[对具有两种支柱直径形态的Voronoi多孔结构的压缩力学性能差异的模拟研究]

[A simulation study on the differences in compressive mechanical properties of Voronoi porous structures with two strut-diameter morphologies].

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

基于Voronoi的非周期多孔结构类似于骨小梁,广泛应用于骨支架设计。为阐明支柱直径形貌对压缩力学性能的影响,构建了两种孔隙率相同的Voronoi多孔结构,即均匀支柱结构和非均匀支柱结构。采用有限元方法分析了其准静态压缩和压缩疲劳行为。结果表明,均匀支柱结构在线性弹性阶段具有更均匀的应力分布和更高的刚度。非均匀支柱结构在压缩破坏过程中表现出更高的承载能力和能量吸收。在压缩疲劳载荷下,均匀支柱结构通常表现出更长的疲劳寿命。均匀支柱结构适用于长期循环载荷和可控力学匹配条件下的植入支架和假体;非均匀丝径结构更适用于抗冲击和能量吸收缓冲条件下的应用。这些结果为不同服役需求下Voronoi仿生多孔结构的选择和优化提供了参考。

Abstract

Voronoi-based non-periodic porous structures resemble trabecular bone and are widely used in bone scaffold design. To clarify the influence of strut-diameter morphology on compressive mechanical properties, two Voronoi porous structures with identical porosity, namely uniform-strut and non-uniform-strut structures, were constructed. Their quasi-static compressive and compressive-fatigue behaviors were analyzed using the finite element method. The results showed that the uniform-strut structure had a more homogeneous stress distribution and higher stiffness in the linear elastic stage. The non-uniform-strut structure exhibited higher load-bearing capacity and energy absorption during compression failure. Under compressive fatigue loading, the uniform-strut structure generally showed a longer fatigue life. The uniform-strut structure is suitable for implant scaffolds and prostheses under the conditions of long-term cyclic loading and controllable mechanical matching; the non-uniform filament diameter structure is more suitable for applications under the conditions of impact resistance and energy absorption buffering. These results provide a reference for the selection and optimization of Voronoi biomimetic porous structures under different service requirements.

如何引用

AMA

Yutao Men, Tonghao Wang, Miaojie Wu, Chunqiu Zhang. [A simulation study on the differences in compressive mechanical properties of Voronoi porous structures with two strut-diameter morphologies].. Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi. 2026; doi:10.7507/1001-5515.202601066.

APA

Yutao Men, Tonghao Wang, Miaojie Wu, Chunqiu Zhang (2026). [A simulation study on the differences in compressive mechanical properties of Voronoi porous structures with two strut-diameter morphologies].. Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi. https://doi.org/10.7507/1001-5515.202601066

GB/T 7714

Yutao Men, Tonghao Wang, Miaojie Wu, Chunqiu Zhang. [A simulation study on the differences in compressive mechanical properties of Voronoi porous structures with two strut-diameter morphologies].[J]. Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2026 doi:10.7507/1001-5515.202601066.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi 的其他文献