人工智能辅助锥形束CT分析预测下颌阻生第三磨牙与下牙槽神经邻近关系的验证:一项诊断准确性研究

Validation of artificial intelligence-assisted CBCT analysis for predicting inferior alveolar nerve proximity to impacted mandibular third molars: a diagnostic accuracy study.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

本研究旨在评估人工智能(AI)辅助锥形束计算机断层扫描(CBCT)分析系统预测下牙槽神经(IAN)与阻生下颌第三磨牙(M3M)空间邻近关系的诊断准确性,以专家放射科医师评估作为参考标准。本研究为回顾性诊断准确性研究,基于机构内312例患者队列(平均年龄28.21±6.62岁;2021年1月至2024年12月)。采用改进U-Net架构的深度学习系统在CBCT上自动分割下牙槽神经管和下颌第三磨牙,并将IAN-M3M空间关系分为三类:无接触(>2 mm)、邻近(0-2 mm)和接触/重叠。在包含486个M3位点(283例患者)的独立留出测试集上评估诊断准确性。两名资深口腔颌面放射科医师提供参考标准。计算敏感度、特异度、阳性预测值(PPV)、阴性预测值(NPV)、曲线下面积(AUC)和Cohen's kappa系数;95%置信区间(CI)分别采用Wilson评分法(比例)和bootstrap重采样(AUC、kappa)得出。AI系统总体准确率为90.1%(438/486;95% CI:87.1-92.5%),加权AUC为0.925(95% CI:0.904-0.944),Cohen's κ为0.851(95% CI:0.821-0.912),表明与专家参考标准几乎完全一致。各类别敏感度范围为88.2%至91.2%,特异度范围为92.8%至97.4%。Bland-Altman分析显示平均差异为0.06 mm(95%一致性界限:-0.63至0.75 mm)。IAN管分割的平均DSC为0.90±0.04,M3M分割为0.93±0.03。AI处理时间为4.75±1.12秒,专家评估为189.12±41.99秒(减少39.79倍;P<0.001)。亚组分析显示近中阻生(93.1%)和水平阻生(91.6%)准确率最高。该AI辅助CBCT分析系统在预测下牙槽神经与阻生下颌第三磨牙邻近关系方面表现出高诊断准确性和与专家放射学评估的极佳一致性,同时大幅缩短了处理时间。这些结果支持AI驱动的自动化CBCT分析作为术前决策支持工具的潜力;然而,参考标准为影像学而非术中评估,在提出明确的临床部署建议之前,尚需纳入手术结局数据的前瞻性多中心验证。

Abstract

This study aimed to evaluate the diagnostic accuracy of an artificial intelligence (AI)-assisted cone-beam computed tomography (CBCT) analysis system for predicting the spatial proximity of the inferior alveolar nerve (IAN) to impacted mandibular third molars (M3M), using expert radiologist assessment as the reference standard. A retrospective diagnostic accuracy study was conducted on an internal institutional cohort of 312 patients (mean age 28.21 �� 6.62 years; January 2021-December 2024). A deep learning system employing a modified U-Net architecture automatically segmented the IAN canal and M3M on CBCT and classified the IAN-M3M spatial relationship into three categories: no contact (> 2 mm), proximity (0-2 mm), and contact/overlap. Diagnostic accuracy was evaluated on an independent hold-out test set of 486 M3 sites (283 patients). Two senior oral and maxillofacial radiologists provided the reference standard. Sensitivity, specificity, PPV, NPV, AUC, and Cohen's kappa were calculated; 95% CIs were derived by Wilson score method (proportions) and bootstrap resampling (AUC, kappa). The AI system achieved an overall accuracy of 90.1% (438/486; 95% CI: 87.1-92.5%), weighted AUC of 0.925 (95% CI: 0.904-0.944), and Cohen's κ of 0.851 (95% CI: 0.821-0.912), indicating almost perfect agreement with the expert reference standard. Per-category sensitivity ranged from 88.2% to 91.2% and specificity from 92.8% to 97.4%. Bland-Altman analysis revealed a mean difference of 0.06 mm (95% LoA: -0.63 to 0.75 mm). Mean DSC was 0.90 ± 0.04 for IAN canal and 0.93 ± 0.03 for M3M segmentation. AI processing time was 4.75 ± 1.12 s versus 189.12 ± 41.99 s for expert assessment (39.79-fold reduction; P < 0.001). Subgroup analysis showed highest accuracy for mesioangular (93.1%) and horizontal (91.6%) impaction. The AI-assisted CBCT analysis system demonstrated high diagnostic accuracy and excellent agreement with expert radiological assessment in predicting IAN proximity to impacted mandibular third molars, while substantially reducing processing time. These results support the potential of AI-driven automated CBCT analysis as a preoperative decision-support tool; however, the reference standard was radiographic rather than intraoperative, and prospective multicenter validation incorporating surgical outcome data will be required before definitive clinical deployment recommendations can be made.

如何引用

AMA

Huan Hu, Jiahang Wu, Hongji Pu, Jichao Liang, Yan Niu, Jianghui Li, et al. Validation of artificial intelligence-assisted CBCT analysis for predicting inferior alveolar nerve proximity to impacted mandibular third molars: a diagnostic accuracy study.. BMC oral health. 2026; doi:10.1186/s12903-026-08690-z.

APA

Huan Hu, Jiahang Wu, Hongji Pu, Jichao Liang, Yan Niu, Jianghui Li, et al (2026). Validation of artificial intelligence-assisted CBCT analysis for predicting inferior alveolar nerve proximity to impacted mandibular third molars: a diagnostic accuracy study.. BMC oral health. https://doi.org/10.1186/s12903-026-08690-z

GB/T 7714

Huan Hu, Jiahang Wu, Hongji Pu, Jichao Liang, Yan Niu, Jianghui Li, et al. Validation of artificial intelligence-assisted CBCT analysis for predicting inferior alveolar nerve proximity to impacted mandibular third molars: a diagnostic accuracy study.[J]. BMC oral health, 2026 doi:10.1186/s12903-026-08690-z.