超声心输出量监测仪测定的血流动力学参数与小儿脓毒性休克患者血清肌钙蛋白I水平的相关性:一项前瞻性观察性研究
Correlation Between Hemodynamic Parameters Measured by Ultrasonic Cardiac Output Monitor and Serum Troponin I Levels in Pediatric Septic Shock Patients: A Prospective Observational Study.
Correlation Between Hemodynamic Parameters Measured by Ultrasonic Cardiac Output Monitor and Serum Troponin I Levels in Pediatric Septic Shock Patients: A Prospective Observational Study.
儿童脓毒性休克常合并心肌功能障碍和高死亡率。心肌肌钙蛋白I(cTnI)是心肌损伤的生物标志物,而超声心输出量监测仪(USCOM)可实现无创血流动力学评估。本研究旨在探讨儿童脓毒性休克中USCOM衍生的血流动力学参数与血清cTnI水平之间的相关性,并考察正性肌力药物治疗与肌钙蛋白水平的关联。本研究为前瞻性观察性研究,纳入2025年5月至9月期间万隆Hasan Sadikin医院收治的32例脓毒性休克患儿。于1、3、6、12和24小时进行连续USCOM测量,评估心脏指数(CI)、每搏输出量指数(SVI)、Smith-Madigan正性肌力指数(SMII)和体循环血管阻力指数(SVRI)。于6和24小时采用高灵敏度检测法测定血清cTnI水平。采用Spearman检验分析相关性,并应用多变量回归探讨独立关联。cTnI中位水平从6小时的71 pg/mL显著升高至24小时的201 pg/mL(p < 0.01)。SVI的早期变化(1-6小时)与6小时cTnI呈负相关(r = -0.409;p = 0.020)。1小时SMII与24小时cTnI呈正相关(r = 0.409;p = 0.025),而24小时SVI与24小时cTnI呈正相关(r = 0.387;p = 0.035)。正性肌力药物数量与6小时和24小时较高的cTnI水平均独立相关。儿童脓毒性休克最初24小时内血清cTnI水平升高,且与动态血流动力学变化相关。这些发现提示将连续肌钙蛋白测定与无创血流动力学监测相结合可能具有潜在价值。尚需更大样本队列的进一步研究以验证这些观察结果。
Pediatric septic shock is frequently associated with myocardial dysfunction and high mortality. Cardiac troponin I (cTnI) is a biomarker of myocardial injury, while the Ultrasonic Cardiac Output Monitor (USCOM) enables non-invasive hemodynamic assessment. This study aimed to explore the correlation between USCOM-derived hemodynamic parameters and serum cTnI levels in pediatric septic shock, and to examine the association of inotropic therapy with troponin levels. A prospective observational study was conducted in 32 pediatric patients with septic shock admitted to Hasan Sadikin Hospital, Bandung, between May and September 2025. Serial USCOM measurements were performed at 1, 3, 6, 12, and 24 hours to assess cardiac index (CI), stroke volume index (SVI), Smith-Madigan Inotropy Index (SMII), and systemic vascular resistance index (SVRI). Serum cTnI levels were measured at 6 and 24 hours using a high-sensitivity assay. Correlations were analyzed using Spearman's test, and multivariable regression was applied to explore independent associations. Median cTnI levels increased significantly from 71 pg/mL at 6 hours to 201 pg/mL at 24 hours (p < 0.01). Early changes in SVI (1-6 hours) were negatively correlated with cTnI at 6 hours (r = -0.409; p = 0.020). SMII at 1 hour was positively correlated with cTnI at 24 hours (r = 0.409; p = 0.025), while SVI at 24 hours showed a positive correlation with cTnI at 24 hours (r = 0.387; p = 0.035). The number of inotropic agents was independently associated with higher cTnI levels at both 6 and 24 hours. Serum cTnI levels increased during the first 24 hours of pediatric septic shock and were associated with dynamic hemodynamic changes. These findings suggest a potential role for integrating serial troponin measurement with non-invasive hemodynamic monitoring. Further studies with larger cohorts are needed to validate these observations.
Indra Sandinirwan, Dzulfikar Djalil Lukmanul Hakim, Sri Endah Rahayuningsih, Saptadi Yuliarto, Stanza Uga Peryoga. Correlation Between Hemodynamic Parameters Measured by Ultrasonic Cardiac Output Monitor and Serum Troponin I Levels in Pediatric Septic Shock Patients: A Prospective Observational Study.. Open access emergency medicine : OAEM. 2026; doi:10.2147/OAEM.S606300.
Indra Sandinirwan, Dzulfikar Djalil Lukmanul Hakim, Sri Endah Rahayuningsih, Saptadi Yuliarto, Stanza Uga Peryoga (2026). Correlation Between Hemodynamic Parameters Measured by Ultrasonic Cardiac Output Monitor and Serum Troponin I Levels in Pediatric Septic Shock Patients: A Prospective Observational Study.. Open access emergency medicine : OAEM. https://doi.org/10.2147/OAEM.S606300
Indra Sandinirwan, Dzulfikar Djalil Lukmanul Hakim, Sri Endah Rahayuningsih, Saptadi Yuliarto, Stanza Uga Peryoga. Correlation Between Hemodynamic Parameters Measured by Ultrasonic Cardiac Output Monitor and Serum Troponin I Levels in Pediatric Septic Shock Patients: A Prospective Observational Study.[J]. Open access emergency medicine : OAEM, 2026 doi:10.2147/OAEM.S606300.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出