模型驱动发现高灵敏度纳米柱状NiO电化学葡萄糖传感器

Model-Driven Discovery of Highly Sensitive Nanocolumnar NiO Electrochemical Glucose Sensors.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

利用掠射角沉积(GLAD)技术制备的纳米结构NiO电极,因其高表面积和可调形貌,是非酶电化学葡萄糖传感的有前景的平台。在GLAD中,调节沉积角度和基底旋转速率可显著影响电化学性能;然而,针对特定应用场景确定最优GLAD结构在很大程度上仍依赖实验试错。本研究建立了一个多尺度建模框架,将GLAD薄膜生长过程与葡萄糖电氧化性能相关联,该框架结合了格点动力学蒙特卡罗(kMC)模拟、形貌表征以及耦合反应-扩散电化学模型。从kMC生成的结构中,在广泛的GLAD几何参数范围内(如斜柱、螺旋形和垂直纳米柱),量化了关键形貌特征,包括表面积、孔隙率和方向迂曲度。随后将这些特征纳入Ni基催化剂上葡萄糖电氧化的均质多孔电极模型。该模型阐明了表面积与传质之间的权衡如何决定电极灵敏度。我们确定以72.5°沉积的斜柱形貌为最大化葡萄糖电氧化的最优设计,并发现采用类似几何形貌制备的物理电极对葡萄糖的灵敏度比先前被认为最优的垂直柱形貌制备的电极高约25%(即1.38 mA/mM·cm vs 1.12 mA/mM·cm)。除葡萄糖外,该建模工作流程为设计GLAD制备的电极用于其他生物传感目标以及电化学应用(包括能量转换和制氢)提供了通用指导原则。

Abstract

Nanostructured NiO electrodes fabricated using glancing angle deposition (GLAD) are promising platforms for nonenzymatic electrochemical glucose sensing, owing to their high surface area and tunable morphology. With GLAD, adjusting the deposition angle and substrate rotation rate can significantly affect electrochemical performance; however, identifying optimal GLAD structures for specific use cases is still largely experimental, relying on trial and error. Here, we develop a multiscale modeling framework that links the GLAD film growth process to glucose electro-oxidation performance by combining on-lattice kinetic Monte Carlo (kMC) simulations with morphology characterization and a coupled reaction-diffusion electrochemical model. Key morphological features, including surface area, porosity, and directional tortuosities, are quantified from kMC-generated structures across a wide range of GLAD geometries, such as slanted posts, helical shapes, and vertical nanocolumns. These features are then incorporated into a homogenized porous electrode model for glucose electro-oxidation on Ni-based catalysts. The model clarifies how the trade-off between surface area and mass transport governs electrode sensitivity. We identify a slanted-post morphology deposited at 72.5° as the optimal design for maximizing glucose electro-oxidation, and we find that physical electrodes formed with similar geometries were approximately 25% more sensitive to glucose than those formed with the vertical post morphology previously considered to be the optimum (i.e., 1.38 mA/mM·cm vs 1.12 mA/mM·cm). Beyond glucose, this modeling workflow provides general guidelines for designing GLAD-fabricated electrodes for other biosensing targets and for electrochemical applications, including energy conversion and hydrogen generation.

如何引用

AMA

MohammadAli Maleki Bigdeli, Jennifer Bruce, Abebaw B Jemere, Kenneth D Harris, Wylie Stroberg. Model-Driven Discovery of Highly Sensitive Nanocolumnar NiO Electrochemical Glucose Sensors.. ACS engineering Au. 2026; doi:10.1021/acsengineeringau.6c00026.

APA

MohammadAli Maleki Bigdeli, Jennifer Bruce, Abebaw B Jemere, Kenneth D Harris, Wylie Stroberg (2026). Model-Driven Discovery of Highly Sensitive Nanocolumnar NiO Electrochemical Glucose Sensors.. ACS engineering Au. https://doi.org/10.1021/acsengineeringau.6c00026

GB/T 7714

MohammadAli Maleki Bigdeli, Jennifer Bruce, Abebaw B Jemere, Kenneth D Harris, Wylie Stroberg. Model-Driven Discovery of Highly Sensitive Nanocolumnar NiO Electrochemical Glucose Sensors.[J]. ACS engineering Au, 2026 doi:10.1021/acsengineeringau.6c00026.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI