基于两台摄像机的乒乓球三维无标记动作捕捉准确性评估:一项初步研究
Evaluating the accuracy of table tennis 3D markerless motion capture based on two video cameras: a pilot study.
Evaluating the accuracy of table tennis 3D markerless motion capture based on two video cameras: a pilot study.
本初步研究提出了一种基于OpenPose框架和线性三角剖分的双目相机无标记乒乓球三维动作捕捉系统,用于获取三维关节运动数据。将该系统的精度与基于标记的系统进行了比较,并考察了不同相机配置的影响。研究开展了所提出的无标记系统与基于标记的参考系统之间的对比实验,测试了三种相机配置:RR-100(右侧-右侧放置,基线100 cm)、RR-145(右侧-右侧放置,基线145 cm)和RF-100(右侧-前方放置,基线100 cm)。以肘关节角度曲线的动态时间规整(DTW)相似度作为主要精度指标,并进行统计比较(p值)以识别不同配置下系统误差的显著差异。(1)在RR-100相机位置下,无标记系统与基于标记系统之间肘关节角度曲线的DTW相似度分别为0.941、0.719和0.854,与基于标记的系统相近。RR-145的DTW相似度达到0.948、0.730和0.887,RF-100为0.949、0.729和0.860。(2)在L = RR条件下,不同基线距离之间系统误差存在显著差异,145 cm时精度更优(p < 0.01)。(3)在L = RF且基线为100 cm条件下,误差存在显著差异,RF位置精度更优(p < 0.01)。(1)无标记系统虽然精度略低,但同样能够捕捉关节运动数据。(2)当相机位置固定时,增加基线距离可提高精度。(3)在基线距离固定的情况下,RF相机位置系统的精度优于RR位置。
This pilot study presents a 3D markerless motion capture system for table tennis using binocular cameras, based on the OpenPose framework and linear triangulation to obtain 3D joint motion data. The system's accuracy was compared to a marker-based system, and the impact of different camera. A comparative experiment was conducted between the proposed markerless system and a marker-based reference system. Three camera configurations were tested: RR-100 (right-right placement, 100 cm baseline), RR-145 (right-right placement, 145 cm baseline), and RF-100 (right-front placement, 100 cm baseline). Dynamic Time Warping (DTW) similarity of elbow joint angle curves was used as the primary accuracy metric, and statistical comparisons (p-values) were performed to identify significant differences in system errors across configurations. (1) At a camera position of RR-100, the DTW similarity of the elbow joint angle curves between the markerless and marker-based systems was 0.941, 0.719, and 0.854, respectively, similar to the marker-based system. The DTW similarity reached 0.948, 0.730, and 0.887 for RR-145 and 0.949, 0.729, and 0.860 for RF-100. (2) Significant differences in system errors were found at varying baseline distances with L = RR, showing better accuracy at 145 cm (p < 0.01). (3) Significant differences in errors were found with L = RF and a 100 cm baseline, with better accuracy at RF (p < 0.01). (1) The markerless system, though slightly less accurate, can also capture joint motion data. (2) Increasing baseline distance improves accuracy when the camera position is fixed. (3) With a fixed baseline distance, the system with the RF camera position outperforms the RR position in accuracy.
Ziwei Cao, Zikang Zhang, Yi Xiao. Evaluating the accuracy of table tennis 3D markerless motion capture based on two video cameras: a pilot study.. Frontiers in bioengineering and biotechnology. 2026; doi:10.3389/fbioe.2026.1854164.
Ziwei Cao, Zikang Zhang, Yi Xiao (2026). Evaluating the accuracy of table tennis 3D markerless motion capture based on two video cameras: a pilot study.. Frontiers in bioengineering and biotechnology. https://doi.org/10.3389/fbioe.2026.1854164
Ziwei Cao, Zikang Zhang, Yi Xiao. Evaluating the accuracy of table tennis 3D markerless motion capture based on two video cameras: a pilot study.[J]. Frontiers in bioengineering and biotechnology, 2026 doi:10.3389/fbioe.2026.1854164.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出