基于两阶段机器学习框架,利用常规计算机断层扫描对 future osteoporotic fractures 进行逐椎体预测
Per-Vertebra Prediction of Future Osteoporotic Fractures from Routine Computed Tomography Using a Two-Stage Machine Learning Framework.
Per-Vertebra Prediction of Future Osteoporotic Fractures from Routine Computed Tomography Using a Two-Stage Machine Learning Framework.
骨质疏松性椎体压缩骨折影响约四分之一的绝经后女性,并带来显著的疾病负担,然而双能X线吸收测定法(DXA)等成熟的临床工具仅能提供患者层面的风险,无法识别哪一具体椎体最可能发生骨折。因无关指征而进行的计算机断层扫描(CT)是机会性筛查中最广泛可用的三维基础数据,但已发表的椎体骨折风险机器学习模型几乎普遍在患者层面运作。本研究旨在开发并严格验证一套适用于常规临床腰椎CT和机会性腹部CT的逐椎体预测流程,两者均因与骨质疏松筛查无关的指征而采集。从单一学术中心组建了两个独立的回顾性队列:常规临床腰椎CT队列106例患者,产生478个可评估椎体;常规腹部CT队列126例患者,产生589个可评估椎体。使用TotalSegmentator v2自动分割椎体,并通过形态学腐蚀分离骨小梁核心。提取了505项符合影像生物标志物标准化倡议(Image Biomarker Standardisation Initiative)推荐的定量影像生物标志物,涵盖骨小梁密度、椎体形态测量、经典纹理、骨小梁网络结构、终板下脆弱性、低密度拓扑、径向异质性及邻近肌肉质量。患者内特征工程将输入池扩展至1293个情境描述符。在完全嵌套的留一患者交叉验证下评估了三个模型家族:ElasticNet逻辑回归、条件逻辑回归的softmax排序近似,以及将患者层面脆弱性评分与患者内椎体离群评分相结合的两阶段模型。采用患者层面自助重采样(2000次迭代)获得95%置信区间。在常规临床腰椎CT上,两阶段模型达到逐椎体AUC 0.750(95% CI 0.704至0.795)、F1为0.549、患者内一致性指数0.693、期望校准误差0.044、Hit@3为0.934。它是所评估模型中唯一返回校准概率的模型;softmax排序和ElasticNet基线的期望校准误差分别为0.232和0.218。在机会性腹部CT上,softmax排序模型给出AUC 0.672(95% CI 0.615至0.727)。入选的生物标志物以区域骨小梁密度和骨小梁网络结构为主;一个稳定的腰椎特征核心在100%的交叉验证折中进入模型,表明具有高可重复性。在原发性、非手术患者中,最接近的既往基于CT的逐椎体预测器(Muehlematter等,58例患者队列)报告的逐椎体AUC为0.64,这是当前结果的若干参照点之一。十项方法学变体和敏感性分析,包括秩融合、内部组织归一化和额外生物力学特征,未提供统计学显著增益,表明在此样本量下约束瓶颈是数据量而非方法学。两阶段分解将全身骨骼脆弱性与患者内椎体离群状态分离,从常规临床腰椎CT产生良好校准的逐椎体骨折风险估计,并且是所评估模型中唯一能做到这一点的模型,这使逐椎体输出能够作为绝对风险而非仅排序报告;对于机会性腹部CT,患者内排序模型更为可取。该分解相对于基线的区分优势在数值上一致但在此样本量下未达统计学确立,本工作作为逐椎体预测任务(仍属欠发展领域)透明且可重复的单中心基准呈现。其最明确的近期价值在于机会性应用,即在已因无关指征采集的CT上标记升高的逐椎体骨折风险,无需额外辐射、费用或专门的骨密度测定研究。外部多中心验证是必要的下一步。
Osteoporotic vertebral compression fractures affect approximately one in four postmenopausal women and carry substantial morbidity, yet established clinical tools such as dual-energy X-ray absorptiometry (DXA) provide only patient-level risk and do not identify which specific vertebra is most likely to fail. Computed tomography (CT) acquired for unrelated indications is the most widely available three-dimensional substrate for opportunistic screening, but published machine learning models for vertebral fracture risk almost universally operate at the patient level. The present study aimed to develop and rigorously validate a per-vertebra prediction pipeline applicable to both routine clinical lumbar-spine CT and opportunistic abdominal CT, both acquired for indications unrelated to osteoporosis screening. Two independent retrospective cohorts were assembled from a single academic centre: a routine clinical lumbar-spine CT cohort of 106 patients yielding 478 evaluable vertebrae, and a routine abdominal CT cohort of 126 patients yielding 589 evaluable vertebrae. Vertebral bodies were segmented automatically with TotalSegmentator v2 and the trabecular core isolated by morphological erosion. A panel of 505 quantitative imaging biomarkers compliant with Image Biomarker Standardisation Initiative recommendations was extracted, covering trabecular density, vertebral morphometry, classical texture, trabecular network architecture, sub-endplate vulnerability, low-density topology, radial heterogeneity and adjacent muscle quality. Within-patient feature engineering expanded the input pool to 1293 contextual descriptors. Three model families were evaluated under fully nested leave-one-patient-out cross-validation: ElasticNet logistic regression, a softmax-ranking approximation of conditional logistic regression, and a Two-Stage model combining a patient-level fragility score with a within-patient vertebral outlier score. Patient-level bootstrap resampling (2000 iterations) was used to obtain 95% confidence intervals. On routine clinical lumbar-spine CT the Two-Stage model achieved a per-vertebra AUC of 0.750 (95% CI 0.704 to 0.795), an F1 of 0.549, a within-patient concordance index of 0.693, an expected calibration error of 0.044, and Hit@3 of 0.934. It was the only model evaluated that returned calibrated probabilities; the softmax-ranking and ElasticNet baselines gave expected calibration errors of 0.232 and 0.218 respectively. On opportunistic abdominal CT, the softmax-ranking model gave AUC 0.672 (95% CI 0.615 to 0.727). Selected biomarkers were dominated by regional trabecular density and trabecular network architecture; a stable core of lumbar features entered the model in 100% of cross-validation folds, indicating high reproducibility. The closest prior per-vertebra CT-based predictor in primary, non-surgical patients (Muehlematter and colleagues, 58-patient cohort) reported a per-vertebra AUC of 0.64, which is one of several reference points for the present results. Ten methodological variants and sensitivity analyses, including rank fusion, internal tissue normalisation and additional biomechanical features, did not provide statistically significant gains, indicating that the binding constraint at this sample size is data volume rather than methodology. A two-stage decomposition that separates systemic skeletal fragility from within-patient vertebral outlier status produces well-calibrated per-vertebra fracture-risk estimates from routine clinical lumbar spine CT and was the only model evaluated to do so, which is what permits a per-vertebra output to be reported as an absolute risk rather than as an ordering alone; a within-patient ranking model is preferable for opportunistic abdominal CT. The discrimination advantage of the decomposition over that baseline is numerical and consistent but not statistically established at this sample size, and the work is presented as a transparent and reproducible single-centre benchmark for the still under-developed per-vertebra prediction task. Its clearest near-term value is opportunistic, namely flagging elevated per-vertebra fracture risk on CTs already acquired for unrelated indications without additional radiation, cost or a dedicated densitometric study. External multi-centre validation is the necessary next step.
Kirill Riazanovskiy, Dāvids Orlovs, Jekaterina Stepanova, Victor Sineglazov, Ardis Platkajis, Olena Chumachenko. Per-Vertebra Prediction of Future Osteoporotic Fractures from Routine Computed Tomography Using a Two-Stage Machine Learning Framework.. Medicina (Kaunas, Lithuania). 2026; doi:10.3390/medicina62081518.
Kirill Riazanovskiy, Dāvids Orlovs, Jekaterina Stepanova, Victor Sineglazov, Ardis Platkajis, Olena Chumachenko (2026). Per-Vertebra Prediction of Future Osteoporotic Fractures from Routine Computed Tomography Using a Two-Stage Machine Learning Framework.. Medicina (Kaunas, Lithuania). https://doi.org/10.3390/medicina62081518
Kirill Riazanovskiy, Dāvids Orlovs, Jekaterina Stepanova, Victor Sineglazov, Ardis Platkajis, Olena Chumachenko. Per-Vertebra Prediction of Future Osteoporotic Fractures from Routine Computed Tomography Using a Two-Stage Machine Learning Framework.[J]. Medicina (Kaunas, Lithuania), 2026 doi:10.3390/medicina62081518.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出