EXPRESS:疑似猫传染性腹膜炎患猫的猫冠状病毒即时检测与外部参考实验室RT-qPCR检测的一致性
EXPRESS: Agreement between point-of-care and external reference laboratory RT-qPCR testing for feline coronavirus in cats with suspected feline infectious peritonitis.
EXPRESS: Agreement between point-of-care and external reference laboratory RT-qPCR testing for feline coronavirus in cats with suspected feline infectious peritonitis.
评估一种市售即时检测猫冠状病毒(FCoV)RT-qPCR试剂盒与外部实验室RT-qPCR检测在渗出型和非渗出型猫传染性腹膜炎(FIP)患猫,以及表现相似临床症状的其他疾病患猫中的一致性。经畜主同意,纳入疑似FIP的客户拥有猫。采集积液以及超声引导下肝脏、脾脏或肠系膜淋巴结细针穿刺(FNA)样本,分割后分别使用即时检测RT-qPCR和外部实验室RT-qPCR进行分析。FIP依据AAFP/EveryCat指南诊断。计算敏感性和阴性预测值,采用Cohen's kappa评估一致性,采用McNemar检验分析配对差异,并使用Pearson系数和配对t检验分析交叉点(Cp)值的相关性。共纳入100只猫(积液n=62,FNA n=38)。两种检测的总体一致性为中等至高度(κ=0.73),积液的符合率接近完美(κ=0.81),FNA的一致性较低(κ=0.61)。相对敏感性在积液中最高(即时检测98.1%,外部实验室92.3%),在FNA中较低(63.3%-64.5%),阴性预测值呈现相似趋势。两种检测的Cp值呈中度相关,平均差异较小(约1个循环)。即时检测FCoV RT-qPCR试剂盒是一种实用且可靠的工具,与外部参考实验室RT-qPCR检测具有很好的一致性。当无法获得积液时,FNA仍有应用价值,但假阴性风险较高,可能源于病毒载量低和分布不均。即时检测周转时间短,有助于及时进行临床决策,但结果必须结合临床表现和其他诊断综合解读。
To evaluate the agreement of a commercially available point-of-care FCoV RT-qPCR assay and external laboratories RT-qPCR testing in cats with effusive and non-effusive FIP, and in cats with other diseases presenting with similar clinical signs. Client-owned cats suspected of FIP were enrolled with owner consent. Effusions and ultrasound-guided fine-needle aspirates (FNAs) from liver, spleen, or mesenteric lymph nodes were collected, split, and analysed using both a point-of-care RT-qPCR and an external laboratory RT-qPCR. FIP was diagnosed based on AAFP/EveryCat guidelines. Sensitivity and negative predictive values were calculated, agreement assessed with Cohen's kappa, paired differences tested with McNemar's test, and correlation of crossing point (Cp) values analysed using Pearson's coefficient and paired t-tests. One hundred cats were included (effusions n = 62, FNAs n = 38). Overall agreement between assays was substantial (κ = 0.73), with near-perfect concordance for effusions (κ = 0.81) and lower agreement for FNAs (κ = 0.61). Relative sensitivity was highest in effusions (98.1% point-of-care, 92.3% external) and lower in FNAs (63.3-64.5%), with negative predictive values showing similar trends. Cp values were moderately correlated between assays, with minor mean differences (~1 cycle). The point-of-care FCoV RT-qPCR assay is a practical and reliable tool and shows very good agreement with external reference laboratory RT-qPCR testing. FNAs remain useful when effusions are unavailable but carry higher risk of false negatives likely due to low viral loads and heterogeneous distribution. Point-of-care testing offers rapid turnaround, supporting timely clinical decision-making, but results must be interpreted alongside clinical presentation and other diagnostics.
Marieke Knies, Nikki Hofman, Johanna Jackson-Onis, Els M Broens, Erik Teske. EXPRESS: Agreement between point-of-care and external reference laboratory RT-qPCR testing for feline coronavirus in cats with suspected feline infectious peritonitis.. Journal of feline medicine and surgery. 2026; doi:10.1177/1098612X261483596.
Marieke Knies, Nikki Hofman, Johanna Jackson-Onis, Els M Broens, Erik Teske (2026). EXPRESS: Agreement between point-of-care and external reference laboratory RT-qPCR testing for feline coronavirus in cats with suspected feline infectious peritonitis.. Journal of feline medicine and surgery. https://doi.org/10.1177/1098612X261483596
Marieke Knies, Nikki Hofman, Johanna Jackson-Onis, Els M Broens, Erik Teske. EXPRESS: Agreement between point-of-care and external reference laboratory RT-qPCR testing for feline coronavirus in cats with suspected feline infectious peritonitis.[J]. Journal of feline medicine and surgery, 2026 doi:10.1177/1098612X261483596.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出