优化NiFe-PBA纳米材料的组成,并通过褶皱Ce-MOF协同增强金纳米簇的电化学发光:S100B免疫测定的新策略

Optimization of the Composition of NiFe-PBA Nanomaterials and Synergistic Enhancement of Electrochemiluminescence from Gold Nanoclusters via Pleated Ce-MOF: A New Strategy for S100B Immunoassay.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

作为与脑梗死(CI)相关的血液生物标志物,S100钙结合蛋白B(S100B)的超灵敏检测对脑梗死的早期预警具有重要意义。电化学发光(ECL)技术因其高灵敏度和低背景噪声而具有巨大的应用潜力。然而,ECL应用的进一步拓展往往受限于其低效率。特别是金纳米簇(NCs)通常因其配体的振动和旋转运动而发生显著的非辐射衰减。调控金属有机框架结构并与共反应促进剂协同增强是克服这一性能瓶颈的有效策略。本研究构建了一种在发光体和共反应物两侧均具有双重增强效应的ECL体系。在发光体侧,将牛血清白蛋白(BSA)稳定的金纳米簇(BSA-AuNCs)负载于褶皱状Ce-MOF上(B-AuNCs/Ce-MOF),通过刚性化效应抑制非辐射衰减,使ECL效率达到BSA-AuNCs的1.73倍。在共反应物侧,设计NiFe-PBA纳米材料(Ni/Fe前驱体摩尔比为3:2)作为共反应促进剂。密度泛函理论(DFT)计算表明,以Ni/Fe前驱体比例3:2构建的模型对三乙胺(TEA)表现出最优的吸附能,吸附能为-0.432 eV。因此,B-AuNCs/Ce-MOF+NiFe-PBA体系的ECL效率达到BSA-AuNCs的2.12倍。基于该协同增强体系,实现了对脑梗死生物标志物S100B的超灵敏检测,线性范围为0.1 pg/mL-100 ng/mL,检出限为0.03 pg/mL(S/N = 3)。该方法还表现出优异的稳定性、重现性和选择性。该策略为急性脑梗死的早期诊断和精准检测提供了新途径。

Abstract

As a blood biomarker associated with cerebral infarction (CI), the ultrasensitive detection of S100 calcium-binding protein B (S100B) is of great significance for the early warning of CI. Electrochemiluminescence (ECL) technology holds tremendous application potential due to its high sensitivity and low background noise. However, the further expansion of ECL applications is often limited by low efficiency. In particular, gold nanoclusters (NCs) typically undergo significant nonradiative decay due to the vibrational and rotational motion of their ligands. Regulating the metal-organic frameworks structure and synergistically enhancing it with coreactant accelerators is an effective strategy to overcome this performance bottleneck. In this study, we constructed an ECL system with dual enhancement effects of emitter and coreactant sides. At the emitter side, bovine serum albumin (BSA)-stabilized AuNCs (BSA-AuNCs) were loaded onto pleated Ce-MOF (B-AuNCs/Ce-MOF), and nonradiative decay was suppressed through the rigidification effect, resulting in 1.73 times the ECL efficiency of BSA-AuNCs. At the coreactant side, NiFe-PBA nanomaterials (Ni/Fe precursor molar ratio of 3:2) were engineered to serve as coreactant accelerators. Density functional theory (DFT) calculations indicated that the model constructed with a Ni/Fe precursor ratio of 3:2 exhibited the most favorable adsorption energy of TEA, with an adsorption energy of -0.432 eV. Consequently, the B-AuNCs/Ce-MOF+NiFe-PBA system exhibited 2.12 times the ECL efficiency of BSA-AuNCs. Based on this synergistically enhanced system, ultrasensitive detection of the CI biomarker S100B was achieved, with a linear range of 0.1 pg/mL-100 ng/mL and a detection limit of 0.03 pg/mL (S/N = 3). The method also demonstrated excellent stability, reproducibility and selectivity. This strategy provides a new approach for the early diagnosis and precise detection of acute CI.

如何引用

AMA

Na Li, Jingui Chen, Dehao Jia, Yu Du, Xiang Ren, Yueyun Li, et al. Optimization of the Composition of NiFe-PBA Nanomaterials and Synergistic Enhancement of Electrochemiluminescence from Gold Nanoclusters via Pleated Ce-MOF: A New Strategy for S100B Immunoassay.. Analytical chemistry. 2026; doi:10.1021/acs.analchem.6c03388.

APA

Na Li, Jingui Chen, Dehao Jia, Yu Du, Xiang Ren, Yueyun Li, et al (2026). Optimization of the Composition of NiFe-PBA Nanomaterials and Synergistic Enhancement of Electrochemiluminescence from Gold Nanoclusters via Pleated Ce-MOF: A New Strategy for S100B Immunoassay.. Analytical chemistry. https://doi.org/10.1021/acs.analchem.6c03388

GB/T 7714

Na Li, Jingui Chen, Dehao Jia, Yu Du, Xiang Ren, Yueyun Li, et al. Optimization of the Composition of NiFe-PBA Nanomaterials and Synergistic Enhancement of Electrochemiluminescence from Gold Nanoclusters via Pleated Ce-MOF: A New Strategy for S100B Immunoassay.[J]. Analytical chemistry, 2026 doi:10.1021/acs.analchem.6c03388.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Analytical chemistry 的其他文献