牛颈静脉与尾骨穿刺部位血液学测量的一致性研究

Agreement of Hematologic Measurements Between Jugular and Coccygeal Puncture Sites in Cattle.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

在牛医学中,静脉穿刺通常在颈静脉或尾静脉进行。尽管出于实际操作考虑,尾静脉部位常被优先选择,但科学研究中采样部位的标准并不统一。因此,确定从这两个部位获得的血液学指标是否可视为可互换十分重要。旨在评估牛配对颈静脉与尾静脉血样所获血液学指标在统计学和临床上的一致性。从48头成年奶牛采集配对的颈静脉和尾静脉血样,并使用自动血液分析仪、微量血细胞比容测定和血涂片评估进行分析。采用Pearson和Lin相关系数、Passing-Bablok回归和Bland-Altman分析评估两个采样部位之间的一致性,并根据已发表的总允许误差(TEa)阈值评估临床相关性。大多数血液学指标在颈静脉与尾静脉采样部位之间显示出良好的一致性。然而,血小板计数、红细胞压积(PCV)以及血涂片上某些手工白细胞分类计数,尤其是中性粒细胞和淋巴细胞,一致性较差,不应视为可互换。颈静脉与尾静脉穿刺部位对大多数自动化检测指标产生的血液学结果基本可比。然而,血小板指标、红细胞压积以及血涂片上的手工白细胞分类,尤其是中性粒细胞和淋巴细胞,在部位之间显示出较大变异性,不应视为可互换。在临床环境中,当将结果与参考区间比较或用于纵向监测时,建议始终一致地使用并记录穿刺部位,且对这些变量应应用使用相同采样部位建立的参考区间。

Abstract

In bovine medicine, venipuncture is commonly performed at either the jugular or coccygeal vein. Although the coccygeal site is often preferred for practical reasons, sampling sites are inconsistently standardized in scientific studies. It is therefore important to determine whether hematologic values obtained from these two sites can be considered interchangeable. To evaluate the statistical and clinical concordance of hematologic measurands obtained from paired jugular and coccygeal blood samples in cattle. Paired jugular and coccygeal blood samples were collected from 48 adult cows and analyzed using an automated hematology analyzer, micro-hematocrit determination, and blood smear evaluation. Agreement between sites was assessed using Pearson and Lin's correlation coefficients, Passing-Bablok regression, and Bland-Altman analysis, with clinical relevance evaluated against published total allowable error (TEa) thresholds. Most hematologic measurands showed good agreement between jugular and coccygeal sampling sites. However, platelet counts, packed cell volume (PCV), and certain manual leukocyte differential counts on blood smears, particularly neutrophils and lymphocytes, demonstrated poorer agreement and should not be considered interchangeable. Jugular and coccygeal puncture sites yield largely comparable hematologic results for most automated measurands. However, platelet indices, packed cell volume, and manual leukocyte differentials on blood smears, particularly neutrophils and lymphocytes, show greater variability between sites and should not be considered interchangeable. In clinical settings, when results are compared with reference intervals or used for longitudinal monitoring, consistent use and documentation of the puncture site are recommended, and reference intervals established using the same sampling site should be applied for these variables.

如何引用

AMA

Sophie Clouard, Camille Remuzat, Thomas Chetot. Agreement of Hematologic Measurements Between Jugular and Coccygeal Puncture Sites in Cattle.. Veterinary clinical pathology. 2026; doi:10.1111/vcp.70144.

APA

Sophie Clouard, Camille Remuzat, Thomas Chetot (2026). Agreement of Hematologic Measurements Between Jugular and Coccygeal Puncture Sites in Cattle.. Veterinary clinical pathology. https://doi.org/10.1111/vcp.70144

GB/T 7714

Sophie Clouard, Camille Remuzat, Thomas Chetot. Agreement of Hematologic Measurements Between Jugular and Coccygeal Puncture Sites in Cattle.[J]. Veterinary clinical pathology, 2026 doi:10.1111/vcp.70144.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Veterinary clinical pathology 的其他文献