通过基于磁珠的竞争化学发光平台定量HPV-16和HPV-18中和抗体

Quantification of HPV-16 and HPV-18 neutralizing antibodies via a magnetic bead-based competitive chemiluminescence platform.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

高危型人乳头瘤病毒(HPV)16型和18型的持续感染是宫颈癌的主要病因,接种疫苗是有效的预防手段。疫苗效力的评估依赖于中和抗体(nAbs)的检测。然而,广泛用作参考方法的假病毒中和试验(PBNA)存在通量低、技术复杂等局限性。为解决这一问题,我们开发了一种快速、准确的磁珠竞争性化学发光免疫分析法(CLIA),用于分别定量评估HPV-16和HPV-18中和抗体。该平台采用两种检测配置:HPV-16检测使用单克隆抗体(mAb)包被的磁珠和吖啶酯(AE)标记的抗原(Ags),而HPV-18检测使用抗原包被的磁珠和吖啶酯标记的单克隆抗体。该方法的原理是检测样本抗体对示踪物结合的竞争性抑制,产生的化学发光信号与中和抗体浓度成反比。该方法显示出可接受的分析性能,两种检测均具有良好的线性(R² > 0.999),回收率在预设的可接受范围内。使用40份疫苗接种者血清样本进行的初步比较显示,与PBNA的一致率为97.5%,且相关性良好(R² > 0.95)。在37 °C短期热应激7天后,所选分析参数总体保持可比。这些发现支持该平台的分析可行性,以及其在HPV疫苗免疫原性研究和血清学监测中的进一步评估。

Abstract

Persistent infection with high-risk human papillomavirus (HPV) types 16 and 18 is the primary cause of cervical cancer, and vaccination is an effective prevention method. The assessment of vaccine efficacy relies on measuring neutralizing antibodies (nAbs). However, the pseudovirion-based neutralization assay (PBNA), which is widely used as a reference method has limitations such as low throughput and technical complexity. To address this issue, we have developed a rapid and accurate magnetic bead-based competitive chemiluminescence immunoassay (CLIA) for the separate quantitative assessment of HPV-16 and HPV-18 nAbs. This platform uses two assay configurations: HPV-16 detection involves monoclonal antibody (mAb)-coated beads and acridinium ester (AE)-labeled antigens (Ags), while HPV-18 detection involves Ag-coated beads and AE-labeled mAbs. This assay works by measuring the competitive inhibition of tracer binding by sample Abs, resulting in a chemiluminescence signal that is inversely proportional to nAbs concentration. The method has shown acceptable analytical performance, with strong linearity (R² > 0.999) and recovery values within the predefined acceptance range for both assays. A preliminary comparison using 40 serum samples from vaccinated participants showed 97.5% agreement and a strong correlation (R² > 0.95) with PBNA. The selected analytical parameters remained generally comparable after short-term thermal stress at 37 °C for 7 days. These findings support the analytical feasibility of the platform and its further evaluation in HPV vaccine immunogenicity studies and serological monitoring.

如何引用

AMA

Linlin Wang, Weiya Mao, Zhuo Zhang, Yu-Lin Xiao, Shuhong Luo, Conghui Liao, et al. Quantification of HPV-16 and HPV-18 neutralizing antibodies via a magnetic bead-based competitive chemiluminescence platform.. Journal of virological methods. 2026; doi:10.1016/j.jviromet.2026.115452.

APA

Linlin Wang, Weiya Mao, Zhuo Zhang, Yu-Lin Xiao, Shuhong Luo, Conghui Liao, et al (2026). Quantification of HPV-16 and HPV-18 neutralizing antibodies via a magnetic bead-based competitive chemiluminescence platform.. Journal of virological methods. https://doi.org/10.1016/j.jviromet.2026.115452

GB/T 7714

Linlin Wang, Weiya Mao, Zhuo Zhang, Yu-Lin Xiao, Shuhong Luo, Conghui Liao, et al. Quantification of HPV-16 and HPV-18 neutralizing antibodies via a magnetic bead-based competitive chemiluminescence platform.[J]. Journal of virological methods, 2026 doi:10.1016/j.jviromet.2026.115452.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Journal of virological methods 的其他文献