一种基于3D多孔离子凝胶的宽范围高灵敏度柔性电容式压力传感器,用于可穿戴健康监测
A Flexible Capacitive Pressure Sensor with Broad-Range High Sensitivity Based on 3D Porous Ionogel for Wearable Health Monitoring.
A Flexible Capacitive Pressure Sensor with Broad-Range High Sensitivity Based on 3D Porous Ionogel for Wearable Health Monitoring.
具有高灵敏度、宽检测范围和优异稳定性的柔性压力传感器是高精度电子皮肤和人体健康监测的关键组件。为克服现有传感器在宽压力范围内保持高响应性方面的局限,本文开发了一种基于三维多孔离子凝胶泡沫复合材料(IL/EG/PVA@MF)并结合平面电极阵列的新型柔性电容式压力传感器。该器件利用三维超弹性三聚氰胺泡沫(MF)骨架的结构工程与多孔离子凝胶的压力调控边缘场分布及离子电子界面极化的协同作用。实验评估表明,该传感器实现了62.45 kPa⁻¹的高归一化灵敏度(2–10 kPa),并在0–50 kPa的宽工作范围内保持可靠的分段线性传感性能,响应时间快至8 ms以内。此外,该传感器在50 kPa下经过6000次压缩-释放循环后表现出优异的性能一致性,验证了其良好的机械耐久性。在实际应用中,该器件能够高保真地监测多种生理信号,从微弱的桡动脉脉搏到大幅度的关节运动和特定的咳嗽模式,凸显了其在集成可穿戴系统和智能医疗保健方面的广阔潜力。
Flexible pressure sensors featuring high sensitivity, a broad detection range, and excellent stability are pivotal components for high-precision electronic skins and human health monitoring. To circumvent the limitations of existing sensors in maintaining high responsiveness across extensive pressure ranges, herein, a novel flexible capacitive pressure sensor is developed based on a 3D porous ionogel foam composite (IL/EG/PVA@MF) coupled with a planar electrode array. This device leverages the synergistic structural engineering of the 3D hyperelastic melamine foam (MF) skeleton and the pressure-regulated fringe-field distribution and iontronic interfacial polarization of the porous ionogel. Experimental evaluations demonstrate that the sensor achieves a high normalized sensitivity of 62.45 kPa (2-10 kPa) and maintains reliable piecewise linear sensing performance across a broad working range of 0-50 kPa, accompanied by a rapid response time of within 8 ms. Furthermore, the sensor exhibits outstanding performance consistency after 6000 compression-release cycles at 50 kPa, verifying its good mechanical durability. In practical applications, the device can monitor diverse physiological signals with high fidelity, ranging from subtle radial artery pulses to large-scale joint movements and specific coughing patterns, underscoring its broad potential for integrated wearable systems and intelligent healthcare.
Yi Chen, Xuedan Xie, Yonghua Wang, Dan Liu. A Flexible Capacitive Pressure Sensor with Broad-Range High Sensitivity Based on 3D Porous Ionogel for Wearable Health Monitoring.. Micromachines. 2026; doi:10.3390/mi17080983.
Yi Chen, Xuedan Xie, Yonghua Wang, Dan Liu (2026). A Flexible Capacitive Pressure Sensor with Broad-Range High Sensitivity Based on 3D Porous Ionogel for Wearable Health Monitoring.. Micromachines. https://doi.org/10.3390/mi17080983
Yi Chen, Xuedan Xie, Yonghua Wang, Dan Liu. A Flexible Capacitive Pressure Sensor with Broad-Range High Sensitivity Based on 3D Porous Ionogel for Wearable Health Monitoring.[J]. Micromachines, 2026 doi:10.3390/mi17080983.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出