针缝比和缝合线直径对体外犬空肠造口术模型中急性漏压的影响

Impact of Needle-to-Suture Ratio and Suture Diameter on Acute Leakage Pressure in an Ex Vivo Canine Jejunal Enterotomy Model.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

术后肠漏是胃肠外科手术的严重并发症;然而,影响肠切开封合的即刻机械因素仍未被完全阐明。本离体研究在犬空肠切开模型中评估了针线比(N:S Ratio)和缝线直径与急性渗漏压力之间的关联。研究使用取自10具犬尸体的80个新鲜空肠段,对8个针线产品组进行了测试。采用随机完全区组设计,每只犬为每个缝线组提供一个空肠段。在标准化肠切开闭合后,记录初始渗漏压力(ILP)、最大腔内压力(MIP)和初始渗漏部位。采用线性混合效应模型,以缝线组为固定效应,以犬个体身份为随机截距。初始渗漏主要发生于针孔部位,占80个样本中的75个(93.75%)。缝线组对经对数转换的ILP和MIP均有显著的总体效应。在针线条件更具可比性的预设比较中,较高的针线比与较低的急性渗漏压力相关。然而,在SHMP商用缝线系列内,渗漏压力与针线比并未呈现简单的单调关系。综上,这些发现表明,在更具可比性的产品条件下,针线匹配与急性封合相关,而商用针线产品的性能不能仅用针线比来解释。这些发现提示,针孔封合是犬空肠切开闭合后急性抗渗漏能力的主要组成部分。在就针线选择提出具体建议之前,尚需进一步的体内和临床研究。

Abstract

Postoperative intestinal leakage is a serious complication of gastrointestinal surgery; however, the immediate mechanical factors affecting enterotomy sealing remain incompletely understood. This ex vivo study evaluated the association of needle-to-suture ratio (N:S Ratio) and suture diameter with acute leakage pressure in a canine jejunal enterotomy model. Eight needle-suture product groups were tested using 80 fresh jejunal segments obtained from 10 canine cadavers. A randomized complete block design was used, with each dog contributing one jejunal segment to each suture group. After standardized enterotomy closure, the initial leakage pressure (ILP), maximum intraluminal pressure (MIP), and initial leakage location were recorded. Linear mixed-effects models were used, with the suture group as a fixed effect and dog identity as a random intercept. Initial leakage occurred predominantly at the needle-hole site, accounting for 75 of the 80 samples (93.75%). The suture group had a significant overall effect on both log-transformed ILP and MIP. In predefined comparisons under more comparable needle-suture conditions, higher N:S Ratio were associated with lower acute leakage pressures. However, within the SHMP commercial suture series, leakage pressure did not follow a simple monotonic relationship with the N:S Ratio. Together, these findings indicate that needle-suture matching is relevant to acute sealing under more comparable product conditions, whereas the performance of commercial needle-suture products cannot be explained by N:S Ratio alone. These findings suggest that needle-hole sealing is a major component of acute leakage resistance after canine jejunal enterotomy closure. Further in vivo and clinical studies are required before specific recommendations regarding needle-suture selection can be made.

如何引用

AMA

Shuai Li, Xingkai Zhao, YiZhe Guo, Rongxi Yang, Yuhan Zhang, Chenhao Wu, et al. Impact of Needle-to-Suture Ratio and Suture Diameter on Acute Leakage Pressure in an Ex Vivo Canine Jejunal Enterotomy Model.. Veterinary journal (London, England : 1997). 2026; doi:10.1016/j.tvjl.2026.106848.

APA

Shuai Li, Xingkai Zhao, YiZhe Guo, Rongxi Yang, Yuhan Zhang, Chenhao Wu, et al (2026). Impact of Needle-to-Suture Ratio and Suture Diameter on Acute Leakage Pressure in an Ex Vivo Canine Jejunal Enterotomy Model.. Veterinary journal (London, England : 1997). https://doi.org/10.1016/j.tvjl.2026.106848

GB/T 7714

Shuai Li, Xingkai Zhao, YiZhe Guo, Rongxi Yang, Yuhan Zhang, Chenhao Wu, et al. Impact of Needle-to-Suture Ratio and Suture Diameter on Acute Leakage Pressure in an Ex Vivo Canine Jejunal Enterotomy Model.[J]. Veterinary journal (London, England : 1997), 2026 doi:10.1016/j.tvjl.2026.106848.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Veterinary journal (London, England : 1997) 的其他文献