血液透析通路中的地理遗漏和支架移植物再狭窄

Geographic miss and stent graft restenosis in hemodialysis access.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

覆膜支架广泛用于治疗功能不良的血液透析血管通路,但再狭窄仍然常见,其预测因素尚未完全明确。我们从一个前瞻性维护的数据库中分析了2018年至2022年间接受覆膜支架植入的203例独立患者。地理性遗漏(geographic miss)定义为病变覆盖不充分或支架尺寸选择欠佳;纵向地理性遗漏(longitudinal geographic miss, LGM)定义为支架任一端5 mm范围内残余狭窄>30%。结局为覆膜支架通畅性丧失和通路初级通畅性丧失,采用Kaplan-Meier分析和Cox回归模型进行评估。在203例患者中,81%为动静脉移植物,19%为动静脉内瘘。一年覆膜支架通畅率和通路初级通畅率分别为63.1%和22.7%。在主要探索性多变量模型中,LGM与覆膜支架通畅性丧失(HR 2.62,95% CI 1.34-5.12)和通路初级通畅性丧失(HR 2.76,95% CI 1.50-5.05)均相关。与通畅性结局相关的其他因素包括糖尿病、血栓形成表现、血管破裂或夹层、较小的支架直径和覆膜支架长度。在另一个经临床调整的模型中,LGM仍与两种结局相关。这些发现提示,LGM可能代表一个潜在可修改的操作目标,尽管仍需采用标准化影像随访的前瞻性研究和前瞻性验证。

Abstract

Stent grafts are widely used to treat dysfunctional hemodialysis vascular access, yet restenosis remains common and its predictors are incompletely understood. We analyzed 203 unique patients who underwent stent graft implantation between 2018 and 2022 from a prospectively maintained database. Geographic miss was defined as inadequate lesion coverage or suboptimal stent sizing; longitudinal geographic miss (LGM) was defined as residual stenosis >30% within 5 mm of either stent edge. The outcomes were loss of stent graft patency and access primary patency, assessed using Kaplan-Meier analysis and Cox regression models. Among 203 patients, 81% had arteriovenous grafts and 19% had arteriovenous fistulas. One-year stent graft patency and access primary patency were 63.1% and 22.7%, respectively. In the primary exploratory multivariable model, LGM was associated with both loss of stent graft patency (HR 2.62, 95% CI 1.34-5.12) and loss of access primary patency (HR 2.76, 95% CI 1.50-5.05). Other factors associated with patency outcomes included diabetes mellitus, thrombosis presentation, vessel rupture or dissection, smaller stent diameter, and stent graft length. LGM remained associated with both outcomes in an additional clinically adjusted model. These findings suggest that LGM may represent a potentially modifiable procedural target, although prospective studies with standardized imaging follow-up and prospective validation are needed.

如何引用

AMA

Cheng-Wei Lien, Ming-Chien Hsieh, Mu-Yang Hsieh, Meng-Kan Chen, Chih-Cheng Wu. Geographic miss and stent graft restenosis in hemodialysis access.. Renal failure. 2026; doi:10.1080/0886022X.2026.2717813.

APA

Cheng-Wei Lien, Ming-Chien Hsieh, Mu-Yang Hsieh, Meng-Kan Chen, Chih-Cheng Wu (2026). Geographic miss and stent graft restenosis in hemodialysis access.. Renal failure. https://doi.org/10.1080/0886022X.2026.2717813

GB/T 7714

Cheng-Wei Lien, Ming-Chien Hsieh, Mu-Yang Hsieh, Meng-Kan Chen, Chih-Cheng Wu. Geographic miss and stent graft restenosis in hemodialysis access.[J]. Renal failure, 2026 doi:10.1080/0886022X.2026.2717813.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Renal failure 的其他文献