尺骨茎突骨折闭合复位内固定技术的生物力学比较
A biomechanical comparison of closed-reduction osteosynthesis techniques for fractures of the ulnar styloid.
A biomechanical comparison of closed-reduction osteosynthesis techniques for fractures of the ulnar styloid.
尺骨茎突骨折(USF)常被低估,并可能导致具有临床意义的手腕不稳和功能预后受损。目前有多种接骨技术可用于治疗不稳定性USF。本研究旨在比较适用于闭合复位的固定方法——具体为克氏针和无头加压螺钉固定——的生物力学稳定性,以支持临床决策。本生物力学体外研究使用30个人工尺骨标本进行。通过在基底部进行标准化截骨模拟USF。创建三组各10个标本,以比较三种接骨方法:一枚1.4 mm(mm)克氏针(K-wire)(1KW组)、两枚1.0 mm克氏针(2KW组)或一枚2.0 mm空心无头螺钉(CHS组)。每个构建体均接受1,000次载荷循环,最大至50牛顿(N),随后进行失效载荷测试,失效定义为位移≥2 mm。记录并比较各组间的位移[mm]、刚度[N/mm]和失效载荷[N]。1,000次循环后的平均骨折位移在1KW组为0.58 mm(SD 0.37),在2KW组为0.23 mm(SD 0.09),在CHS组为0.09 mm(SD 0.03)。CHS与1KW之间(p < 0.01)以及CHS与2KW之间(p = 0.017)显示出显著的组间差异。平均构建体刚度在1KW组为269.95(SD 45.72)N/mm,在2KW组为484.08(SD 207.60)N/mm,在CHS组为730.95(SD 241.42)N/mm。CHS与1KW之间显示出显著的组间差异(p < 0.01)。平均失效载荷在1KW组为136.82(SD 68.86)N,在2KW组为181.60(SD 28.09)N,在CHS组为204.17(SD 63.10)N。CHS与1KW之间显示出显著的组间差异(p = 0.013)。与单枚或双枚克氏针固定相比,使用无头加压螺钉进行尺骨茎突再固定可提供更优的轴向稳定性。在治疗不稳定性USF时应考虑这一点。
Ulnar styloid fractures (USF) are frequently underestimated and can contribute to clinically relevant wrist instability and impaired functional outcomes. Several osteosynthesis techniques are available for the treatment of unstable USF. This study aims to compare the biomechanical stability of fixation methods applicable to closed reduction - specifically K-wire and headless compression screw fixation - to support clinical decision-making. This biomechanical in vitro study was conducted using 30 specimens of artificial ulnae. USF were simulated through a standardized osteotomy at the base. Three groups of ten specimens each were created to compare three methods of osteosynthesis: One 1.4 mm (mm) Kirschner-wire (K-wire) (Group 1KW), two 1.0 K-wires (Group 2KW) or one 2.0 cannulated headless screw (Group CHS). Each construct underwent 1,000 load cycles up to 50 newtons (N) followed by load-to-failure testing, which was defined as displacement ≥ 2 mm. Displacement [mm], stiffness [N/mm] and load to failure [N] were recorded and compared among the groups. The mean fracture displacement after 1,000 cycles was 0.58 mm (SD 0.37) in the 1KW group, 0.23 mm (SD 0.09) in the 2KW group and 0.09 mm (SD 0.03) in the CHS group. Significant group differences could be shown between CHS and 1KW (p < 0.01) as well as between CHS and 2KW (p = 0.017). The mean construct stiffness was 269.95 (SD 45.72) N/mm in the 1KW group, 484.08 (SD 207.60) N/mm in the 2KW group and 730.95 (SD 241.42) N/mm in the CHS group. Significant group differences could be shown between CHS and 1KW (p < 0.01). The mean load-to-failure was 136.82 (SD 68.86) N in the 1KW group, 181.60 (SD 28.09) N in the 2KW group and 204.17 (SD 63.10) N in the CHS group. Significant group differences could be shown between CHS and 1KW (p = 0.013). Ulnar styloid refixation with a headless compression screw provides superior axial stability compared to single or double K-wire fixation. This should be considered in the treatment of unstable USF.
Jonas Eck, Inska Onken, Julian P Maier, Kilian Reising, Nikos Karvouniaris, Jörg Bayer, et al. A biomechanical comparison of closed-reduction osteosynthesis techniques for fractures of the ulnar styloid.. Journal of orthopaedic surgery and research. 2026; doi:10.1186/s13018-026-07188-2.
Jonas Eck, Inska Onken, Julian P Maier, Kilian Reising, Nikos Karvouniaris, Jörg Bayer, et al (2026). A biomechanical comparison of closed-reduction osteosynthesis techniques for fractures of the ulnar styloid.. Journal of orthopaedic surgery and research. https://doi.org/10.1186/s13018-026-07188-2
Jonas Eck, Inska Onken, Julian P Maier, Kilian Reising, Nikos Karvouniaris, Jörg Bayer, et al. A biomechanical comparison of closed-reduction osteosynthesis techniques for fractures of the ulnar styloid.[J]. Journal of orthopaedic surgery and research, 2026 doi:10.1186/s13018-026-07188-2.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出