integrated x-ray channels. Comparisons with multi-electron radiator line shape calculations and with spectra recorded at the atomic weapons establishment's Orion Laser Facility indicate that the upgraded Titan laser reliably produces the necessary plasma conditions, establishing a foundation for systematic benchmarking of high-density atomic physics in future campaigns.
-
4. First results from the time resolved opacity spectrometer on the National Ignition Facility (invited).
4. 国家点火装置上时间分辨不透明度光谱仪的首批结果(特邀)PMID:日期:2026-10-01Radiative opacity plays a central role in determining stellar structure, with iron contributing significantly to the solar opacity, particularly near the radiation-convection boundary. Current atomic models of opacity remain a major source of uncertainty, factoring into discrepancies between standard solar models and helioseismic observations. Agreement with models could be attained if key opacity values were 10%-50% larger, motivating high-precision experimental benchmarks at stellar interior conditions. The Opacity-on-National Ignition Facility campaign measures iron opacity via x-ray transmission through samples heated in a hohlraum. Previous measurements using the time-integrated opacity spectrometer (OpSpec) have been limited to temperatures <160 eV and electron densities ∼1021-1022 cm-3. Higher temperatures are achievable, but measurements were precluded by strong background emission. To address this limitation, a new time-resolved spectrometer, OpSpecTR, was developed. OpSpecTR employs an elliptically bent crystal and a grazing-incidence x-ray mirror to achieve high spectral purity, and a small crossover slit to minimize background. Time-resolved spectra in the 1-2 keV range are recorded on three ns-gated hCMOS detectors, simultaneously measuring transmitted, backlighter, and self-emission signals required for opacity extraction. Nanosecond-scale gating isolates the backlighter pulse and reduces background contributions by up to 70%. Spectral resolving power is also improved ∼2× relative to the time-integrated instrument. The first results from OpSpecTR presented herein demonstrate significantly improved fidelity in opacity measurements under high-temperature conditions, advancing experimental constraints on stellar opacity models.
-
5. Approaching the intrinsic bandwidth limit: A unified method for balanced homodyne detector design.
PMID:日期:2026-10-01In this paper, we present a unified method for designing balanced homodyne detectors (BHDs) approaching the intrinsic bandwidth limit, based on either transimpedance amplifier (TIA) or low-noise amplifier (LNA) architectures. Unlike conventional design approaches that consider only the frequency response of the readout circuit, the proposed method incorporates the photodiode carrier transit time. The analysis reveals that when the carrier transit time becomes comparable to the rise time of the readout circuit, the overall detector bandwidth is governed by their combined effect rather than by a single dominant mechanism. In the TIA configuration, accounting for this joint contribution, this method eliminates the systematic bandwidth overestimation inherent in traditional single-mechanism models and consistently explains the observed strong bias-voltage dependence and the reduced optimal feedback capacitance. In contrast, in the LNA configuration, the photodiode carrier transit time becomes the dominant bandwidth constraint, making bias-voltage optimization more critical for bandwidth extension. Guided by the proposed method, a BHD employing an S3883 photodiode and cascaded LNAs was designed and optimized, achieving a 3-dB bandwidth of 210 MHz and a signal-to-noise ratio of 11.3 dB at this frequency. The measured performance agrees well with the theoretical analysis, thereby validating its predictive capability and demonstrating its practical value for high-bandwidth BHD design.
-
6. Development of an ultrahigh-vacuum-compatible cryogen-free scanning nitrogen-vacancy magnetometer.
PMID:日期:2026-10-01Scanning nitrogen-vacancy (NV) magnetometry has emerged as a powerful technique for nanoscale magnetic imaging owing to its high spatial resolution, high magnetic sensitivity, and noninvasive optical readout. For low-temperature operation, existing scanning NV microscopes have been implemented in different cryogenic systems, including liquid-helium cryostats and closed-cycle refrigerators. However, ultrahigh-vacuum compatibility and in situ sample/probe exchange remain largely unavailable in these systems, hindering measurements on pristine and surface-sensitive quantum materials. Here, we report a cryogen-free ultrahigh-vacuum scanning nitrogen-vacancy microscope equipped with an in-vacuum three-axis vector superconducting magnet, reaching a base pressure of 2 × 10-10 Torr and sample temperatures down to 2 K. The system enables in situ exchange and separate temperature control of both the sample and the probe. A pillar-array diamond probe architecture is implemented to provide flexible selection of NV centers with different crystallographic orientations, allowing access to complementary magnetic-field projections of a single spin texture. System performance is verified through thermal characterization, single-NV characterization, NV-sample distance calibration, and magnetic imaging demonstrations, which include imaging the same skyrmion bubble with two nitrogen-vacancy centers of different orientations in CoFeB and resolving individual superconducting vortices in bulk NbSe2.
-
7. Diagnosis of compound fault of bearing with improve 1D local binary patterns and vector bispectrum.
PMID:日期:2026-10-01When bearing failure occurs, the fault information in the vibration signals is characterized by weakness, complexity, and a compound nature, making it difficult to accurately identify the compound fault of the bearing. 1D local binary patterns (1D-LBP) depict fault information of bearings from the aspect of local analysis. Unexpectedly, the quantitative 1D-LBP shows no consideration of the features of signals caused by bearing failure. Therefore, it is difficult to correctly quantize signals and extract failure information. The root mean square, an effective indicator of impact signatures in bearing faults, serves as the quantitative criterion for enhancing the 1D-LBP approach. Furthermore, signal fusion is applied to improve 1D-LBP, and quantized reconstructed signals are blended based on the harmonic fusion vector bispectrum (HFVB) to enhance failure features. Finally, the extraction of failure features and identification of faults in bearings are carried out through spectral analysis. The result of the comparison indicates that the proposed improved 1D-ILBP-HFVB method can extract feature information more accurately during bearing faults while effectively suppressing noise and distinguishing compound fault types in rolling bearings.
-
8. Characterization and optimization of a laser-produced x-ray source for x-ray radiography.
PMID:日期:2026-10-01High-resolution x-ray radiography (HRXR) is a critical diagnostic tool for studying high-energy-density plasmas in large laser facilities such as the National Ignition Facility, the Laser Mega Joule, and Omega Extended Performance. However, geometric constraints in these facilities pose significant challenges for experimental design. This paper presents a comprehensive characterization of a picosecond laser-driven x-ray source tailored for HRXR applications. Through systematic experimental investigations, we analyzed the influence of various parameters on the performance of the x-ray source, focusing on spatial resolution and spectral distribution across a broad energy range. Our findings reveal that a single thin wire, comparable in diameter to the laser focal spot, positioned at 90° relative to the laser axis, serves as the optimal backlighter configuration. This configuration maximizes spatial resolution and spectral quality, addressing the geometric limitations inherent in large-scale laser facilities. The results provide a robust foundation for designing HRXR experiments, enabling more precise and reliable imaging of high-energy-density plasmas.
-
9. Investigation of injected laser polarization effects in quantum beat spectroscopy for magnetic field measurements in plasmas.
PMID:日期:2026-10-01Magnetic fields exert a strong influence on plasma behavior, highlighting the need for diagnostic techniques that can measure magnetic fields with high accuracy while minimizing plasma perturbation. Quantum Beat Spectroscopy (QBS), recently demonstrated by Gilbert et al. [Plasma Sources Sci. Technol. 34 025020 (2025)] in a laboratory plasma, is a laser-based optical diagnostic that provides Doppler-free measurements of magnetic field strength. In this study, a femtosecond laser is employed in an argon plasma to investigate the dependence of the QBS signal on the polarization of the incident laser. The experiments are conducted in a tabletop six-way cross vacuum chamber. A pair of Helmholtz coils is mounted on a rotational stage such that the chamber remains centered between the coils, enabling precise control over the orientation of the applied magnetic field. The present study shows that the quantum beat amplitude strongly depends on the polarization of the injected laser. It is also demonstrated that excitation from a single initial state into a coherent superposition of two excited magnetic sublevels is a necessary condition for the observation of quantum beats. Furthermore, it is shown that the magnetic field orientation can be determined by rotating the polarization of the injected laser.
-
10. Machine-learning-based model for motional Stark effect calibrations.
PMID:日期:2026-10-01The motional Stark effect (MSE) diagnostic on the Korea Superconducting Tokamak Advanced Research (KSTAR) device requires a beam-into-gas calibration to remove the Faraday-rotation contribution to the measured polarization angle. Because the secondary-neutral emission that contaminates this calibration grows with the torus gas pressure, the calibration is obtained by measuring the polarization angle over a range of pressures at a fixed vacuum field and extrapolating to zero pressure. Such measurements, however, exist only for a finite and irregularly sampled set of the major experimental parameters-the neutral-beam energy, the toroidal magnetic field, and the beam source-so that a calibration matching a given plasma discharge frequently does not exist and the conventional remedy of a simple linear interpolation between the nearest calibrated points remains incomplete. This work develops a supervised machine-learning model that infers the deviation of the MSE-measured polarization angle from the vacuum field for an arbitrary combination of these parameters, using the beam-into-gas data accumulated over the KSTAR FY2025 and FY2026 campaigns. A two-stage scheme that first reproduces the zero-pressure extrapolation and then learns the configuration dependence of the resulting angle is found to perform best. The improvement over the conventional linear-interpolation approach is demonstrated through the magnetic-axis evolution and through the safety factor and current density profiles of off-axis current-drive discharges.