一种基于紫外线和过硫酸铵介导甲状腺激素碘释放的改良MCT8干扰物非放射性筛选方法

A modified nonradioactive screening assay for MCT8 disruptors based on UV and ammonium persulfate-mediated iodide release from thyroid hormone.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

单羧酸转运蛋白8(MCT8)负责甲状腺激素(TH)的跨细胞膜转运,在TH跨越血脑屏障的过程中发挥关键作用。MCT8对TH调节的重要性体现于MCT8蛋白功能缺失个体所出现的先天性神经和躯体损伤。化学抑制MCT8可能干扰甲状腺信号传导。既往报道的MCT8介导三碘甲状腺原氨酸(T3)摄取检测方法依赖于高温过硫酸铵(APS)消化后的碘释放,而该过程可能因蒸发和塑料器皿降解而受到影响。我们评估了紫外线辅助APS消化作为加热替代方案的效果。使用商用紫外灯,比较了紫外或加热介导的MCT8检测的消化效率和检测性能。紫外处理40分钟与加热消化相当,产生的Z'因子、IC₅₀值和剂量-反应曲线均等效。更长时间的暴露并未改善检测性能,反而导致板体变色。采用40分钟紫外消化的检测对已知MCT8抑制剂溴磺酞(BSP)和硅黄酮(SC)所得结果与加热消化相当。其他参考化学品在40分钟紫外消化与90°C加热60分钟之间显示一致的结果。总之,紫外线辅助APS消化是一种可靠、更快速且温度更低的加热消化替代方案,适用于筛选可能干扰MCT8介导TH转运的化学品。

Abstract

The monocarboxylate transporter 8 (MCT8) transports thyroid hormone (TH) across cell membranes, and plays a critical role in transporting TH across the blood brain barrier. The importance of MCT8 for TH regulation demonstrated by the congenital neurological and physical impairment that occurs in individuals with a nonfunctional MCT8 protein. Chemical inhibition of MCT8 may disrupt thyroid signaling. Previous described assay of MCT8-mediated triiodothyronine (T3) uptake relied on iodide release following high-temperature ammonium persulfate (APS) digestion which may be compromised by evaporation and degradation of plasticware. We evaluated a UV-assisted APS digestion as an alternative to heating. Using a commercial UV lamp, digestion efficiency and assay performance were compared for UV or heat-mediated MCT8 assay. UV for 40 min was comparable to heat digestion and yielded equivalent Z' factors, IC₅₀ values, and dose-response curves. Longer exposure did not improve assay performance but caused plate discoloration. The assay using UV digestion for 40 min produced results comparable to those obtained with heat digestion for known MCT8 inhibitors bromosulfophthalein (BSP) and silychristin (SC). Additional reference chemicals showed consistent results between UV digestion for 40 min and heating at 90 °C for 60 min. In summary, UV-assisted APS digestion is a reliable, faster, and lower-temperature alternative to heat digestion for screening of chemicals that may disrupt MCT8-mediated TH transport.

如何引用

AMA

Hongyan Dong, Michael G Wade. A modified nonradioactive screening assay for MCT8 disruptors based on UV and ammonium persulfate-mediated iodide release from thyroid hormone.. Toxicology in vitro : an international journal published in association with BIBRA. 2026; doi:10.1016/j.tiv.2026.106296.

APA

Hongyan Dong, Michael G Wade (2026). A modified nonradioactive screening assay for MCT8 disruptors based on UV and ammonium persulfate-mediated iodide release from thyroid hormone.. Toxicology in vitro : an international journal published in association with BIBRA. https://doi.org/10.1016/j.tiv.2026.106296

GB/T 7714

Hongyan Dong, Michael G Wade. A modified nonradioactive screening assay for MCT8 disruptors based on UV and ammonium persulfate-mediated iodide release from thyroid hormone.[J]. Toxicology in vitro : an international journal published in association with BIBRA, 2026 doi:10.1016/j.tiv.2026.106296.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Toxicology in vitro : an international journal published in association with BIBRA 的其他文献