类风湿性关节炎中扭矩Teno病毒DNA定量的可重复性和输入减少的潜力
Reproducibility and Potential for Input Reduction for Torque Teno Virus DNA Quantification in Rheumatoid Arthritis.
Reproducibility and Potential for Input Reduction for Torque Teno Virus DNA Quantification in Rheumatoid Arthritis.
背景:细环病毒(Torque teno virus,TTV)是一种小型非致病性病毒,目前正在研究其作为潜在生物标志物,用于监测接受各种免疫抑制治疗的类风湿关节炎(rheumatoid arthritis,RA)患者的免疫能力。为便于对现有泛欧洲RA队列进行大规模评估,需要确定通过定量PCR(qPCR)检测TTV DNA所需的最小标本(血清)输入量,并明确其与免疫抑制类型和剂量的关系。方法:通过对来自接受不同治疗的RA患者的278份人血清样本进行1:1、1:2、1:4和1:8稀释,开展TTV qPCR分析。评估了最小可检测差异(smallest detectable difference,SSD)以及组内相关系数(intra-class correlation,ICC)。通过额外检测19份重复样本确定结果的可重复性。结果:RA患者血清显示平均TTV病毒载量相当于2.9 log10基因组拷贝/mL(SD ± 1.47)。共有32份样本(11.6%)TTV阴性;54份(19.6%)低于2.4 log10,即制造商的最低定量限;44份(16%)介于2.4和3.0 log10之间;145份(52.7%)显示高于3.0 log10的高病毒载量。稀释和重复实验显示TTV检测具有高稳定性和可重复性(总体ICC:0.95(95%CI:0.951至0.966))。TTV在未稀释与4倍稀释以及8倍稀释样本之间存在差异(1 vs. 2:= 0.993;1 vs. 4:< 0.001;1 vs. 8:< 0.001),与ICC降低和敏感性下降相一致。RA疾病活动度不影响可重复性。结论:对RA患者血清样本进行定量TTV DNA检测可获得高度可重复的结果,包括2倍稀释的血清样本。
: Torque teno virus (TTV) is small non-pathogenic virus, currently under investigation as a potential biomarker to monitor immunocompetence in patients with rheumatoid arthritis (RA) receiving various immunosuppressive therapies. To allow for large-scale assessment of existing pan-European RA cohorts, minimal specimen (serum) input for TTV DNA detection through quantitative PCR (qPCR) needs to be identified in relation to the type and quantity of immunosuppression. : TTV qPCR analysis was performed by measuring 1:1, 1:2, 1:4 and 1:8 dilutions of 278 human serum samples derived from patients with RA under different therapies. The smallest detectable difference (SSD) as well as the intra-class correlation (ICC) were assessed. The reproducibility of results was determined by measuring an additional 19 sample duplicates. : RA patient sera showed a mean TTV viral load equivalent of 2.9 log10 genome copies/mL (SD ± 1.47). A total of 32 samples (11.6%) were negative for TTV; 54 (19.6%) were below 2.4 log10, the manufacturer's lower limit of quantification; 44 (16%) were between 2.4 and 3.0 log10; and 145 (52.7%) showed a high viral load above 3.0 log10. Dilution and replication experiments showed a high stability and reproducibility of TTV measurements (overall ICC: 0.95 (95%CI: 0.951 to 0.966)). TTV differed between undiluted and 4-fold- as well as 8-fold-diluted samples (1 vs. 2: = 0.993; 1 vs. 4: < 0.001; 1 vs. 8: < 0.001), aligned with decreasing ICC and less sensitivity. RA disease activity did not influence reproducibility. : Quantitative TTV DNA detection in serum samples from RA patients yields highly reproducible results, including 2-fold-diluted serum samples.
Paul Studenic, Chaimae Akile, Claudia Anna Hana, Daniela Sieghart, Thi Lan Vi Tran, Josef Baliko, et al. Reproducibility and Potential for Input Reduction for Torque Teno Virus DNA Quantification in Rheumatoid Arthritis.. Medical sciences (Basel, Switzerland). 2026; doi:10.3390/medsci14040467.
Paul Studenic, Chaimae Akile, Claudia Anna Hana, Daniela Sieghart, Thi Lan Vi Tran, Josef Baliko, et al (2026). Reproducibility and Potential for Input Reduction for Torque Teno Virus DNA Quantification in Rheumatoid Arthritis.. Medical sciences (Basel, Switzerland). https://doi.org/10.3390/medsci14040467
Paul Studenic, Chaimae Akile, Claudia Anna Hana, Daniela Sieghart, Thi Lan Vi Tran, Josef Baliko, et al. Reproducibility and Potential for Input Reduction for Torque Teno Virus DNA Quantification in Rheumatoid Arthritis.[J]. Medical sciences (Basel, Switzerland), 2026 doi:10.3390/medsci14040467.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出