基于自编码器的红外高光谱成像检测生物基质中的纳米塑料
Autoencoder-Based Detection of Nanoplastics in Biological Matrices via Infrared Hyperspectral Imaging.
Autoencoder-Based Detection of Nanoplastics in Biological Matrices via Infrared Hyperspectral Imaging.
中红外高光谱成像是用于微塑料和纳米塑料(MNPs)定性定量分析以及生物组织和复杂基质表征的新兴工具。检测生物材料中的MNPs对于评估毒理学和生态学影响具有特殊意义;然而,聚合物振动谱带与蛋白质、脂质及其他生物组分的振动谱带之间存在显著的光谱重叠,这使低水平MNPs的鉴定变得复杂。本研究采用基于自编码器的异常检测方法,从量子级联激光红外(QCL-IR)显微镜获取的红外光谱中学习生物基质信号的光谱特征。基于残差的异常映射保留了具有化学意义的光谱特征,能够以热图形式可视化二维和三维细胞培养模型中纳米塑料(NP)的蓄积情况。研究评估了全连接(FC)、卷积神经网络(CNN)和混合(CNN-FC)自编码器架构,其中FC和CNN-FC模型在生物基质准确重建与NP光谱特征保留之间取得了平衡。该方法能够检测约50 nm的塑料颗粒,当其以局部蓄积形式存在时,对应于干燥生物材料约1%(m/m)的含量,相当于约10个颗粒/μm的表面密度。这些结果表明,残差异常检测可将高光谱成像拓展至复杂生物介质中纳米级塑料蓄积的可视化,其浓度接近仪器检测限。
Mid-infrared hyperspectral imaging is an emerging tool for the qualitative and quantitative analysis of micro- and nanoplastics (MNPs) and for the characterization of biological tissues and complex matrices. Detecting MNPs in biological materials is of particular interest for assessing toxicological and ecological impacts; however, significant spectral overlap between polymer vibrational bands and those of proteins, lipids, and other biological components complicates identification at low MNP levels. In this work, an autoencoder-based anomaly detection approach is employed to learn the spectral characteristics of biological matrix signals from infrared spectra acquired with quantum cascade laser infrared (QCL-IR) microscopy. Residual-based anomaly mapping preserves chemically meaningful spectral features, enabling heatmap visualization of nanoscale plastic (NP) accumulation in two- and three-dimensional cell culture models. Fully connected (FC), convolutional neural network (CNN) and hybrid (CNN-FC) autoencoder architectures were evaluated, with FC and CNN-FC models providing a balance between accurate biological matrix reconstruction and preservation of NP spectral signatures. The method enabled detection of ∼50 nm plastic particles when present as localized accumulations corresponding to approximately 1% (m/m) of the dried biological material, equivalent to surface density on the order of 10 particles/μm. These results demonstrate that residual anomaly detection can extend hyperspectral imaging to visualize nanoscale plastic accumulations in complex biological media at concentrations approaching the instrumental detection limit.
Daniel Prezgot, Sadman Sakib, Maohui Chen, Adrian F Pegoraro, David Corriveau, Shan Zou. Autoencoder-Based Detection of Nanoplastics in Biological Matrices via Infrared Hyperspectral Imaging.. ACS measurement science au. 2026; doi:10.1021/acsmeasuresciau.6c00067.
Daniel Prezgot, Sadman Sakib, Maohui Chen, Adrian F Pegoraro, David Corriveau, Shan Zou (2026). Autoencoder-Based Detection of Nanoplastics in Biological Matrices via Infrared Hyperspectral Imaging.. ACS measurement science au. https://doi.org/10.1021/acsmeasuresciau.6c00067
Daniel Prezgot, Sadman Sakib, Maohui Chen, Adrian F Pegoraro, David Corriveau, Shan Zou. Autoencoder-Based Detection of Nanoplastics in Biological Matrices via Infrared Hyperspectral Imaging.[J]. ACS measurement science au, 2026 doi:10.1021/acsmeasuresciau.6c00067.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出