首页 >
期刊导航 >
Talanta >
{"_":"基于CuS@Au异质结/TiC MXene的级联信号放大策略自供电传感器用于检测IgAN尿液miRNA-23b-3p。","sub":["3","2"]}
{"_":"基于CuS@Au异质结/TiC MXene的级联信号放大策略自供电传感器用于检测IgAN尿液miRNA-23b-3p。","sub":["3","2"]}
{"_":"A self-powered sensor with cascade signal amplification strategy based on CuS@Au heterojunctions/TiC MXene for detection of IgAN urinary miRNA-23b-3p.","sub":["3","2"]}
Siyao Song, Tiantian Sun, Kaixiang Ji, Qiang Ma
Talanta(塔兰塔)
2026-08-19
刊期 2027-02-01
IF: 6.100
Q1
PMID: 42623826
DOI: 10.1016/j.talanta.2026.130479
摘要(中文译文)
IgA肾病(IgAN)是一种常见的原发性肾小球疾病。然而,目前缺乏可靠的快速尿液检测方法来监测IgAN的疾病进展。本研究开发了一种新型生物燃料电池自供电传感器,以CuS@Au NP异质结作为发电单元,以TiC MXene作为级联放大单元,用于检测尿液中的miRNA-23b-3p。在该自供电传感系统中,CuS@Au NP异质结通过阳极上Au NPs的类葡萄糖氧化酶活性和CuS NPs的类过氧化物酶活性实现葡萄糖的级联催化。此外,在自供电传感系统中设计了催化发夹组装策略,用于miRNA-23b-3p的定量检测。随后将MXene与高导电性和优异赝电容特性相结合,可实现传感器中电荷的快速存储和释放,从而对开路电压(E)响应产生级联放大效应。因此,基于CuS@Au NP异质结/MXene的自供电传感器在1 pM至1 μM的miRNA-23b-3p范围内表现出良好的线性,检测限为0.74 pM。最后,该自供电传感器具有蓝牙连接和实时监测能力,为IgAN的无创、快速辅助诊断提供了一种新颖、可行的策略。结果表明,IgAN患者尿液中的miRNA-23b-3p水平显著低于健康对照者。
Abstract
IgA Nephropathy (IgAN) was a common primary glomerular disease. However, there was a lack of reliable rapid urine detection methods for monitoring the disease progression of IgAN. Herein, this study has developed a novel biofuel cell self-powered sensor based on CuS@Au NP heterojunction as power generation unit and TiC MXene as cascade amplification unit for the detection of miRNA-23b-3p in urine. In this self-powered sensing system, CuS@Au NP heterojunction achieved cascade catalysis of glucose through the Gox-like activity of Au NPs and the POD-like activity of CuS NPs on the anode. Furthermore, the catalytic hairpin assembly strategy was designed in the self-powered sensing system for the quantitative detection of miRNA-23b-3p. The subsequent conjugation of MXene with the high conductivity and excellent pseudocapacitive properties can realize the rapid charge storage and release in the sensor, which provided a cascade amplification effect on the open-circuit voltage (E) response. Therefore, the CuS@Au NP heterojunction/MXene-based self-powered sensor exhibited good linearity in the range of 1 pM to 1 μM of miRNA-23b-3p with a detection limit of 0.74 pM. Finally, this self-powered sensor with Bluetooth connectivity and real-time monitoring ability provided a novel, feasible strategy for non-invasive, rapid auxiliary diagnosis of IgAN. The results revealed that miRNA-23b-3p levels in urine from IgAN patients was significantly lower than that form healthy controls.
如何引用
AMASiyao Song, Tiantian Sun, Kaixiang Ji, Qiang Ma. {"_":"A self-powered sensor with cascade signal amplification strategy based on CuS@Au heterojunctions/TiC MXene for detection of IgAN urinary miRNA-23b-3p.","sub":["3","2"]}. Talanta. 2027; doi:10.1016/j.talanta.2026.130479.
APASiyao Song, Tiantian Sun, Kaixiang Ji, Qiang Ma (2027). {"_":"A self-powered sensor with cascade signal amplification strategy based on CuS@Au heterojunctions/TiC MXene for detection of IgAN urinary miRNA-23b-3p.","sub":["3","2"]}. Talanta. https://doi.org/10.1016/j.talanta.2026.130479
GB/T 7714Siyao Song, Tiantian Sun, Kaixiang Ji, Qiang Ma. {"_":"A self-powered sensor with cascade signal amplification strategy based on CuS@Au heterojunctions/TiC MXene for detection of IgAN urinary miRNA-23b-3p.","sub":["3","2"]}[J]. Talanta, 2027 doi:10.1016/j.talanta.2026.130479.
在 PubMed增强版 阅读全文
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出