一种冻干CHA-侧向流平台用于从L1CAM免疫捕获的小细胞外囊泡中即时检测阿尔茨海默病相关miR-106b-5p

A lyophilized CHA-lateral flow platform for point-of-care detection of miR-106b-5p from L1CAM-Immunocaptured small extracellular vesicles in Alzheimer's disease.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

阿尔茨海默病(AD)的早期无创诊断仍是一项重大的临床挑战。血液中由L1CAM免疫捕获的小细胞外囊泡(sEVs)所携带的微小RNA,尤其是miR-106b-5p,已成为AD有前景的候选生物标志物。然而,其检测需要灵敏、特异、稳定且适合即时检测(POC)应用的方法。催化发夹组装(CHA)结合侧流免疫分析(LFIA)提供了一种潜在的POC解决方案,但其实际应用受到“DNA呼吸”引起的高背景泄漏和探针稳定性差的限制。在此,我们提出了一种集成的POC平台,该平台将L1CAM阳性sEVs的免疫磁富集与一种新型“折叠-吸附-封闭-固定-冻干”(FABIL)工艺相结合,用于CHA探针的稳定化。FABIL工艺利用磁性氧化石墨烯(MGO)吸附并物理分离发夹探针(H1和H2),从而抑制非特异性杂交,并生成具有室温稳定性的冻干CHA微球。当整合到侧流试纸条中时,FABIL-NE-miR平台实现了10 fM的视觉检测限和1.14 fM的液相检测限,克服了低背景与高灵敏度之间的传统权衡。使用100份血清样本(包括32例AD病例和68例非AD对照)进行的临床验证表明,FABIL-NE-miR优于传统的低背景CHA系统,其ROC曲线下面积(AUC)为0.9563,灵敏度为90.63%,特异性为94.12%。总体而言,FABIL-NE-miR平台能够从L1CAM免疫捕获的sEV组分中快速可视化检测低丰度AD相关miRNA。通过解决背景泄漏和探针不稳定性等关键挑战,本研究为AD筛查提供了一种实用工具,并支持FABIL策略作为下一代核酸检测通用平台的可行性。

Abstract

The early, non-invasive diagnosis of Alzheimer's disease (AD) remains a significant clinical challenge. MicroRNAs carried by L1CAM-immunocaptured small extracellular vesicles (sEVs) in blood, particularly miR-106b-5p, have emerged as promising candidate biomarkers for AD. However, their detection requires methods that are sensitive, specific, stable, and suitable for point-of-care (POC) applications. Catalytic hairpin assembly (CHA) combined with lateral flow immunoassay (LFIA) offers a potential POC solution, but its practical application is limited by high background leakage caused by "DNA breathing" and poor probe stability. Herein, we propose an integrated POC platform that combines immunomagnetic enrichment of L1CAM-positive sEVs with a novel "Fold-Adsorb-Block-Immobilize-Lyophilize" (FABIL) process for CHA probe stabilization. The FABIL process utilizes magnetic graphene oxide (MGO) to adsorb and physically separate hairpin probes (H1 and H2), thereby suppressing nonspecific hybridization and generating lyophilized CHA microspheres with room-temperature stability. When integrated into a lateral flow test strip, the FABIL-NE-miR platform achieves a visual detection limit of 10 fM and a liquid-phase limit of detection of 1.14 fM, overcoming the traditional trade-off between low background and high sensitivity. Clinical validation using 100 serum samples, including 32 AD cases and 68 non-AD controls, demonstrated that FABIL-NE-miR outperformed traditional low-background CHA systems, with an area under the ROC curve (AUC) of 0.9563, a sensitivity of 90.63%, and a specificity of 94.12%. Overall, the FABIL-NE-miR platform enables rapid visual detection of low-abundance AD-associated miRNAs from L1CAM-immunocaptured sEV fractions. By addressing key challenges such as background leakage and probe instability, this study provides a practical tool for AD screening and supports the feasibility of the FABIL strategy as a universal platform for next-generation nucleic acid diagnostics.

如何引用

AMA

Ran Xu, Hao Chen, Chao Zhao, Xiqing Ding. A lyophilized CHA-lateral flow platform for point-of-care detection of miR-106b-5p from L1CAM-Immunocaptured small extracellular vesicles in Alzheimer's disease.. Analytica chimica acta. 2026; doi:10.1016/j.aca.2026.345938.

APA

Ran Xu, Hao Chen, Chao Zhao, Xiqing Ding (2026). A lyophilized CHA-lateral flow platform for point-of-care detection of miR-106b-5p from L1CAM-Immunocaptured small extracellular vesicles in Alzheimer's disease.. Analytica chimica acta. https://doi.org/10.1016/j.aca.2026.345938

GB/T 7714

Ran Xu, Hao Chen, Chao Zhao, Xiqing Ding. A lyophilized CHA-lateral flow platform for point-of-care detection of miR-106b-5p from L1CAM-Immunocaptured small extracellular vesicles in Alzheimer's disease.[J]. Analytica chimica acta, 2026 doi:10.1016/j.aca.2026.345938.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Analytica chimica acta 的其他文献