湿式静电除尘器对气溶胶化甲型流感病毒收集效率的评估
Evaluation of the Collection Efficiency of a Wet-Type Electrostatic Precipitator for Aerosolized Influenza A Virus.
Evaluation of the Collection Efficiency of a Wet-Type Electrostatic Precipitator for Aerosolized Influenza A Virus.
空气传播病毒是传染病传播的关键驱动因素,凸显了公共卫生监测中可靠检测的重要性。由于大气中病毒浓度极低,具有高病毒采集效率的采样器至关重要。尽管已采用多种方法使用各种采样器评估采集效率,但尚未开发出标准化采样器。我们此前开发了一种湿式静电除尘器(WT-ESP),并成功从公共环境中采集到严重急性呼吸综合征冠状病毒2型。然而,其定量采集空气传播病毒的效率仍不明确。本研究旨在阐明WT-ESP的采集效率。我们通过两种不同方法评估采集效率:直接喷雾法,即将含病毒气溶胶直接喷入WT-ESP入口;间接喷雾法,即将气溶胶分散至封闭空间后使用采样器采集。直接喷雾测试的采集效率为20.1%–50.2%,而间接喷雾测试的采集效率低于12%。这些发现表明,与既往研究中撞击式采样器(impinger)的报道值相比,静电除尘具有提高采集效率的优势,并为直接和间接喷雾条件下的采集效率提供了初步认识,为弥合两种方法之间的差距提供了基础数据。
Airborne viruses are a key driver of infectious disease transmission, highlighting the importance of reliable detection in public health surveillance. As atmospheric viral concentrations are very low, a sampler with a high viral collection efficiency is essential. Although multiple approaches for evaluating collection efficiency have been applied using various samplers, no standardized sampler has yet been developed. We previously developed a wet-type electrostatic precipitator (WT-ESP) and successfully collected severe acute respiratory syndrome coronavirus 2 from the public environment. However, its efficiency for quantitative collection of airborne viruses remains unclear. This study aimed to clarify the collection efficiency of the WT-ESP. We evaluated collection efficiency via two different approaches: direct spray, where virus-containing aerosols were sprayed directly into the WT-ESP inlet, and indirect spray, where aerosols were dispersed into a closed space and then collected using the sampler. The direct spray tests achieved 20.1-50.2% collection efficiency, whereas the indirect spray test achieved an efficiency <12%. These findings highlight that electrostatic precipitation has an advantage of enhancing collection efficiency compared with values reported for impingers in previous studies and provide preliminary insights into the collection efficiencies under direct and indirect spray conditions, providing foundational data that bridge the gap between both methods.
Kazuya Nakamura, Takeshi Nagai, Hitoshi Ishiguro, Keiichi Kobayashi, Kazuhisa Nakagawa, Masahiro Okanojo, et al. Evaluation of the Collection Efficiency of a Wet-Type Electrostatic Precipitator for Aerosolized Influenza A Virus.. Microorganisms. 2026; doi:10.3390/microorganisms14081863.
Kazuya Nakamura, Takeshi Nagai, Hitoshi Ishiguro, Keiichi Kobayashi, Kazuhisa Nakagawa, Masahiro Okanojo, et al (2026). Evaluation of the Collection Efficiency of a Wet-Type Electrostatic Precipitator for Aerosolized Influenza A Virus.. Microorganisms. https://doi.org/10.3390/microorganisms14081863
Kazuya Nakamura, Takeshi Nagai, Hitoshi Ishiguro, Keiichi Kobayashi, Kazuhisa Nakagawa, Masahiro Okanojo, et al. Evaluation of the Collection Efficiency of a Wet-Type Electrostatic Precipitator for Aerosolized Influenza A Virus.[J]. Microorganisms, 2026 doi:10.3390/microorganisms14081863.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出