心血管磁共振指导左心室射血分数36%至50%患者的除颤器植入:CMR GUIDE随机临床试验
Cardiovascular Magnetic Resonance to Guide Defibrillator Implantation for LVEF of 36% to 50%: The CMR GUIDE Randomized Clinical Trial.
Cardiovascular Magnetic Resonance to Guide Defibrillator Implantation for LVEF of 36% to 50%: The CMR GUIDE Randomized Clinical Trial.
现行指南不建议将植入式心律转复除颤器(ICD)用于一级预防,除非患者的左心室射血分数(LVEF)为35%或以下。许多心脏性猝死(SCD)发生在LVEF为36%至50%时。心肌瘢痕(一种关键的心律失常基质)可通过心血管磁共振(CMR)上的晚期钆增强进行评估,但关于基于瘢痕的ICD植入策略,尚缺乏有力证据。旨在确定在LVEF为36%至50%且存在心肌瘢痕的患者中,植入ICD是否能减少SCD或血流动力学显著的室性心律失常(HSVA)。一项开放标签随机临床试验于2015年至2022年纳入成人患者,这些患者患有缺血性或非缺血性心肌病、LVEF为36%至50%、经CMR定义存在心肌瘢痕,并正在接受指南指导的药物治疗,研究在澳大利亚、德国和英国的18个中心进行。随访评估于2026年完成。干预措施为一级预防性ICD(n=180)对比植入式循环记录器(ILR)(n=173)。主要复合结局为SCD或HSVA。评估了五项次要结局:SCD、HSVA、心力衰竭相关住院、心血管死亡和全因死亡。在353例随机化患者中(中位年龄65岁[IQR,57-61岁];18%为女性;72%为缺血性病因),70%的患者LVEF为40%或以上。中位随访时间为6.3年(IQR,4.8-7.6年)。主要复合结局在ICD组发生14例(7.8%),而ILR组发生16例(9.2%)(风险比[HR],0.76[95%CI,0.37-1.58])。对于主要复合结局的各单独组分,SCD在ICD组发生3例(1.7%),而ILR组发生10例(5.8%)(HR,0.26[95%CI,0.07-0.95]);HSVA分别发生12例(6.7%)和6例(3.5%)(HR,1.77[95%CI,0.65-4.81])。两组在全因死亡、心血管死亡和心力衰竭相关住院的发生率方面相似。在一项对6个亚组的事先指定分析中,主要结局在ICD组70岁以下患者中发生较少(3.3%),而ILR组为10.0%(HR,0.28[95%CI,0.09-0.89]),但在70岁及以上患者中并非如此(分别为16.9%和7.5%)(HR,2.33[95%CI,0.75-7.26];交互作用P=0.01)。在LVEF为36%至50%且存在心肌瘢痕的患者中,植入ICD并未减少SCD或HSVA的复合结局。ClinicalTrials.gov标识符:NCT01918215。
Current guidelines do not recommend primary prevention implantable cardioverter-defibrillators (ICDs) unless a patient's left ventricular ejection fraction (LVEF) is 35% or less. Many sudden cardiac deaths (SCD) occur when LVEF is 36% to 50%. Myocardial scar (a key arrhythmic substrate) can be assessed by late gadolinium enhancement on cardiovascular magnetic resonance (CMR), but robust evidence is lacking regarding a scar-based approach to ICD insertion. To determine whether implantation of ICDs reduces SCD or hemodynamically significant ventricular arrhythmia (HSVA) in patients with an LVEF of 36% to 50% and myocardial scar. An open-label randomized clinical trial enrolled adults between 2015 and 2022 who had ischemic or nonischemic cardiomyopathy, an LVEF of 36% to 50%, CMR-defined myocardial scar, and were receiving guideline-directed medical therapy at 18 sites in Australia, Germany, and the UK. Follow-up assessments were completed in 2026. A primary prevention ICD (n = 180) vs an implantable loop recorder (ILR) (n = 173). The primary composite outcome was SCD or HSVA. Five secondary outcomes were evaluated: SCD, HSVA, heart failure-related hospitalization, cardiovascular mortality, and all-cause mortality. Of 353 patients randomized (median age, 65 years [IQR, 57-61 years]; 18% female; and 72% had an ischemic etiology), 70% had an LVEF of 40% or greater. The median follow-up was 6.3 years (IQR, 4.8-7.6 years). The primary composite outcome occurred in 14 patients (7.8%) in the ICD group compared with 16 patients (9.2%) in the ILR group (hazard ratio [HR], 0.76 [95% CI, 0.37-1.58]). For the individual components of the primary composite outcome, SCD occurred in 3 patients (1.7%) vs 10 patients (5.8%) in the ILR group (HR, 0.26 [95% CI, 0.07-0.95]) and HSVA occurred in 12 patients (6.7%) vs 6 patients (3.5%), respectively (HR, 1.77 [95% CI, 0.65-4.81]). The rates for all-cause mortality, cardiovascular mortality, and heart failure-related hospitalization were similar between groups. In a prespecified analysis of 6 subgroups, the primary outcome occurred less often in patients younger than 70 years in the ICD group (3.3%) vs patients in the ILR group (10.0%) (HR, 0.28 [95% CI, 0.09-0.89]) but not in those aged 70 years or older (16.9% vs 7.5%, respectively) (HR, 2.33 [95% CI, 0.75-7.26]; P = .01 for interaction). Implantation of an ICD did not reduce the composite outcome of SCD or HSVA in patients with an LVEF of 36% to 50% and myocardial scar. ClinicalTrials.gov Identifier: NCT01918215.
Joseph B Selvanayagam, John G F Cleland, Graham S Hillis, Sivabaskari Pasupathy, Laurent Billot, Katherine E George, et al. Cardiovascular Magnetic Resonance to Guide Defibrillator Implantation for LVEF of 36% to 50%: The CMR GUIDE Randomized Clinical Trial.. JAMA. 2026; doi:10.1001/jama.2026.17078.
Joseph B Selvanayagam, John G F Cleland, Graham S Hillis, Sivabaskari Pasupathy, Laurent Billot, Katherine E George, et al (2026). Cardiovascular Magnetic Resonance to Guide Defibrillator Implantation for LVEF of 36% to 50%: The CMR GUIDE Randomized Clinical Trial.. JAMA. https://doi.org/10.1001/jama.2026.17078
Joseph B Selvanayagam, John G F Cleland, Graham S Hillis, Sivabaskari Pasupathy, Laurent Billot, Katherine E George, et al. Cardiovascular Magnetic Resonance to Guide Defibrillator Implantation for LVEF of 36% to 50%: The CMR GUIDE Randomized Clinical Trial.[J]. JAMA, 2026 doi:10.1001/jama.2026.17078.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出