家庭腹膜透析患者安全量表(PD-PSS)的开发和心理测量测试

Development and Psychometric Testing of the Patient Safety Scale for Home Peritoneal Dialysis (PD-PSS).

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

居家腹膜透析治疗提供了更大的自主性和灵活性。然而,它也带来了独特的患者安全风险。尽管存在这些风险,目前尚无经过验证的工具来评估居家环境中的患者安全。旨在开发并验证一个评估腹膜透析(PD)中环境、行为及操作安全风险的量表。本研究在八家医院共600例患者中开展。条目生成基于文献回顾、临床指南、现有工具及专家咨询,初步形成50个条目的条目池。通过专家意见确立内容效度。最终分析样本被随机分为两个独立子样本:样本I(n=300)进行探索性因子分析,样本II(n=300)进行验证性因子分析。评估了内部一致性、重测信度以及聚合效度和区分效度。最终量表包含42个条目,分属四个因子:安全透析操作、感染预防与并发症监测、治疗随访与安全准备、跌倒预防与安全,共解释总方差的80.5%。验证性因子分析结果证实模型拟合良好(χ/df=2.487;CFI=0.968;RMSEA=0.035)。该量表表现出极佳的内部一致性(α=0.939)和较强的重测信度(ICC=0.938)。聚合效度和区分效度标准均得到满足。该量表是评估腹膜透析患者安全的有效且可靠的工具。它涵盖了与国际安全框架相一致的关键领域,可帮助临床医生识别安全风险、指导干预措施并改善居家透析的结局。

Abstract

Home-based peritoneal dialysis treatment offers greater autonomy and flexibility. However, it also introduces unique patient safety risks. Despite these risks, there is no validated tool to assess patient safety in home settings. To develop and validate a scale to assess environmental, behavioral, and procedural safety risks in peritoneal dialysis (PD). This study was conducted with 600 patients across eight hospitals. Item generation was informed by literature review, clinical guidelines, existing instruments, and expert consultation, resulting in an initial 50-item pool. Content validity was established through expert opinions. The final analytic sample was randomly divided into two independent subsamples: exploratory factor analysis was conducted with Sample I (n = 300), and confirmatory factor analysis was conducted with Sample II (n = 300). Internal consistency, test-retest reliability, and convergent and discriminant validity were evaluated. The final scale consisted of 42 items across four factors: Safe Dialysis Practices, Infection Prevention and Complication Monitoring, Treatment Follow-up and Safety Preparedness, and Fall Prevention and Safety, explaining 80.5% of the total variance. The CFA results confirmed good model fit (χ/df = 2.487; CFI = 0.968; RMSEA = 0.035). The scale demonstrated excellent internal consistency (α = 0.939) and strong test-retest reliability (ICC = 0.938). Convergent and discriminant validity criteria were satisfied. The scale is a valid and reliable instrument for assessing patient safety in peritoneal dialysis. It addresses critical domains aligned with international safety frameworks and can support clinicians in identifying safety risks, guiding interventions, and improving outcomes in home dialysis.

如何引用

AMA

Zehra Aydin, Arzu Kader Harmancı Seren. Development and Psychometric Testing of the Patient Safety Scale for Home Peritoneal Dialysis (PD-PSS).. Japan journal of nursing science : JJNS. 2026; doi:10.1111/jjns.70072.

APA

Zehra Aydin, Arzu Kader Harmancı Seren (2026). Development and Psychometric Testing of the Patient Safety Scale for Home Peritoneal Dialysis (PD-PSS).. Japan journal of nursing science : JJNS. https://doi.org/10.1111/jjns.70072

GB/T 7714

Zehra Aydin, Arzu Kader Harmancı Seren. Development and Psychometric Testing of the Patient Safety Scale for Home Peritoneal Dialysis (PD-PSS).[J]. Japan journal of nursing science : JJNS, 2026 doi:10.1111/jjns.70072.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Japan journal of nursing science : JJNS 的其他文献