优势双电荷离子实现新型小分子抗菌药物Cefidelbaz在人血浆中的稳健LC-MS/MS定量及其在药代动力学和蛋白结合研究中的应用
Dominant doubly charged ion enabling robust LC-MS/MS quantification of a novel small-molecule antibacterial drug Cefidelbaz in human plasma and its application to pharmacokinetic and protein binding studies.
Chenxin Ding, Xiuyang Li, Yijue Wu, Jun Wang, Shuai Wang, Yiya Wang, Li Ding
摘要(中文译文)
头孢地尔巴兹是一种新型铁载体头孢菌素类抗菌药物,具有独特的“特洛伊木马”机制,可对抗部分最难治疗的革兰阴性菌感染。在质谱分析中,头孢地尔巴兹在第一四极杆全扫描(Q1全扫描)的正离子模式和负离子模式下均产生不同的前体离子,而在正离子模式下观察到多个具有不同电荷态的前体离子。值得注意的是,正离子模式或负离子模式下的单电荷前体离子均无法提供宽线性范围和高灵敏度,而双电荷前体离子则能够实现可靠且可重现的定量分析。这些发现,结合已报道的具有两性离子特性的头孢菌素类药物的电荷态行为,表明应根据实验定量性能选择最佳前体离子。本研究建立了两种独立的液相色谱-串联质谱(LC-MS/MS)方法。第一种方法用于定量人血浆中头孢地尔巴兹的总量,校准范围为1.00-600 µg/mL。第二种方法基于超滤结合LC-MS/MS,用于测定血浆蛋白结合率(%PPB),校准范围为0.500-250 µg/mL。总体而言,本研究证明了前体离子选择对于具有两性离子特性的头孢菌素类药物进行可靠LC-MS/MS定量分析的重要性,并提供了经过验证的生物分析方法以支持头孢地尔巴兹的临床开发。
Abstract
Cefidelbaz is a novel siderophore cephalosporin antibacterial agent with a unique "Trojan horse" mechanism, which can combat some of the most difficult-to-treat Gram-negative bacterial infections. In mass spectrometric analysis, cefidelbaz generated distinct precursor ions in both positive and negative modes during the first-quadrupole full-scan (Q1 full-scan), while multiple precursor ions with different charge states were observed in positive mode. Notably, singly charged precursor ions in either positive or negative mode failed to provide wide linear range and high sensitivity, whereas the doubly charged precursor ions enabled reliable and reproducible quantitative analysis. These findings, together with reported charge-state behavior of cephalosporins with zwitterionic character, demonstrated that the optimal precursor ions should be selected according to experimental quantitative performance. Here, two independent LC-MS/MS (liquid chromatography-tandem mass spectrometry) methods were developed. The first method was established for the quantification of total cefidelbaz in human plasma, with a calibration range of 1.00-600 µg/mL. The second method, based on ultrafiltration coupled with LC-MS/MS, was developed for the determination of plasma protein binding (%PPB), covering a calibration range of 0.500-250 µg/mL. Overall, this study demonstrated the importance of precursor ions selection for reliable LC-MS/MS quantification of cephalosporins with zwitterionic character and provides validated bioanalytical methods to support clinical development of cefidelbaz.
如何引用
AMAChenxin Ding, Xiuyang Li, Yijue Wu, Jun Wang, Shuai Wang, Yiya Wang, et al. Dominant doubly charged ion enabling robust LC-MS/MS quantification of a novel small-molecule antibacterial drug Cefidelbaz in human plasma and its application to pharmacokinetic and protein binding studies.. Journal of pharmaceutical and biomedical analysis. 2027; doi:10.1016/j.jpba.2026.117725.
APAChenxin Ding, Xiuyang Li, Yijue Wu, Jun Wang, Shuai Wang, Yiya Wang, et al (2027). Dominant doubly charged ion enabling robust LC-MS/MS quantification of a novel small-molecule antibacterial drug Cefidelbaz in human plasma and its application to pharmacokinetic and protein binding studies.. Journal of pharmaceutical and biomedical analysis. https://doi.org/10.1016/j.jpba.2026.117725
GB/T 7714Chenxin Ding, Xiuyang Li, Yijue Wu, Jun Wang, Shuai Wang, Yiya Wang, et al. Dominant doubly charged ion enabling robust LC-MS/MS quantification of a novel small-molecule antibacterial drug Cefidelbaz in human plasma and its application to pharmacokinetic and protein binding studies.[J]. Journal of pharmaceutical and biomedical analysis, 2027 doi:10.1016/j.jpba.2026.117725.
在 PubMed增强版 阅读全文
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出