高功率光固化模式对无盖体填充树脂复合材料力学和光学性能的影响
Influence of high-power light-curing modes on the mechanical and optical properties of no-cap bulk-fill resin composites.
Influence of high-power light-curing modes on the mechanical and optical properties of no-cap bulk-fill resin composites.
无帽大块填充树脂复合材料的临床性能在很大程度上取决于充分的聚合,聚合程度同时影响机械耐久性和光学稳定性。尽管当代高功率光固化装置(LCUs)提供了超快速固化模式,但关于其对现代大块填充材料影响的证据仍然有限。本体外研究旨在评估VALO和Bluephase PowerCure不同聚合模式对无帽大块填充树脂复合材料显微硬度和颜色稳定性的影响。研究考察了四种无帽大块填充树脂复合材料(Omnichroma Bulk Flow、Charisma Bulk Flow ONE、Simplishade Bulk Fill和Admira Fusion x-tra)。制备了200个圆柱形试件(厚度3 mm),使用两种光固化装置(VALO和Bluephase PowerCure)在五种固化模式下进行聚合(VALO Standard、High Power和Xtra;Bluephase High Power和PowerCure)。24小时后测量顶面和底面的维氏显微硬度,并计算底顶硬度比作为固化深度的指标。记录基线颜色,并在37 °C咖啡浸泡12天后重新测量,计算颜色变化(ΔE₀₀)。数据采用双因素方差分析和对齐秩变换方差分析(α = 0.05)进行分析。复合材料类型、聚合模式及其交互作用显著影响底顶硬度比、显微硬度和颜色变化值(p < 0.001)。VALO Standard和VALO High Power通常比3秒超短固化模式产生更高的底顶硬度比和底面显微硬度值。在测试条件下,Admira Fusion x-tra和Simplishade Bulk Fill通常表现出较高的显微硬度值和/或较低的ΔE₀₀值,而Omnichroma Bulk Flow和Charisma Bulk Flow ONE在某些超短固化组中表现出较低的底顶硬度比或较高的ΔE₀₀值。在测试的材料-固化模式组合中,未观察到ΔE₀₀与底顶硬度比之间存在一致的相关性。聚合模式和总辐射暴露量影响了所测试无帽大块填充树脂复合材料的机械和光学结果。与3秒超短固化方案相比,具有更高辐射暴露量的较长暴露方案通常产生更有利的底顶硬度比和底面显微硬度值。研究结果表明,超快速固化模式可能无法为所有无帽大块填充树脂复合材料提供等效的结果。因此,选择固化方案时应考虑材料特异性行为、暴露时间和总辐射暴露量。
The clinical performance of no-cap bulk-fill resin composites depends strongly on adequate polymerization, which influences both mechanical durability and optical stability. Although contemporary high-power light-curing units (LCUs) provide ultra-fast curing modes, evidence regarding their effects on modern bulk-fill materials remains limited. This in vitro study aimed to evaluate the influence of different polymerization modes of VALO and Bluephase PowerCure on the microhardness and color stability of no-cap bulk-fill resin composites. Four no-cap bulk-fill resin composites (Omnichroma Bulk Flow, Charisma Bulk Flow ONE, Simplishade Bulk Fill, and Admira Fusion x-tra) were investigated. Two hundred cylindrical specimens (3 mm thickness) were prepared and polymerized using two LCUs (VALO and Bluephase PowerCure) under five curing modes (VALO Standard, High Power, and Xtra; Bluephase High Power and PowerCure). Vickers microhardness was measured on the top and bottom surfaces after 24 h, and bottom-to-top hardness ratios were calculated as an indicator of depth of cure. Baseline color was recorded and remeasured after 12-day coffee immersion at 37 °C, and color change (ΔE₀₀) was calculated. Data were analyzed using two-way ANOVA and Aligned Rank Transform ANOVA (α = 0.05). Composite type, polymerization mode, and their interaction significantly affected bottom-to-top hardness ratio, microhardness, and color change values (p < 0.001). VALO Standard and VALO High Power generally produced higher bottom-to-top hardness ratios and bottom-surface microhardness values than the 3-second ultra-short curing modes. Admira Fusion x-tra and Simplishade Bulk Fill generally showed higher microhardness values and/or lower ΔE₀₀ values under the tested conditions, whereas Omnichroma Bulk Flow and Charisma Bulk Flow ONE showed lower bottom-to-top hardness ratios or higher ΔE₀₀ values in some ultra-short curing groups. No consistent correlation was observed between ΔE₀₀ and bottom-to-top hardness ratio across the tested material-curing mode combinations. Polymerization mode and total radiant exposure influenced the mechanical and optical outcomes of the tested no-cap bulk-fill resin composites. Longer exposure protocols with higher radiant exposure generally resulted in more favorable bottom-to-top hardness ratios and bottom-surface microhardness values than the 3-second ultra-short curing protocols. The findings suggest that ultra-rapid curing modes may not provide equivalent outcomes for all no-cap bulk-fill resin composites. Therefore, curing protocols should be selected with consideration of material-specific behavior, exposure time, and total radiant exposure.
Betül Kübra Kurucu Karadeni̇z, Merve Kütük Ömeroğlu. Influence of high-power light-curing modes on the mechanical and optical properties of no-cap bulk-fill resin composites.. BMC oral health. 2026; doi:10.1186/s12903-026-09271-w.
Betül Kübra Kurucu Karadeni̇z, Merve Kütük Ömeroğlu (2026). Influence of high-power light-curing modes on the mechanical and optical properties of no-cap bulk-fill resin composites.. BMC oral health. https://doi.org/10.1186/s12903-026-09271-w
Betül Kübra Kurucu Karadeni̇z, Merve Kütük Ömeroğlu. Influence of high-power light-curing modes on the mechanical and optical properties of no-cap bulk-fill resin composites.[J]. BMC oral health, 2026 doi:10.1186/s12903-026-09271-w.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出