血清miR-101-3p联合多普勒超声对多囊卵巢综合征的诊断价值:一项回顾性研究

Diagnostic value of serum miR-101-3p combined with Doppler ultrasound in polycystic ovarian syndrome: a retrospective study.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

多囊卵巢综合征(PCOS)是一种常见的内分泌疾病,目前缺乏有效的诊断生物标志物。miR-101-3p与内分泌调节和卵巢功能相关,新近证据提示其可能作为生殖障碍的生物标志物。本研究旨在探讨血清miR-101-3p联合彩色多普勒超声参数检测对PCOS的诊断价值。共纳入186例研究对象,样本采集时间为2020年4月至2023年6月。采用逆转录定量聚合酶链反应(RT-qPCR)检测miR-101-3p表达。采用彩色多普勒超声检测卵巢多普勒参数。采用Kolmogorov-Smirnov检验验证连续变量的正态性,并进行受试者工作特征(ROC)曲线分析以评估单一指标及其联合组合的诊断效能,以<0.05为差异有统计学意义。与对照组相比,PCOS患者血清miR-101-3p表达显著下调(<0.001)。PCOS患者卵巢体积显著增大(<0.01),而搏动指数和阻力指数显著降低(均<0.05)。此外,PCOS患者低血清miR-101-3p水平与高促黄体生成素水平密切相关(<0.05)。ROC曲线分析表明,miR-101-3p与多普勒参数联合组合的曲线下面积(AUC)为0.947,灵敏度为90.4%,特异度为85.4%,诊断效能显著优于任何单一指标(均<0.05)。综上所述,血清miR-101-3p联合卵巢多普勒参数检测对PCOS具有改善的诊断效能,是一种有前景的临床辅助策略。

Abstract

Polycystic ovarian syndrome (PCOS) is a common endocrine disorder with limited diagnostic biomarkers. miR-101-3p is implicated in endocrine regulation and ovarian function, with emerging evidence suggesting its potential as a biomarker for reproductive disorders. This study aimed to explore the diagnostic value of combined detection of serum miR-101-3p and colour Doppler ultrasound parameters for PCOS. A total of 186 study subjects were enrolled, with samples collected from April 2020 to June 2023. miR-101-3p expression was detected by reverse transcription-quantitative polymerase chain reaction (RT-qPCR). The Doppler parameters of the ovary were detected by colour Doppler ultrasound. The Kolmogorov-Smirnov test was used to verify the normality of continuous variables, and receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic efficacy of single indicators and their combined panel, with < 0.05 considered statistically significant. Serum miR-101-3p expression was significantly downregulated in PCOS patients compared with the control group ( < 0.001). In PCOS patients, ovarian volume was significantly elevated ( < 0.01), while pulsatility index and resistive index were significantly decreased (both < 0.05). Additionally, low serum miR-101-3p levels were closely correlated with high luteinising hormone levels in PCOS patients ( < 0.05). ROC curve analysis indicated that the combined panel of miR-101-3p and Doppler parameters achieved an area under the curve (AUC) of 0.947, with a sensitivity of 90.4% and specificity of 85.4%, showing significantly superior diagnostic performance over any single indicator (all < 0.05). In conclusion, combined detection of serum miR-101-3p and ovarian Doppler parameters exhibits improved diagnostic efficacy for PCOS, representing a promising auxiliary clinical strategy.

如何引用

AMA

Jing Zhou, Ying Sun. Diagnostic value of serum miR-101-3p combined with Doppler ultrasound in polycystic ovarian syndrome: a retrospective study.. Journal of obstetrics and gynaecology : the journal of the Institute of Obstetrics and Gynaecology. 2026; doi:10.1080/01443615.2026.2697493.

APA

Jing Zhou, Ying Sun (2026). Diagnostic value of serum miR-101-3p combined with Doppler ultrasound in polycystic ovarian syndrome: a retrospective study.. Journal of obstetrics and gynaecology : the journal of the Institute of Obstetrics and Gynaecology. https://doi.org/10.1080/01443615.2026.2697493

GB/T 7714

Jing Zhou, Ying Sun. Diagnostic value of serum miR-101-3p combined with Doppler ultrasound in polycystic ovarian syndrome: a retrospective study.[J]. Journal of obstetrics and gynaecology : the journal of the Institute of Obstetrics and Gynaecology, 2026 doi:10.1080/01443615.2026.2697493.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Journal of obstetrics and gynaecology : the journal of the Institute of Obstetrics and Gynaecology 的其他文献