MR引导IMRT和VMAT技术用于早期声门癌的剂量学评估:一项初步比较计划研究。

Dosimetric Evaluation of MR-Guided IMRT and VMAT Techniques for Early-Stage Glottic Cancer: A Pilot Comparative Planning Study.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

早期声门癌由于喉部运动和邻近关键结构,需要高精度的放射治疗。磁共振引导放射治疗(MRgRT)能够实现实时可视化和运动管理,有望在减少治疗边界的同时改善剂量适形性。本初步比较计划研究比较了在Unity MR-linac上实施的MR引导调强放射治疗(IMRT)与为TrueBeam STx和Halcyon系统生成的容积旋转调强放疗(VMAT)计划的剂量学特征。纳入10例T1-T2N0声门鳞状细胞癌患者。为每例患者使用全部三种系统生成处方为42.5 Gy分5次照射的治疗计划。采用Friedman检验和事后Wilcoxon符号秩检验比较计划靶体积(PTV)覆盖、适形指数(CI)、均匀性指数(HI)、危及器官(OAR)剂量、机器跳数和出束时间。Unity实现了更优的剂量适形性(CI 0.97 ± 0.01,TrueBeam STx为0.78 ± 0.15,Halcyon为0.58 ± 0.19;< 0.001)和最高的平均剂量,而PTV覆盖(D95%和D98%)与TrueBeam STx相当且高于Halcyon。缩小治疗边界使PTV体积显著减小(11.09 ± 3.87 cm对17.43 ± 4.75 cm;= 0.0001)。Halcyon表现出最均匀的剂量分布(HI 7.88 ± 3.14),而TrueBeam STx显示中等均匀性(HI 12.81 ± 3.90)。大多数OAR剂量指标在各技术间相当,尽管部分喉部结构和食管存在显著差异。Unity的出束时间最长。MR引导IMRT提供了更优的剂量适形性,同时保持与TrueBeam STx相当的靶区覆盖,且OAR保护在临床可接受范围内。需要前瞻性临床研究来确定这些剂量学优势是否能转化为患者结局的改善。

Abstract

: Early-stage glottic cancer requires highly precise radiotherapy due to laryngeal motion and the proximity of critical structures. Magnetic resonance-guided radiotherapy (MRgRT) enables real-time visualization and motion management, potentially improving dose conformity while reducing treatment margins. This pilot comparative planning study compared the dosimetric characteristics of MR-guided intensity-modulated radiotherapy (IMRT) delivered on the Unity MR-linac with volumetric modulated arc therapy (VMAT) plans generated for the TrueBeam STx and Halcyon systems. : Ten patients with T1-T2N0 glottic squamous cell carcinoma were included. For each patient, treatment plans prescribing 42.5 Gy in five fractions were generated using all three systems. Planning target volume (PTV) coverage, conformity index (CI), homogeneity index (HI), organ-at-risk (OAR) doses, monitor units, and beam-on times were compared using Friedman and post hoc Wilcoxon signed-rank tests. : Unity achieved superior dose conformity (CI 0.97 ± 0.01 vs. 0.78 ± 0.15 for TrueBeam STx and 0.58 ± 0.19 for Halcyon; < 0.001) and the highest mean dose, while PTV coverage (D95% and D98%) was comparable to TrueBeam STx and higher than Halcyon. Reduced treatment margins resulted in significantly smaller PTV volumes (11.09 ± 3.87 cm vs. 17.43 ± 4.75 cm; = 0.0001). Halcyon demonstrated the most homogeneous dose distribution (HI 7.88 ± 3.14), whereas TrueBeam STx showed intermediate homogeneity (HI 12.81 ± 3.90). Most OAR dose metrics were comparable among techniques, although selected laryngeal structures and the esophagus differed significantly. Beam-on time was longest for Unity. : MR-guided IMRT provided superior dose conformity while maintaining target coverage comparable to TrueBeam STx with clinically acceptable OAR sparing. Prospective clinical studies are required to determine whether these dosimetric advantages translate into improved patient outcomes.

如何引用

AMA

Viktoras Rudžianskas, Evelina Jaselskė, Jurgita Laurikaitienė, Vita Šimonytė-Verbickienė, Diana Adlienė. Dosimetric Evaluation of MR-Guided IMRT and VMAT Techniques for Early-Stage Glottic Cancer: A Pilot Comparative Planning Study.. Medicina (Kaunas, Lithuania). 2026; doi:10.3390/medicina62081507.

APA

Viktoras Rudžianskas, Evelina Jaselskė, Jurgita Laurikaitienė, Vita Šimonytė-Verbickienė, Diana Adlienė (2026). Dosimetric Evaluation of MR-Guided IMRT and VMAT Techniques for Early-Stage Glottic Cancer: A Pilot Comparative Planning Study.. Medicina (Kaunas, Lithuania). https://doi.org/10.3390/medicina62081507

GB/T 7714

Viktoras Rudžianskas, Evelina Jaselskė, Jurgita Laurikaitienė, Vita Šimonytė-Verbickienė, Diana Adlienė. Dosimetric Evaluation of MR-Guided IMRT and VMAT Techniques for Early-Stage Glottic Cancer: A Pilot Comparative Planning Study.[J]. Medicina (Kaunas, Lithuania), 2026 doi:10.3390/medicina62081507.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Medicina (Kaunas, Lithuania) 的其他文献