使用基于IMU的运动学模型对卒中后日常上臂使用进行量化

Quantification of daily upper arm use after stroke using an IMU-based kinematic model.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

上肢(UL)功能障碍是脑卒中后最常见且最具致残性的后果之一,限制了个体的独立性和日常生活活动的执行能力。尽管康复的目标是减轻功能障碍并提高真实世界中的活动表现,但临床运动评估往往无法捕捉到上肢的自发性使用情况。临床环境中观察到的运动能力与日常生活活动的实际表现之间的这种差异,凸显了对客观、具有生态效度的监测工具的需求。可穿戴惯性测量单元(IMU)已成为量化真实世界上肢使用情况的可行方法;然而,对于脑卒中患者(PwS)活动测量所衍生的运动学指标,其临床可解释性和有效性仍尚未充分确立。评估三种由IMU衍生的上肢使用运动学指标在脑卒中患者(PwS)日常活动中的效用,并检验其与运动功能障碍临床评估之间的关联。十九名亚急性期脑卒中患者在康复医院日常日间活动中佩戴了五个IMU传感器。提取每侧手臂的三项运动学指标——腕部路径长度、累积肘关节角位移和运动空间体积——并组合为不对称指数。临床评估包括上肢Fugl-Meyer评估(FMA-UE)、Action Research Arm Test(ARAT)和握力。分析了不对称指数及其与临床测量指标的相关性。所有IMU衍生的指标在患侧手臂均较非患侧手臂显著降低(< 0.001)。不对称指数与临床功能障碍测量指标显示显著相关性,其中累积肘关节角位移表现出最强的关联,尤其是与ARAT评分。基于IMU的运动学指标有效捕捉了脑卒中患者日常上肢使用的减少,并显示出与临床功能障碍的关联。这些发现支持可穿戴传感器在量化日常手臂使用方面的潜力,可作为活动表现和恢复的具有生态效度的指标。

Abstract

Upper limb (UL) impairment is one of the most common and disabling consequences of stroke, limiting independence and the performance of daily activities. Although rehabilitation aims to reduce impairments and enhance real-world activity performance, clinical motor assessments often fail to capture spontaneous UL use. This discrepancy between motor capacity observed in clinical settings and actual performance of daily activities underscores the need for objective, ecologically valid monitoring tools. Wearable inertial measurement units (IMUs) have emerged as feasible methodology for quantifying real-world UL use; however, the clinical interpretability and validity of kinematic metrics derived from measures of activity in persons with stroke (PwS) remain insufficiently established. To evaluate the utility of three IMU-derived kinematic measures of UL use in persons with stroke (PwS) during routine daily activity and to examine their associations with clinical assessments of motor impairment. Nineteen individuals in the subacute stage after stroke wore five IMU sensors during routine daytime activities in a rehabilitation hospital. Three kinematic measures - wrist path length, cumulative elbow angular displacement, and movement space volume - were extracted for each arm and combined to asymmetry indices. Clinical assessments included the Fugl-Meyer Assessment for the upper extremity (FMA-UE), Action Research Arm Test (ARAT), and grip strength. Asymmetry indices and their correlations with clinical measures were analyzed. All IMU-derived measures were significantly reduced in the paretic arm compared with the non-paretic arm ( < 0.001). Asymmetry indices showed significant correlations with clinical impairment measures, with cumulative elbow angular displacement demonstrating the strongest association, particularly with ARAT scores. IMU-based kinematic measures effectively capture reduced daily UL use in PwS and demonstrate associations with clinical impairment. These findings support the potential of wearable sensors to quantify daily arm use as an ecologically valid indicator of activity performance and recovery.

如何引用

AMA

Noy Goldhamer, Yogev Koren, Tamar Mizrahi, Adi Lorber-Haddad, Reut Binyamin-Netser, Lior Shmuelof. Quantification of daily upper arm use after stroke using an IMU-based kinematic model.. Frontiers in neurology. 2026; doi:10.3389/fneur.2026.1860647.

APA

Noy Goldhamer, Yogev Koren, Tamar Mizrahi, Adi Lorber-Haddad, Reut Binyamin-Netser, Lior Shmuelof (2026). Quantification of daily upper arm use after stroke using an IMU-based kinematic model.. Frontiers in neurology. https://doi.org/10.3389/fneur.2026.1860647

GB/T 7714

Noy Goldhamer, Yogev Koren, Tamar Mizrahi, Adi Lorber-Haddad, Reut Binyamin-Netser, Lior Shmuelof. Quantification of daily upper arm use after stroke using an IMU-based kinematic model.[J]. Frontiers in neurology, 2026 doi:10.3389/fneur.2026.1860647.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Frontiers in neurology 的其他文献