基于人工智能的合成CT生成与自动分割在前列腺癌CBCT引导自适应放疗中的整合:一项可行性研究
Integration of AI-Based Synthetic CT Generation and Auto-Segmentation for CBCT-Guided Adaptive Radiotherapy in Prostate Cancer: A Feasibility Study.
Integration of AI-Based Synthetic CT Generation and Auto-Segmentation for CBCT-Guided Adaptive Radiotherapy in Prostate Cancer: A Feasibility Study.
自适应放疗(ART)在前列腺癌治疗中至关重要,但成本高昂。本研究旨在初步验证一套集成人工智能工作流程用于CBCT引导的前列腺癌自适应放疗的可行性,并为后续临床转化提供技术基础。研究使用120例患者的计划CT和CBCT图像进行训练和验证,另保留21例患者用于测试。采用CycleGAN-ResNet从CBCT生成合成CT(sCT),并利用nnU-Net模型在sCT上进行自动分割。对图像质量和分割准确性进行了定量评估。在sCT上重新计算原始计划以评估实际剂量投照;若临床约束条件未满足,则进行自适应再优化,并对计划进行比较。本研究每分次总时间约为19±6分钟,处于已报道的在线ART可行性范围内。sCT图像质量显著提高,适合后续自动分割和治疗计划制定。自动分割技术大幅提升了勾画效率,自动生成的轮廓仅需少量修改即可满足临床标准。在剂量学分析中,自适应计划提供了更优的靶区覆盖、适形指数(CI)和均匀性指数(HI)。与原始计划的实际投照剂量相比,自适应计划的膀胱V40更低,直肠平均剂量/V30/V40/V50也更低。本研究初步验证了一套集成AI工作流程的可行性,该流程串联了基于CycleGAN的sCT生成、基于nnU-Net的自动分割以及基于sCT的自适应计划再优化。与传统的分段研究相比,这一集成探索有助于更全面地评估AI技术在CBCT引导的前列腺癌ART中的潜在价值,为推广一种成本效益更佳的自适应放疗方法提供了初步解决方案。
: Adaptive radiotherapy (ART) is essential yet expensive in prostate cancer treatment. This study aims to preliminarily validate the feasibility of an integrated AI workflow for CBCT-guided adaptive radiotherapy in prostate cancer, and to provide a technical foundation for subsequent clinical translation. : Planning CT and CBCT images from 120 patients were used for training and validation, while 21 patients were reserved for testing. A CycleGAN-ResNet generated synthetic CT (sCT) from CBCT, and an nnU-Net model performed auto-segmentation on the sCT. Image quality and segmentation accuracy were quantitatively assessed. The original plan was recalculated on sCT to evaluate actual dose delivery; if clinical constraints were unmet, adaptive re-optimization was performed, and plans were compared. : The total time per fraction in this study was approximately 19 ± 6 min, falling within the reported feasibility range for online ART. sCT image quality was significantly improved, making them suitable for subsequent auto-segmentation and treatment planning. The auto-segmentation technique substantially enhanced contouring efficiency, with the automatically generated contours requiring only minor modifications to meet clinical standards. In dosimetric analysis, the adaptive plans provided superior target coverage, CI, and HI. Compared with the actual dose delivered by the original plan, the adaptive plans yielded lower bladder V40 and lower rectal mean dose/V30/V40/V50. : This study preliminarily validated the feasibility of an integrated AI workflow that concatenates CycleGAN-based sCT generation, nnU-Net-based auto-segmentation, and sCT-based adaptive plan re-optimization. Compared with conventional segmented studies, this integrated exploration facilitates a more comprehensive assessment of the potential value of AI technologies in CBCT-guided prostate cancer ART, offering a preliminary solution for promoting a cost-effective adaptive radiotherapy approach.
Xin Feng, Wenwen Zhang, Fukui Huan, Yuxiang Liu, Deqi Chen, Huan Chen, et al. Integration of AI-Based Synthetic CT Generation and Auto-Segmentation for CBCT-Guided Adaptive Radiotherapy in Prostate Cancer: A Feasibility Study.. Cancers. 2026; doi:10.3390/cancers18162607.
Xin Feng, Wenwen Zhang, Fukui Huan, Yuxiang Liu, Deqi Chen, Huan Chen, et al (2026). Integration of AI-Based Synthetic CT Generation and Auto-Segmentation for CBCT-Guided Adaptive Radiotherapy in Prostate Cancer: A Feasibility Study.. Cancers. https://doi.org/10.3390/cancers18162607
Xin Feng, Wenwen Zhang, Fukui Huan, Yuxiang Liu, Deqi Chen, Huan Chen, et al. Integration of AI-Based Synthetic CT Generation and Auto-Segmentation for CBCT-Guided Adaptive Radiotherapy in Prostate Cancer: A Feasibility Study.[J]. Cancers, 2026 doi:10.3390/cancers18162607.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出