降低辐射剂量和对比剂剂量同时提高双能CT肺动脉造影图像质量的可行性:使用低能虚拟单色图像结合深度学习图像重建算法
Feasibility of reducing radiation dose and contrast dose while improving image quality in dual-energy CT pulmonary angiography : Use of low-energy virtual monochromatic images with deep learning image reconstruction algorithm.
Zhanli Ren, Tianli Wang, Li Shen, Min Zhang, Dong Han, Nan Yu, Zhanliang Ren
摘要(中文译文)
我们探讨了在高设置深度学习图像重建(DLIR-H)的双能计算机断层扫描(CT)肺动脉造影(DECTPA)中,使用低能虚拟单色图像(VMI)在降低辐射剂量和对比剂剂量的同时改善图像质量的可行性。共60例计划行CTPA的患者被随机分为两组:A组(n=30)采用120 kV、对比剂剂量0.8 mL/kg、60%强度水平的自适应统计迭代重建-V(ASIR-V);B组(n=30)采用双能CT(DECT)、对比剂剂量0.6 mL/kg、40 keV、50 keV、60 keV和70 keV VMI的DLIR-H。测量肺动脉的CT值和标准差(SD)值以计算信噪比(SNR)和对比噪声比(CNR)。图像质量由两名放射科医师采用五分法进行盲法主观评分。两组患者的一般人口学资料无差异(均p > 0.05)。与A组相比,B组的对比剂剂量和辐射剂量分别降低29.6%和53.1%(p < 0.05)。与A组相比,B组40 keV-60 keV VMI的CT值和SNR值显著更高,40 keV-70 keV VMI的CNR更高(均p < 0.05),60 keV时图像噪声相似。两名放射科医师的主观评分具有高度一致性(kappa > 0.80)。B组40 keV-60 keV VMI的评分显著高于A组(均p < 0.05),其中40 keV VMI评分最高。在DECTPA中,DLIR-H联合VMI(尤其是40 keV)可在降低对比剂剂量和辐射剂量的同时改善图像质量。
Abstract
We explored the feasibility of reducing both radiation and contrast doses while improving image quality using low-energy virtual monochromatic images (VMIs) in dual-energy computed tomography (CT) pulmonary angiography (DECTPA) with deep learning image reconstruction at a high setting (DLIR-H). A total of 60 patients scheduled for CTPA were randomly divided into two groups: group A (n = 30) with 120 kV, contrast dose of 0.8 mL/kg, and adaptive statistical iterative reconstruction‑V (ASIR-V) at a 60% strength level, and group B (n = 30) with dual-energy CT (DECT), contrast dose of 0.6 mL/kg, and DLIR‑H at 40 keV, 50 keV, 60 keV and 70 keV VMIs. The CT and standard deviation (SD) values of the pulmonary arteries were measured to calculate the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Image quality was subjectively scored blindly by two radiologists using a five-point scale. There were no differences in general patient demographics between the two groups (all p > 0.05). In group B, the contrast and radiation doses decreased by 29.6% and 53.1%, respectively, compared to group A (p < 0.05). Compared to group A, group B had significantly higher CT and SNR values for the 40 keV-60 keV VMIs and higher CNR for the 40 keV-70 keV VMIs (all p < 0.05), with similar image noise at 60 keV. The two radiologists had substantial agreement in subjective scoring (kappa > 0.80). There were significantly higher scores for the 40 keV-60 keV VMIs in group B compared to group A (all p < 0.05), with the 40 keV VMIs having the highest scores. Combining DLIR‑H with VMIs, especially 40 keV, in DECTPA leads to reduced contrast and radiation doses while improving image quality.
如何引用
AMAZhanli Ren, Tianli Wang, Li Shen, Min Zhang, Dong Han, Nan Yu, et al. Feasibility of reducing radiation dose and contrast dose while improving image quality in dual-energy CT pulmonary angiography : Use of low-energy virtual monochromatic images with deep learning image reconstruction algorithm.. Radiologie (Heidelberg, Germany). 2026; doi:10.1007/s00117-026-01653-z.
APAZhanli Ren, Tianli Wang, Li Shen, Min Zhang, Dong Han, Nan Yu, et al (2026). Feasibility of reducing radiation dose and contrast dose while improving image quality in dual-energy CT pulmonary angiography : Use of low-energy virtual monochromatic images with deep learning image reconstruction algorithm.. Radiologie (Heidelberg, Germany). https://doi.org/10.1007/s00117-026-01653-z
GB/T 7714Zhanli Ren, Tianli Wang, Li Shen, Min Zhang, Dong Han, Nan Yu, et al. Feasibility of reducing radiation dose and contrast dose while improving image quality in dual-energy CT pulmonary angiography : Use of low-energy virtual monochromatic images with deep learning image reconstruction algorithm.[J]. Radiologie (Heidelberg, Germany), 2026 doi:10.1007/s00117-026-01653-z.
在 PubMed增强版 阅读全文
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出
Radiologie (Heidelberg, Germany) 的其他文献