中心静脉导管异位导致化学性胸腔积液:病例报告

Misplaced Central Venous Catheter Leading to a Chemothorax: Case Report.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

中心静脉导管(CVC)置入是化疗给药的一种常见操作。不良事件包括导管位置异常或移位;关于植入式CVC位置异常的报道有限。一名59岁女性,近期诊断为转移性小细胞肺癌,有高血压病史,既往吸烟超过60包年,患有慢性阻塞性肺疾病但无慢性低氧性呼吸衰竭,在首次门诊化疗输注后就诊于急诊科。她出现急性起病的呼吸困难、中度呼吸窘迫和低氧血症。检查发现其锁骨下植入式(即“输液港”)CVC位置异常,该导管于一周前在透视引导下置入,并通过胸部X线片确认位置正确。评估显示大量右侧胸腔积液,继发于化疗药物意外胸腔内输注。患者被转送至三级医疗中心,经胸腔闭式引流管引流积液后临床状况成功改善。我们呈现一例罕见的因胸腔内中心静脉导管位置异常导致的化疗性胸腔积液,尽管X线片提示位置正确,且化疗输注引起了呼吸短促这一常见主诉。本病例凸显了影像学确认CVC位置的局限性以及位置异常所导致的并发症。

Abstract

The placement of central venous catheters (CVC) is a common procedure for the administration of chemotherapy. Adverse events include malposition or displacement; there are limited reports of misplaced implanted CVCs. A 59-year-old female with a history of recently diagnosed metastatic small cell lung cancer, hypertension, former tobacco use of over 60 pack-years, and chronic obstructive pulmonary disease without chronic hypoxemic respiratory failure presented to the emergency department following the first outpatient infusion of chemotherapy. She developed acute onset dyspnea, moderate respiratory distress, and hypoxemia. She was found to have a malpositioned subclavian implanted (ie, "port") CVC that was placed under fluoroscopy the week prior with placement confirmed by chest radiograph. The evaluation revealed a large right pleural effusion secondary to unintentional intrapleural infusion of chemotherapy. The patient was transferred to a tertiary-care center with successful clinical improvement after drainage of the effusion via tube thoracostomy. We present an uncommon diagnosis of a chemothorax from a malpositioned central venous catheter in the thorax, despite a radiograph suggesting correct placement, and infusion of chemotherapy causing a common complaint of shortness of breath. This case highlights the limitations of radiographic confirmation of CVCs and a resultant complication from malpositioning.

如何引用

AMA

Hannah E Miller, Skyler Lentz. Misplaced Central Venous Catheter Leading to a Chemothorax: Case Report.. Clinical practice and cases in emergency medicine. 2026; doi:10.5811/cpcem.62200.

APA

Hannah E Miller, Skyler Lentz (2026). Misplaced Central Venous Catheter Leading to a Chemothorax: Case Report.. Clinical practice and cases in emergency medicine. https://doi.org/10.5811/cpcem.62200

GB/T 7714

Hannah E Miller, Skyler Lentz. Misplaced Central Venous Catheter Leading to a Chemothorax: Case Report.[J]. Clinical practice and cases in emergency medicine, 2026 doi:10.5811/cpcem.62200.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Clinical practice and cases in emergency medicine 的其他文献