定义低成本MSLA 3D打印用于微流控系统的操作极限:树脂性能、细胞相容性和流体动力学

Defining Operational Limits of Low-Cost MSLA 3D Printing for Microfluidic Systems: Resin Performance, Cell Compatibility, and Fluid Dynamics.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

利用低成本掩膜立体光刻技术的增材制造是实现微流控器件制造民主化的一种有吸引力的选择,尽管其空间分辨率、光学透明度、细胞毒性和复制性等方面存在局限性,需要加以解决。本研究系统研究了在Anycubic Photon M7 Pro低成本打印机中使用的五种透明掩膜立体光刻树脂,以解决上述局限性。工作路线基于对阴性和阳性微特征尺寸、透射光谱、细胞毒性、构建内部通道的能力、在PDMS中的可复制性以及通过计算流体动力学模拟与实验流体测定进行验证的分析。分辨率测试表明,由于逐层打印过程中细微的树脂积累,阴性结构的解析精度较低。内部通道制造显示,在本研究所用的打印和后处理条件下,实际下限约为500 μm,树脂粘度、打印角度和排液行为强烈影响通道间隙。Standard V2和High Clear树脂表现出最高的打印分辨率,微通道以垂直或几乎垂直的位置打印。关于热固化PDMS复制,Tough Ultra、ABS-like Pro 2和Water-Wash表现出最准确的结果。从生物学角度来看,所有树脂均无细胞毒性,其中Standard V2和High Clear表现出最高的细胞活力,在某些情况下优于对照场景。接触角测量表明,Standard V2和High Clear树脂具有高度亲水性,而其余树脂表现出疏水行为。溶胀被发现依赖于介质,其中Water-Wash在Milli-Q水和PBS中表现出高溶胀,Tough Ultra在乙醇中表现出高溶胀。样品仅受异丙醇的轻微影响。最后,在三种不同的微流控芯片上进行了流体流动测定,以证明引入微特征和锯齿形架构通过引入二次流和涡量来促进层流条件的破坏,从而模拟更生理的环境。这些实验与计算流体动力学进行的模拟进行了对比。经验证,微特征可以充分实现在芯片架构中并导致增强的混合。该验证使得能够定义MSLA 3D打印机用于微流控的实用操作窗口。

Abstract

Additive manufacturing using low-cost masked stereolithography technology is an attractive option to democratize microfluidic devices fabrication, albeit with limits in spatial resolution, optical transparency, cytotoxicity, and replication that need to be addressed. In this work, five transparent masked stereolithography resins employed in an Anycubic Photon M7 Pro low-cost printer are systematically studied to address the limitations mentioned above. The working route was based on the analysis of the dimensions of negative and positive microfeatures, their transmission spectra, their cytotoxicity, the capability of building internal channels, replicability in PDMS, and validation by computational fluid dynamics simulations with experimental fluid assays. Resolution tests revealed that negative structures resolved less accurately due to subtle resin accumulation during the layer-by-layer printing process. Internal channel fabrication showed a practical lower limit of approximately 500 μm under the printing and postprocessing conditions used in the study, with resin viscosity, printing angle, and drainage behavior strongly influencing channel clearance. The Standard V2 and High Clear resins exhibited the highest printing resolution with microchannels printed in a vertical or almost-vertical position. Regarding thermally cured PDMS replication, the Tough Ultra, ABS-like Pro 2, and Water-Wash were the ones exhibiting the most accurate outcome. From a biological point of view, all resins were non-cytotoxic, with Standard V2 and High Clear exhibiting the highest cell viability, in some cases better than the control scenario. Contact angle measurements indicated that the Standard V2 and High Clear resins are highly hydrophilic, whereas the remaining resins exhibit a hydrophobic behavior. Swelling was found to be dependent on the media, where the Water-Wash found high swelling in Milli-Q water and PBS and the Tough Ultra in ethanol. Samples were only minimally affected by isopropyl alcohol. Finally, fluid flow assays were conducted on three different microfluidic chips to demonstrate that the introduction of microfeatures and zigzag architectures fosters the disruption of laminar flow conditions by introducing secondary flows and vorticity to mimic more physiological environments. These experiments were contrasted with simulations performed by computational fluid dynamics. It was verified that microfeatures can be adequately implemented in the chip architecture and result in enhanced mixing. This validation allowed defining a practical operating window for MSLA 3D printers for microfluidics.

如何引用

AMA

Yago Radziunas-Salinas, Bárbara Blanco-Fernández, Vanessa Valdiglesias, María Teresa Flores-Arias, Carmen Bao-Varela, Ana Isabel Gómez-Varela. Defining Operational Limits of Low-Cost MSLA 3D Printing for Microfluidic Systems: Resin Performance, Cell Compatibility, and Fluid Dynamics.. ACS omega. 2026; doi:10.1021/acsomega.6c02218.

APA

Yago Radziunas-Salinas, Bárbara Blanco-Fernández, Vanessa Valdiglesias, María Teresa Flores-Arias, Carmen Bao-Varela, Ana Isabel Gómez-Varela (2026). Defining Operational Limits of Low-Cost MSLA 3D Printing for Microfluidic Systems: Resin Performance, Cell Compatibility, and Fluid Dynamics.. ACS omega. https://doi.org/10.1021/acsomega.6c02218

GB/T 7714

Yago Radziunas-Salinas, Bárbara Blanco-Fernández, Vanessa Valdiglesias, María Teresa Flores-Arias, Carmen Bao-Varela, Ana Isabel Gómez-Varela. Defining Operational Limits of Low-Cost MSLA 3D Printing for Microfluidic Systems: Resin Performance, Cell Compatibility, and Fluid Dynamics.[J]. ACS omega, 2026 doi:10.1021/acsomega.6c02218.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

ACS omega 的其他文献