Dosimetric impact of daily skin surface variations in kidney stereotactic ablative proton therapy.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

质子束治疗(PBT)是肾脏立体定向消融放疗(SABR)中一种有前景的模式。然而,PBT对射束路径中材料的敏感性要求在患者体位固定方面需特别考虑。在临床实践中,我们观察到皮肤表面存在显著变异性,这可能扰动实际递送的剂量。在此,我们表征了肾脏立体定向体部质子治疗(SBPT)中皮肤表面变异的影响。纳入2024年至2025年间接受肾脏SBPT治疗的患者。评估计划在稳健优化中采用3.0 mm摆位不确定性创建,以5次分次给予处方剂量50 Gy(RBE)至99%的靶体积(iCTV)。通过将计划扫描的HU映射至治疗当日CBCT上生成虚拟CT,用于剂量累积。将评估计划映射至每组虚拟CT。比较计划分布与累积分布之间95-100%靶区剂量(iCTV D95-Dmin)以及健康肾脏接受10-50 Gy的体积(V10-V50)。共纳入15例患者,治疗75分次。沿射束路径的肿瘤质心深度相对于计划解剖结构变化可达17.4 mm。22.7%的分次中深度变化超过5.0 mm,并导致iCTV D95、D98、D99和Dmin低于评估计划分布(< 0.01)。累积D99最多下降24.3%。皮肤表面变异可能损害肾脏SBPT的治疗质量。有必要进一步研究缓解策略,如自适应放疗。

Abstract

Proton beam therapy (PBT) is a promising modality in kidney stereotactic ablative radiotherapy (SABR). However, the sensitivity of PBT to materials in the beam path enforces special considerations in patient positioning. In clinical practice, we observed significant variability in the skin surface, which may perturb delivered dose. Here, we characterize the impact of skin surface variations in kidney stereotactic body proton therapy (SBPT). Patients treated with kidney SBPT between 2024 and 2025 were included. Assessment plans were created using 3.0 mm positioning uncertainty in robust optimization to deliver a prescription dose of 50 Gy(RBE) in 5 fractions to 99% of the target volume (iCTV). Virtual CTs were generated for dose accumulation by mapping HU from the planning scan onto the day-of-treatment CBCT. The assessment plan was mapped to each virtual CT set. The dose to 95-100% of the target (iCTV D95-Dmin) and the volume of healthy kidney receiving 10-50 Gy (V10-V50) were compared between planned and accumulated distributions. Fifteen patients treated in 75 fractions were included. The depth of the tumor centroid along the beam path varied by up to 17.4 mm relative to the planned anatomy. Depth variations exceeded 5.0 mm in 22.7% of fractions, and resulted in lower iCTV D95, D98, D99, and Dmin ( < 0.01) compared to assessment plan distributions. The accumulated D99 dropped by up to 24.3%. Skin surface variations may compromise kidney SBPT treatment quality. Further investigation into mitigation strategies, such as adaptive radiotherapy, are merited.

如何引用

AMA

Yohan A Walter, Olivia G Moncrief, Chiachien J Wang, James C Henry, Mitchell Wolden, Emily G Warren, et al. Dosimetric impact of daily skin surface variations in kidney stereotactic ablative proton therapy.. Technical innovations & patient support in radiation oncology. 2026; doi:10.1016/j.tipsro.2026.100428.

APA

Yohan A Walter, Olivia G Moncrief, Chiachien J Wang, James C Henry, Mitchell Wolden, Emily G Warren, et al (2026). Dosimetric impact of daily skin surface variations in kidney stereotactic ablative proton therapy.. Technical innovations & patient support in radiation oncology. https://doi.org/10.1016/j.tipsro.2026.100428

GB/T 7714

Yohan A Walter, Olivia G Moncrief, Chiachien J Wang, James C Henry, Mitchell Wolden, Emily G Warren, et al. Dosimetric impact of daily skin surface variations in kidney stereotactic ablative proton therapy.[J]. Technical innovations & patient support in radiation oncology, 2026 doi:10.1016/j.tipsro.2026.100428.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI